Javascript must be enabled to continue!
Research on Blood Pressure Monitoring Based on Flexible Encapsulated Sensors
View through CrossRef
In order to realize the accurate measurement of wearable sphygmomanometer, this paper selects the micro electro mechanical system (MEMS) pressure sensor with small size, low cost and high accuracy, and proposes a flexible packaging method combining Parylene and Polydimethylsiloxane (PDMS). The flexible packaging sensor protects the sensor chip while ensuring the comfort of the measured person. It can be worn for a long time, and the encapsulated sensor has good accuracy and sensitivity. At the same time, the encapsulated MEMS pressure sensor was used to collect good pulse signals and extract multiple pulse wave characteristic parameters. A blood pressure measurement method based on the combination of arterial tonometry method and pulse wave parameters method was proposed, and multiple machine learning algorithms were compared and analyzed to select the algorithm model with the smallest error as the optimal regressor. The experimental results show that the blood pressure measurement method combining the arterial tonometry method and the pulse wave parameters method can effectively improve the accuracy of blood pressure measurement. The experimental results demonstrate that the combination of arterial tonometry and pulse wave parameter methods can effectively enhance the accuracy of blood pressure measurement, with the random forest model serving as the optimal regressor. The average deviation between the systolic blood pressure measured by our self-made sphygmomanometer and the commercial sphygmomanometer was 0.86mmHg, with a standard deviation of 4.04mmHg. The average deviation of diastolic blood pressure was 0.63mmHg, with a standard deviation of 5.15mmHg, meeting the AAMI standard for clinical practice.
Title: Research on Blood Pressure Monitoring Based on Flexible Encapsulated Sensors
Description:
In order to realize the accurate measurement of wearable sphygmomanometer, this paper selects the micro electro mechanical system (MEMS) pressure sensor with small size, low cost and high accuracy, and proposes a flexible packaging method combining Parylene and Polydimethylsiloxane (PDMS).
The flexible packaging sensor protects the sensor chip while ensuring the comfort of the measured person.
It can be worn for a long time, and the encapsulated sensor has good accuracy and sensitivity.
At the same time, the encapsulated MEMS pressure sensor was used to collect good pulse signals and extract multiple pulse wave characteristic parameters.
A blood pressure measurement method based on the combination of arterial tonometry method and pulse wave parameters method was proposed, and multiple machine learning algorithms were compared and analyzed to select the algorithm model with the smallest error as the optimal regressor.
The experimental results show that the blood pressure measurement method combining the arterial tonometry method and the pulse wave parameters method can effectively improve the accuracy of blood pressure measurement.
The experimental results demonstrate that the combination of arterial tonometry and pulse wave parameter methods can effectively enhance the accuracy of blood pressure measurement, with the random forest model serving as the optimal regressor.
The average deviation between the systolic blood pressure measured by our self-made sphygmomanometer and the commercial sphygmomanometer was 0.
86mmHg, with a standard deviation of 4.
04mmHg.
The average deviation of diastolic blood pressure was 0.
63mmHg, with a standard deviation of 5.
15mmHg, meeting the AAMI standard for clinical practice.
Related Results
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
Implementing a Self-measured Blood Pressure Monitoring Process
Implementing a Self-measured Blood Pressure Monitoring Process
Practice Problem: Because of the prevalence of hypertension worldwide, it is prudent for all patients to have the knowledge and ability to self-monitor their blood pressure. Patien...
All-Fabric Piezoionic Sensor for Simultaneous Sensing of Static and Dynamic Pressures
All-Fabric Piezoionic Sensor for Simultaneous Sensing of Static and Dynamic Pressures
The development of flexible and textile-based wearable pressure sensors has provided the opportunity of continuous and real time measurement of human physiological and biomechanica...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
AbstractIntroductionIn patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protective of future ischemic cerebral events. Reserve cerebral ...
Cross-Sectional Study on Knowledge, Attitude and Practice of Voluntary Blood Donation among Nursing Staff at Orotta National Referral Teaching Hospital Asmara, Eritrea
Cross-Sectional Study on Knowledge, Attitude and Practice of Voluntary Blood Donation among Nursing Staff at Orotta National Referral Teaching Hospital Asmara, Eritrea
Introduction: Blood transfusion is one of the essential components of quality health care service package. Safe blood for transfusion is obtained mainly from Voluntary blood donors...
Toxicity and anthelmintic efficacy of chitosan encapsulated bromelain against gastrointestinal strongyles in Small East African goats in Kenya
Toxicity and anthelmintic efficacy of chitosan encapsulated bromelain against gastrointestinal strongyles in Small East African goats in Kenya
Background and Aim: The development of resistance to anthelmintic drugs has prompted research into alternative methods of controlling intestinal nematodes in ruminants. This study ...
Pharmacogenomics and the Concept of Personalized Medicine for the Management of Hypertension
Pharmacogenomics and the Concept of Personalized Medicine for the Management of Hypertension
Hypertension poses a significant global burden due to low adherence to antihypertensive medications. Hypertension treatment aims to bring blood pressure within physiological ranges...

