An evaluation of the NUI Compact Chest Compression Device (NCCD), a mechanical CPR device suitable for use in the saturation diving environment

View through CrossRef
Introduction: Provision of manual chest compressions in a diving bell using a conventional technique is often impossible, and alternative techniques are poorly evidenced in terms of efficacy and sustainability. The first mechanical cardiopulmonary resuscitation (CPR) device suitable for use in this environment, the NUI Compact Chest Compression Device (NCCD), has recently been designed and manufactured. This study assessed both the efficacy of the device in delivering chest compressions to both prone and seated manikins, and the ability of novice users to apply and operate it. Methods: Compression efficacy was assessed using a Resusi Anne QCPR intelligent manikin, and the primary outcome was the proportion of compressions delivered to target depth (50–60 mm). The gold standard was that achieved by expert CPR providers delivering manual CPR; the LUCAS 3 mCPR device was a further comparator. Results: The NCCD delivered 100% of compressions to target depth compared to 98% for the gold standard (interquartile range 1.5%) and 98% for the LUCAS 3 when applied to both supine and seated manikins. The NCCD sometimes became dislodged and had to be reapplied when used with a seated manikin. Conclusions: The NCCD can deliver chest compressions at target rate and depth to both supine and seated manikins with efficacy equivalent to manual CPR and the LUCAS 3. It can become dislodged when applied to a seated manikin; its design has now been altered to prevent this. New users can be trained in use of the NCCD quickly, but practise is required to ensure effective use.
Title: An evaluation of the NUI Compact Chest Compression Device (NCCD), a mechanical CPR device suitable for use in the saturation diving environment
Description:
Introduction: Provision of manual chest compressions in a diving bell using a conventional technique is often impossible, and alternative techniques are poorly evidenced in terms of efficacy and sustainability.
The first mechanical cardiopulmonary resuscitation (CPR) device suitable for use in this environment, the NUI Compact Chest Compression Device (NCCD), has recently been designed and manufactured.
This study assessed both the efficacy of the device in delivering chest compressions to both prone and seated manikins, and the ability of novice users to apply and operate it.
Methods: Compression efficacy was assessed using a Resusi Anne QCPR intelligent manikin, and the primary outcome was the proportion of compressions delivered to target depth (50–60 mm).
The gold standard was that achieved by expert CPR providers delivering manual CPR; the LUCAS 3 mCPR device was a further comparator.
Results: The NCCD delivered 100% of compressions to target depth compared to 98% for the gold standard (interquartile range 1.
5%) and 98% for the LUCAS 3 when applied to both supine and seated manikins.
The NCCD sometimes became dislodged and had to be reapplied when used with a seated manikin.
Conclusions: The NCCD can deliver chest compressions at target rate and depth to both supine and seated manikins with efficacy equivalent to manual CPR and the LUCAS 3.
It can become dislodged when applied to a seated manikin; its design has now been altered to prevent this.
New users can be trained in use of the NCCD quickly, but practise is required to ensure effective use.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
CONTINUOUS COMPRESSION WITHOUT DEFIBRILLATION FAVOURED NO SHORT-TERM SURVIVAL IN PROLONGED VENTRICULAR FIBRILLATION
CONTINUOUS COMPRESSION WITHOUT DEFIBRILLATION FAVOURED NO SHORT-TERM SURVIVAL IN PROLONGED VENTRICULAR FIBRILLATION
Objectives Aims: During the 2005 American Heart Association (AHA) Consensus Conference, compression first versus defibrillation first for sudden cardiac arrest wi...
Common Pool Resources
Common Pool Resources
Common pool resources (CPRs) are characterized as resources for which the exclusion of users is difficult (referred to as excludability), and the use of such a resource by one user...
Chest Wall Hydatid Cysts: A Systematic Review
Chest Wall Hydatid Cysts: A Systematic Review
Abstract Introduction Given the rarity of chest wall hydatid disease, information on this condition is primarily drawn from case reports. Hence, this study systematically reviews t...
ONE-SHOCK VERSUS CONTINUOUS DEFIBRILLATION IN AN 8-MIN VENTRICULAR FIBRILLATION CANINE MODEL OF CARDIAC ARREST
ONE-SHOCK VERSUS CONTINUOUS DEFIBRILLATION IN AN 8-MIN VENTRICULAR FIBRILLATION CANINE MODEL OF CARDIAC ARREST
Objectives To investigate the resuscitation effect of a one-shock defibrillation protocol versus conventional continuous defibrillation with treatment variation i...

Back to Top