Javascript must be enabled to continue!
A simple and precise calibration method for binocular vision
View through CrossRef
Abstract
Binocular vision is an important part of machine vision measurement. Calibration accuracy is crucial for binocular vision. As for the determination of the structure parameters of the two cameras, the existing approaches usually obtain the initial values and optimize them according to the image-space errors, object-space errors or a combination of these. In the optimization process, constructing the objective function only through the image-space errors or object-space errors is not enough. Moreover, the image-space and object-space errors can form a variety of combinations to construct the objective function. Therefore, it is hard to choose the error criterion. An inadequate error criterion may lead to over-optimized or local minima (ambiguity solution). To solve this problem, this paper proposes a simple and precise calibration method for binocular vision based on the points distance constraints and image-space errors. The process of determining the structure parameters was divided into noniterative and iterative parts. We calculated the structure parameters of the two cameras according to the distance constraints of every two feature points noniteratively. The results obtained in this step were set as the initial value and refined through minimizing the reprojection errors using the Levenberg–Marquardt method. Because the results obtained in the noniterative step are accurate enough, only one iteration is needed. In this way, we finish the calibration avoiding the need to choose the error criterion. Furthermore, our method reduces the number of iterations to improve the calibration efficiency on the premise of guaranteeing the calibration accuracy. The experimental results show the superiority of this calibration method compared with other calibration methods. Using the calibration results of our method, in the measurement range of −45°∼ 45°, the rotation angle measurement error was less than ±0.032°. In the measurement range of 0 ∼ 39 mm, the displacement measurement error was less than ±0.047 mm. As for the length measurement of a 300 × 225 mm target, the length measurement error was less than ±0.039 mm.
IOP Publishing
Title: A simple and precise calibration method for binocular vision
Description:
Abstract
Binocular vision is an important part of machine vision measurement.
Calibration accuracy is crucial for binocular vision.
As for the determination of the structure parameters of the two cameras, the existing approaches usually obtain the initial values and optimize them according to the image-space errors, object-space errors or a combination of these.
In the optimization process, constructing the objective function only through the image-space errors or object-space errors is not enough.
Moreover, the image-space and object-space errors can form a variety of combinations to construct the objective function.
Therefore, it is hard to choose the error criterion.
An inadequate error criterion may lead to over-optimized or local minima (ambiguity solution).
To solve this problem, this paper proposes a simple and precise calibration method for binocular vision based on the points distance constraints and image-space errors.
The process of determining the structure parameters was divided into noniterative and iterative parts.
We calculated the structure parameters of the two cameras according to the distance constraints of every two feature points noniteratively.
The results obtained in this step were set as the initial value and refined through minimizing the reprojection errors using the Levenberg–Marquardt method.
Because the results obtained in the noniterative step are accurate enough, only one iteration is needed.
In this way, we finish the calibration avoiding the need to choose the error criterion.
Furthermore, our method reduces the number of iterations to improve the calibration efficiency on the premise of guaranteeing the calibration accuracy.
The experimental results show the superiority of this calibration method compared with other calibration methods.
Using the calibration results of our method, in the measurement range of −45°∼ 45°, the rotation angle measurement error was less than ±0.
032°.
In the measurement range of 0 ∼ 39 mm, the displacement measurement error was less than ±0.
047 mm.
As for the length measurement of a 300 × 225 mm target, the length measurement error was less than ±0.
039 mm.
Related Results
COMPARISON OF BINOCULAR SPECTACLE PRESCRIPTION VERSUS PATCHING THERAPY IN REFRACTIVE AMBLYOPIA PATIENTS
COMPARISON OF BINOCULAR SPECTACLE PRESCRIPTION VERSUS PATCHING THERAPY IN REFRACTIVE AMBLYOPIA PATIENTS
Background: Amblyopia is the leading cause of visual impairment in children, adolescents, and middle-aged adults, characterized by a loss of binocularity and a significant reductio...
Frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students
Frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students
AIM: To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.
METHODS: Totally 158 st...
High-precision binocular camera calibration method based on a 3D calibration object
High-precision binocular camera calibration method based on a 3D calibration object
A high-precision binocular camera calibration method is proposed to address the issues of poor calibration accuracy and large calibration errors in current practical applications. ...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Retinitis Pigmentosa
Retinitis Pigmentosa
In studying the cases with typical and atypical pigmentary degeneration of the retina we strived to analyse in the clinical material all ophthalmoscopic and ocular changes together...
A binocular synaptic network supports interocular response alignment in visual cortical neurons
A binocular synaptic network supports interocular response alignment in visual cortical neurons
AbstractIn the visual system, signals from the two eyes are combined to form a coherent representation through the convergence of synaptic input populations onto individual cortica...
Ab initio Binocular Formulation of Listing's Law
Ab initio Binocular Formulation of Listing's Law
Abstract
Human eyes do not have perfectly aligned optical components; the fovea is displaced from the posterior pole, and the crystalline lens is tilted away from the optic...
Binocular processing facilitates escape behavior through multiple pathways to the superior colliculus
Binocular processing facilitates escape behavior through multiple pathways to the superior colliculus
SummaryThe superior colliculus (SC) is the main brain region regulating innate defensive behaviors to visual threat. Yet, how the SC integrates binocular visual information and to ...

