Javascript must be enabled to continue!
The Viscoelastic Behavior of Soft Tissues Must be Accounted for in Stapler Design and Surgeon Technique
View through CrossRef
Background: Since its adoption as a surgical technique over a half-century ago, stapling has continually undergone improvements, both in the devices used and in our understanding of tissue mechanics. To best design and use stapling devices, it is beneficial to have an intimate knowledge of the response of tissue to compression and stapling dynamics. This paper provides the relevant background in the field of biomechanics, and in particular addresses the viscoelastic behavior of soft tissues under compression. Biomechanics of Stapling: The change in shape of a solid, or strain, is related to the load applied, or stress. Biological tissues are known to have non-linear relationships between stress and strain, and generally the relationships are anisotropic (dependent upon direction). Further complicating matters, there is typically a time-dependency to the relationship for compression and recovery, resulting in viscoelastic behavior. Hence both the amount and rate of compressive force applied can be expected to impact the outcome of stapling. Discussion: The growth of the laparoscopic use of staples has increased the difficulty of device design, as precise control of compression is problematic in extended length staplers. Progressive firing along the cartridge and multi-stage compression have both been found to be beneficial in providing the uniform force needed to produce well-formed staples. Such technical advances can reduce stresses within the stapler, preventing deformation of the stapler arm and undesirable strain in the tissue. Current research includes understanding the effects of changing the rate of compression on staple formation with the hope that further improvements can be achieved in this ever-fruitful method of tissue apposition.
Surgical Technology Online
Title: The Viscoelastic Behavior of Soft Tissues Must be Accounted for in Stapler Design and Surgeon Technique
Description:
Background: Since its adoption as a surgical technique over a half-century ago, stapling has continually undergone improvements, both in the devices used and in our understanding of tissue mechanics.
To best design and use stapling devices, it is beneficial to have an intimate knowledge of the response of tissue to compression and stapling dynamics.
This paper provides the relevant background in the field of biomechanics, and in particular addresses the viscoelastic behavior of soft tissues under compression.
Biomechanics of Stapling: The change in shape of a solid, or strain, is related to the load applied, or stress.
Biological tissues are known to have non-linear relationships between stress and strain, and generally the relationships are anisotropic (dependent upon direction).
Further complicating matters, there is typically a time-dependency to the relationship for compression and recovery, resulting in viscoelastic behavior.
Hence both the amount and rate of compressive force applied can be expected to impact the outcome of stapling.
Discussion: The growth of the laparoscopic use of staples has increased the difficulty of device design, as precise control of compression is problematic in extended length staplers.
Progressive firing along the cartridge and multi-stage compression have both been found to be beneficial in providing the uniform force needed to produce well-formed staples.
Such technical advances can reduce stresses within the stapler, preventing deformation of the stapler arm and undesirable strain in the tissue.
Current research includes understanding the effects of changing the rate of compression on staple formation with the hope that further improvements can be achieved in this ever-fruitful method of tissue apposition.
Related Results
The peridynamic model of viscoelastic creep and recovery
The peridynamic model of viscoelastic creep and recovery
Purpose
– The purpose of this paper is to establish a peridynamic method in predicting viscoelastic creep behaviour with recovery stage and to find the suitable num...
Redesign of Electrical Stapler Design: An Approach to Reduce Muscle Fatigue of Surgeons
Redesign of Electrical Stapler Design: An Approach to Reduce Muscle Fatigue of Surgeons
Muscle fatigue caused by using staplers affects the surgical procedures of surgeons. Compared to manual staplers, electric staplers decrease the muscle fatigue by replacing repeate...
Soft Power with Chinese Specifics: Concept and Approaches
Soft Power with Chinese Specifics: Concept and Approaches
The purpose of the study. Joseph Nye’s theory of soft power has enriched the idea of the country’s comprehensive power and attracted great attention from the Chinese theoretical co...
SIFAT-SIFAT MODUL SOFT
SIFAT-SIFAT MODUL SOFT
Suatu himpunan tak kosong disebut modul atas suatu ring dengan elemen satuan jika himpunan tersebut merupakan grup komutatif yang tertutup terhadap perkalian skalar yang memenuhi b...
MINIMALLY INVASIVE APPROACH UTILIZING LINEAR STAPLER FOR MIDLINE INCISIONAL HERNIA: STAPLER REPAIR TECHNIQUE
MINIMALLY INVASIVE APPROACH UTILIZING LINEAR STAPLER FOR MIDLINE INCISIONAL HERNIA: STAPLER REPAIR TECHNIQUE
Abstract
Background
We have successfully developed the Stapler Repair Technique (SRT), a straightforward laparoscopic Rives-Stop...
Comparative Study of Tensile Strength in Vicryl™ vs. Prolene™ 5-0 Knots: Impact of Throw Type and Count
Comparative Study of Tensile Strength in Vicryl™ vs. Prolene™ 5-0 Knots: Impact of Throw Type and Count
Abstract
Background
Knots are the weakest point of sutures, making their security and tensile strength critical. While suture ma...
Passive damping of the beam elements of antenna systems
Passive damping of the beam elements of antenna systems
Beams are one of the most common elements of antennas - they can be used both as elements for receiving and transmitting radio signals, and as design solutions for various purposes...