Radiofrequency Lesion Quality Markers: Current State of Knowledge

View through CrossRef
The long-term efficacy of radiofrequency catheter ablation is highly dependent on the location and size of the lesions delivered via the ablation catheter. This is particularly the case for radiofrequency ablation for atrial fibrillation, where contiguous, transmural lesions are required for durable pulmonary vein isolation. Therefore, reliable lesion quality markers that accurately relate to lesion size in the context of 3D mapping have been sought to improve the reliability of conduction block. Force–time integral, Ablation Index and Lesion Size Index are metrics currently used in clinical practice. Several studies have shown better clinical outcomes using these indices compared with using contact force alone or no marker at all. A theoretical limitation of these composite lesion indices is that they rely on input values such as contact force, application duration and power. A recent technology assessessing local tissue impedance (an output measure) has shown promising results. Temperature, another output measure, is not routinely used due to the significant impact of catheter irrigation on readings, but two recent catheter technologies have sought to overcome this obstacle. This paper provides an update on the current knowledge on these lesion quality markers.
Title: Radiofrequency Lesion Quality Markers: Current State of Knowledge
Description:
The long-term efficacy of radiofrequency catheter ablation is highly dependent on the location and size of the lesions delivered via the ablation catheter.
This is particularly the case for radiofrequency ablation for atrial fibrillation, where contiguous, transmural lesions are required for durable pulmonary vein isolation.
Therefore, reliable lesion quality markers that accurately relate to lesion size in the context of 3D mapping have been sought to improve the reliability of conduction block.
Force–time integral, Ablation Index and Lesion Size Index are metrics currently used in clinical practice.
Several studies have shown better clinical outcomes using these indices compared with using contact force alone or no marker at all.
A theoretical limitation of these composite lesion indices is that they rely on input values such as contact force, application duration and power.
A recent technology assessessing local tissue impedance (an output measure) has shown promising results.
Temperature, another output measure, is not routinely used due to the significant impact of catheter irrigation on readings, but two recent catheter technologies have sought to overcome this obstacle.
This paper provides an update on the current knowledge on these lesion quality markers.

Related Results

Eficacia, seguridad y eficiencia de la radioterapia corporal estereotáctica aplicada con marcadores de referencia en oncología
Eficacia, seguridad y eficiencia de la radioterapia corporal estereotáctica aplicada con marcadores de referencia en oncología
Introduction Stereotactic body radiotherapy (SBRT) is a technology that involves delivering high doses of radiation, in few sessios and with high precision, to a specific tumor loc...
Gastric Pyloric Schwannoma: A Case Report and Review of the Literature
Gastric Pyloric Schwannoma: A Case Report and Review of the Literature
Abstract Introduction Schwannomas are slow-growing, subclinical neoplasms rarely found in the gastrointestinal tract. This study reports a schwannoma in the pyloric region of the s...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Identification and characterization of Allium cepa potential intron polymorphism markers
Identification and characterization of Allium cepa potential intron polymorphism markers
Abstract Allium cepa is a widely grown crop for its spice and culinary properties. For molecular breeding of Allium cepa and its improvement, mining and utilization of vari...
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Primary Thyroid Non-Hodgkin B-Cell Lymphoma: A Case Series
Abstract Introduction Non-Hodgkin lymphoma (NHL) of the thyroid, a rare malignancy linked to autoimmune disorders, is poorly understood in terms of its pathogenesis and treatment o...
Endocardial Versus Epicardial Ventricular Radiofrequency Ablation
Endocardial Versus Epicardial Ventricular Radiofrequency Ablation
Background— Contact force (CF) is an important determinant of lesion formation for atrial endocardial radiofrequency ablation. There are minimal published data on CF an...
Therapeutic efficacy of radiofrequency ablation in hepatocellular carcinoma evaluated with MRI and serum alpha-fetoprotein
Therapeutic efficacy of radiofrequency ablation in hepatocellular carcinoma evaluated with MRI and serum alpha-fetoprotein
Objective: To investigate the feasibility of combined magnetic resonance imaging and serum alpha-fetoprotein for evaluating the therapeutic efficacy of radiofrequency ablation in p...

Back to Top