Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

FEATURES OF FIRE PROTECTION TREATMENT OF LOAD-BEARING BUILDING STRUCTURES

View through CrossRef
The article emphasizes that wood is a flammable material, flames spread quickly, which poses a threat to building structures. Therefore, it must be protected by effective means of fire protection. Regulatory and technical documentation is presented, which establishes requirements for the quality of fire protection of wooden structures. Using the example of state reserve enterprises, it is shown that there are many methods of fire-resistant treatment of wooden structures with flame retardants. Among them are the impregnation of wood with inorganic salts and the application of coatings on an organic basis. These include impregnation of wood with inorganic salts and application of coatings on an organic basis. It is shown that the specified methods of processing have disadvantages during application and operation, which include the moistening of wood under the influence of external natural factors, which leads to the dissolution and leaching of salts, increased smoke formation, and the formation of toxic combustion products. The constituent parts of the intumescent coating are proposed and their effectiveness in relation to fire protection of wood is determined. Depending on the content of PVA-dispersion, a change in the coefficient of swelling was determined, which is in the range from 14.3 to 25.1. Thus, it was determined that when mineral fillers are added to the composition of the organo-mineral composition in the amount of 10%, it helps to increase the coefficient of swelling from 30 to 36.7, which is 1.5...1.84 times greater than the value of the coefficient of swelling of the optimal composition of the organo-mineral composition without fillers. The article presents research on the creation of fire-resistant intumescent coatings capable of providing a wide range of fire-resistant and operational properties. After testing samples treated with an intumescent coating, under the action of a burner flame, a sample weight loss of no more than 6% was obtained, and the temperature of flue gases did not exceed 184ºС, which refers the treated wood to the group of non-combustible materials. Thus, the intumescent coating provides the first group of fire protection efficiency. Keywords: building structures, fire-resistant treatment, state reserve enterprises, intumescent coatings, fire-resistant properties, efficiency.
Title: FEATURES OF FIRE PROTECTION TREATMENT OF LOAD-BEARING BUILDING STRUCTURES
Description:
The article emphasizes that wood is a flammable material, flames spread quickly, which poses a threat to building structures.
Therefore, it must be protected by effective means of fire protection.
Regulatory and technical documentation is presented, which establishes requirements for the quality of fire protection of wooden structures.
Using the example of state reserve enterprises, it is shown that there are many methods of fire-resistant treatment of wooden structures with flame retardants.
Among them are the impregnation of wood with inorganic salts and the application of coatings on an organic basis.
These include impregnation of wood with inorganic salts and application of coatings on an organic basis.
It is shown that the specified methods of processing have disadvantages during application and operation, which include the moistening of wood under the influence of external natural factors, which leads to the dissolution and leaching of salts, increased smoke formation, and the formation of toxic combustion products.
The constituent parts of the intumescent coating are proposed and their effectiveness in relation to fire protection of wood is determined.
Depending on the content of PVA-dispersion, a change in the coefficient of swelling was determined, which is in the range from 14.
3 to 25.
1.
Thus, it was determined that when mineral fillers are added to the composition of the organo-mineral composition in the amount of 10%, it helps to increase the coefficient of swelling from 30 to 36.
7, which is 1.
5.
1.
84 times greater than the value of the coefficient of swelling of the optimal composition of the organo-mineral composition without fillers.
The article presents research on the creation of fire-resistant intumescent coatings capable of providing a wide range of fire-resistant and operational properties.
After testing samples treated with an intumescent coating, under the action of a burner flame, a sample weight loss of no more than 6% was obtained, and the temperature of flue gases did not exceed 184ºС, which refers the treated wood to the group of non-combustible materials.
Thus, the intumescent coating provides the first group of fire protection efficiency.
Keywords: building structures, fire-resistant treatment, state reserve enterprises, intumescent coatings, fire-resistant properties, efficiency.

Related Results

Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...
Research on Rolling-Sliding Integrated Auxiliary Bearing and its Application in High Temperature Reactor
Research on Rolling-Sliding Integrated Auxiliary Bearing and its Application in High Temperature Reactor
The active magnetic bearings (AMB), with the advantages of no friction, no abrasion, no lubrication and active control, is used in the primary helium circulator for high-temperatur...
Cost Comparison between RCC and Load Bearing Earthquake Resistant Residential Building in Terai Region
Cost Comparison between RCC and Load Bearing Earthquake Resistant Residential Building in Terai Region
This study compares the cost-effectiveness of earthquake-resistant residential construction methods, focusing on RCC framed structures and load-bearing construction in Kanchan Rura...
Der skal ikke lades sten på sten tilbage
Der skal ikke lades sten på sten tilbage
The Building by the Barbar TempleClose by the large temple at Barbar 1) lies a little tell, which was investigated in the spring of 1956. The tell was shown to cover a building of ...
Recent Patents on Detection of Bearing Temperature
Recent Patents on Detection of Bearing Temperature
Background: One of the critical factors affecting the life of bearings is the bearing temperature during operation, so the temperature is an important parameter to detect the runni...
Study on Multiscale Hydrodynamic Step Bearing
Study on Multiscale Hydrodynamic Step Bearing
In a step bearing, when the surface separation is so low that it is comparable with the thickness of the physical adsorbed layer on the bearing surface, the physical adsorbed layer...
Uniaxial Compression Response and Instability Mechanisms of Parallel Dual Coal Pillar–Roof Combinations
Uniaxial Compression Response and Instability Mechanisms of Parallel Dual Coal Pillar–Roof Combinations
The remaining coal pillars and roof form an integral coal pillar–roof system (CPRS) that plays an important role in the safety of the room mining goaf. In this research, two differ...
CFD analysis of load-carrying capacity of hydrodynamic lubrication on a water-lubricated journal bearing
CFD analysis of load-carrying capacity of hydrodynamic lubrication on a water-lubricated journal bearing
Purpose– The purpose of this paper is to improve hydrodynamic load-carrying capacity of a water-lubricated journal bearing by a new bush structure. Water-lubricated bearing is beco...

Back to Top