The scissors sign: a provocative test for detecting the leading-edge tear of subscapularis tendon: a diagnostic study

View through CrossRef
Abstract Background Several physical examination tests and signs have been described to aid in the diagnosis of subscapularis (SSC) tear, but have limitations and variable sensitivity. This study aimed to introduce a novel test for detecting a leading-edge tear of the subscapularis (LETS), the most important tendinous portion of SSC. Methods A total of 233 patients who underwent arthroscopic repair for anterior and superior cuff tears between January 2018 to September 2019 were retrospectively reviewed. The provocative test we have coined as the “scissors sign” and the other related clinical tests (i.e., belly press, belly off, Napoleon, lift off, internal rotation lag, bear hug tests) were performed preoperatively. Whether the patient has a LETS or the complete tear of the SSC (CTS) was confirmed by arthroscopic findings. Sensitivity, specificity, and areas under the receiver operating characteristic curve were calculated for each test. Results In patients who had LETS with or without supraspinatus tear, the scissors sign showed the highest sensitivity (91.4%) with a specificity of 81.6%, positive predictive value (PPV) of 80.2%, and negative predictive value (NPV) of 92.1%. In patients with isolated LETS, the scissors sign also showed the highest sensitivity (90.3%) with a specificity of 81.6%, PPV of 57.1%, and NPV of 96.8%. The scissors sign for the complete tear of the subscapularis (CTS) with or without supraspinatus tear and the isolated CTS had a sensitivity of 73.1 and 75%, respectively. Conclusions The scissors sign is a novel provocative test that can be helpful in the diagnosis of subscapularis tears, especially LETS, with its high sensitivity and diagnostic accuracy. In combination with other tests, the scissors sign will be a good screening tool.
Title: The scissors sign: a provocative test for detecting the leading-edge tear of subscapularis tendon: a diagnostic study
Description:
Abstract Background Several physical examination tests and signs have been described to aid in the diagnosis of subscapularis (SSC) tear, but have limitations and variable sensitivity.
This study aimed to introduce a novel test for detecting a leading-edge tear of the subscapularis (LETS), the most important tendinous portion of SSC.
Methods A total of 233 patients who underwent arthroscopic repair for anterior and superior cuff tears between January 2018 to September 2019 were retrospectively reviewed.
The provocative test we have coined as the “scissors sign” and the other related clinical tests (i.
e.
, belly press, belly off, Napoleon, lift off, internal rotation lag, bear hug tests) were performed preoperatively.
Whether the patient has a LETS or the complete tear of the SSC (CTS) was confirmed by arthroscopic findings.
Sensitivity, specificity, and areas under the receiver operating characteristic curve were calculated for each test.
Results In patients who had LETS with or without supraspinatus tear, the scissors sign showed the highest sensitivity (91.
4%) with a specificity of 81.
6%, positive predictive value (PPV) of 80.
2%, and negative predictive value (NPV) of 92.
1%.
In patients with isolated LETS, the scissors sign also showed the highest sensitivity (90.
3%) with a specificity of 81.
6%, PPV of 57.
1%, and NPV of 96.
8%.
The scissors sign for the complete tear of the subscapularis (CTS) with or without supraspinatus tear and the isolated CTS had a sensitivity of 73.
1 and 75%, respectively.
Conclusions The scissors sign is a novel provocative test that can be helpful in the diagnosis of subscapularis tears, especially LETS, with its high sensitivity and diagnostic accuracy.
In combination with other tests, the scissors sign will be a good screening tool.

Related Results

Prevalensi Absensi Palmaris Longus Tendon Suku Lampung Pada Civitas Akademika Universitas Malahayati Bandar Lampung
Prevalensi Absensi Palmaris Longus Tendon Suku Lampung Pada Civitas Akademika Universitas Malahayati Bandar Lampung
ABSTRAK Latar Belakang : Perkembangan tendon Palmaris Longus sudah lengkap saat dilahirkan. Tendon Palmaris Longus tidak akan berkembang lagi sesudah itu. tendon Palmaris Longus se...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
RUPTURED ACHILLES TENDON, A COMMON INJURY IN ATHLETES
RUPTURED ACHILLES TENDON, A COMMON INJURY IN ATHLETES
Introduction: The Achilles tendon also named calcaneal tendon, can be subjected to tensile loads up to 10 times the body weight. It is located on the posterior aspect of the lower ...
Spontaneous Bilateral Patellar Tendon Rupture in Patient with Ehlers–Danlos Syndrome: A Case Report
Spontaneous Bilateral Patellar Tendon Rupture in Patient with Ehlers–Danlos Syndrome: A Case Report
Introduction: Bilateral spontaneous patellar tendon ruptures are rare, though it is hypothesized to be more common in patients with risk factors such as connective tissue disorders...
Association of Supraspinatus Tear Type and Localisation Between Humeral Head Bone Cyst
Association of Supraspinatus Tear Type and Localisation Between Humeral Head Bone Cyst
Objective: This study aims to comprehensively explore the association between different types and locations of supraspinatus tendon tears and the presence of humeral head bone cyst...
High-Performance Tendon For TLP Manufactured By Quench And Temper
High-Performance Tendon For TLP Manufactured By Quench And Temper
Abstract For the purpose of cost saving, three-piece tendon, which consists of a straight pipe with a couple of threaded forging connectors welded to both ends, i...
Biomimetic Breakthrough: Enhancing Tendon Repair with dAM- TDSCs
Biomimetic Breakthrough: Enhancing Tendon Repair with dAM- TDSCs
Abstract Background Adhesions and poor healing are major complications after Achilles tendon injury, and there is no effective solution to this problem. The purpose of this...

Back to Top