SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
View through CrossRef
Background and Objective: The most common hand fractures among adult population are distal radius fractures and optimal management of these fractures remains controversial. Several surgical strategies are available to treat these fractures. Two most commonly used procedures volar locking plates and percutaneous K-wire fixation are used to treat distal radius fractures.The objective of this study was to compare outcome in distal radius fractures in volar locking plate and in K-wire fixation and in terms of functional and clinical outcome.
Methods: We conducted a randomized control trial at department of orthopedic surgery, Services Institute of Medical Sciences Lahore. After approval from the Ethical Review Board, a total number of 80 patients with distal radius fractures fulfilling the inclusion criteria were included. In Group A, distal radius fractures were fixed with volar locking plate and in Group B, K-wires were used to fix the distal radius fractures. Patients with polytrauma, head injury and spine injury were excluded from the study. Follow up was done at 2, 4, 6 weeks, 3 months and final at 6 months. Functional and clinical outcomes were measured with DASH Score and PREW Score at 3 months and 6 months.
Results:- Age range was 18-80 years, mean age was 61.3 + 14.5 years. Mechanism of injury was fall on outstretched hands in 45 (56.2%) patients, fall from height in 20 (25.0%) patients, motorbike accidents in 7 (8.8%) patients, injury after fight in 4 (5.0%) patients and 4 (5.0%) patients were having machine injury. No difference in radiological outcomes was recorded in the final follow up. There was no difference in volar tilt loss. It was 0.5o in plate group and 0.7o in K-wires group (p = 0.92). Radial length loss was 1mm in Group A and 1.2mm in Group B (p = 0.55). The loss of angle of radial inclination was 1.2o in Group A and 1.5o in Group B (p = 0.35) at the final follow up. There were 04 cases of superficial infection in Group B (10%) versus 01 in Group A (2.5%, p = 0.001).
Conclusion:- Our study shows that no mode of treatment in distal radius fractures is superior to other. The results of volar locking plate as compared to K-wire fixation were slightly better in the initial period but on long term bases both of these techniques have excellent and comparable results. DASH Score and PREW Score were almost equal in both of these techniques. The functional outcomes were almost equal in both of these techniques The complication rate although slightly more in K-wires group but it was insignificant from functional point of view.
Allama Iqbal Medical college, Lahore
Title: SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
Description:
Background and Objective: The most common hand fractures among adult population are distal radius fractures and optimal management of these fractures remains controversial.
Several surgical strategies are available to treat these fractures.
Two most commonly used procedures volar locking plates and percutaneous K-wire fixation are used to treat distal radius fractures.
The objective of this study was to compare outcome in distal radius fractures in volar locking plate and in K-wire fixation and in terms of functional and clinical outcome.
Methods: We conducted a randomized control trial at department of orthopedic surgery, Services Institute of Medical Sciences Lahore.
After approval from the Ethical Review Board, a total number of 80 patients with distal radius fractures fulfilling the inclusion criteria were included.
In Group A, distal radius fractures were fixed with volar locking plate and in Group B, K-wires were used to fix the distal radius fractures.
Patients with polytrauma, head injury and spine injury were excluded from the study.
Follow up was done at 2, 4, 6 weeks, 3 months and final at 6 months.
Functional and clinical outcomes were measured with DASH Score and PREW Score at 3 months and 6 months.
Results:- Age range was 18-80 years, mean age was 61.
3 + 14.
5 years.
Mechanism of injury was fall on outstretched hands in 45 (56.
2%) patients, fall from height in 20 (25.
0%) patients, motorbike accidents in 7 (8.
8%) patients, injury after fight in 4 (5.
0%) patients and 4 (5.
0%) patients were having machine injury.
No difference in radiological outcomes was recorded in the final follow up.
There was no difference in volar tilt loss.
It was 0.
5o in plate group and 0.
7o in K-wires group (p = 0.
92).
Radial length loss was 1mm in Group A and 1.
2mm in Group B (p = 0.
55).
The loss of angle of radial inclination was 1.
2o in Group A and 1.
5o in Group B (p = 0.
35) at the final follow up.
There were 04 cases of superficial infection in Group B (10%) versus 01 in Group A (2.
5%, p = 0.
001).
Conclusion:- Our study shows that no mode of treatment in distal radius fractures is superior to other.
The results of volar locking plate as compared to K-wire fixation were slightly better in the initial period but on long term bases both of these techniques have excellent and comparable results.
DASH Score and PREW Score were almost equal in both of these techniques.
The functional outcomes were almost equal in both of these techniques The complication rate although slightly more in K-wires group but it was insignificant from functional point of view.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Introduction: Distal radius fractures constitute one of the most prevalent upper extremity orthopedic injuries, predominantly resulting from falls onto an outstretched hand with an...
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
Functional Outcome and Range of Motion Between Internal Plate Fixation Versus Kirschner Wire for Management of Distal Radius Fracture: A Meta-Analysis
Functional Outcome and Range of Motion Between Internal Plate Fixation Versus Kirschner Wire for Management of Distal Radius Fracture: A Meta-Analysis
Introduction: A significant percentage of fractures treated in clinical practice are distal radius fractures, which are among the most common orthopaedics injuries. Distal radius f...
PANORAMIC REVIEW OF DISTAL RADIUS FRACTURES
PANORAMIC REVIEW OF DISTAL RADIUS FRACTURES
Introduction: fractures affecting the distal radius are common, their incidence increases as life expectancy increases, leading to a larger population of individuals at risk of suf...
Incidence of Anti-osteoporosis Diagnosis and Treatment After Distal Radius Fractures
Incidence of Anti-osteoporosis Diagnosis and Treatment After Distal Radius Fractures
Introduction: There is still lack of adequate diagnosis and treatment of osteoporosis in elderly patients. Hand surgeons can prevent secondary osteoporotic fractures when treating ...
Outcome of Volar Plate in Patients with Intra Articular Distal Radius Fracture
Outcome of Volar Plate in Patients with Intra Articular Distal Radius Fracture
Background: Intra-articular variations of distal radius fractures, which are common orthopedic injuries, might make it difficult to achieve anatomical reduction and functional reha...
Comparative analysis of external locking plate and combined frame external fixator for open distal tibial fractures: a comprehensive assessment of clinical outcomes and financial implications
Comparative analysis of external locking plate and combined frame external fixator for open distal tibial fractures: a comprehensive assessment of clinical outcomes and financial implications
Abstract
Background
Open distal tibial fractures pose significant challenges regarding treatment options and patient outcomes. This retrospective si...