Javascript must be enabled to continue!
Results of Autopsy 7 Months after Successful Endoluminal Treatment of an Infrarenal Abdominal Aortic Aneurysm
View through CrossRef
Purpose:To report the results of a postmortem examination in a patient who died of unrelated causes 7 months following endoluminal treatment of an infrarenal abdominal aortic aneurysm (AAA).Methods:As part of an FDA Phase I pilot study, a 73-year-old man underwent successful endoluminal exclusion of an infrarenal AAA using a 9-cm-long endograft (Endovascular Grafting System). Seven months later, he succumbed to complications of a spontaneous esophageal rupture. At autopsy, the aorta was dissected in situ by a vascular surgeon and pathologist before being explanted in order to examine the wound healing characteristics at the aorta-endograft interface. Particular attention was also directed to the hooks composing the attachment system at each end of the endograft.Results:Macroscopic and microscopic examination revealed that the graft had completely excluded the aneurysm sac from the circulation and was incorporated into the aortic wall at the proximal neck and distal cuff. A smooth pannus of endothelial cells covered the proximal end of the endograft at the areas of contact with the aorta, while microscopic examination of the distal end of the graft revealed poorly formed, fibrinous pannus. The neointima deep to the endothelium consisted of a collagenous matrix containing myofibroblasts and histiocytes, providing evidence of healing between the endograft and aorta. Both renal arteries were clear of the proximal end of the endograft, but a previously unrecognized right lower pole renal artery with an extremely caudal origin was excluded from the aortic lumen. Each hook of the attachment system was seen protruding through the adventitia of the aorta. There was no evidence of trauma to the aortic wall or the surrounding tissues caused by these hooks.Conclusion:There appears to be evidence that an endoluminally placed aortic graft may be incorporated by the host aortic tissue.
Title: Results of Autopsy 7 Months after Successful Endoluminal Treatment of an Infrarenal Abdominal Aortic Aneurysm
Description:
Purpose:To report the results of a postmortem examination in a patient who died of unrelated causes 7 months following endoluminal treatment of an infrarenal abdominal aortic aneurysm (AAA).
Methods:As part of an FDA Phase I pilot study, a 73-year-old man underwent successful endoluminal exclusion of an infrarenal AAA using a 9-cm-long endograft (Endovascular Grafting System).
Seven months later, he succumbed to complications of a spontaneous esophageal rupture.
At autopsy, the aorta was dissected in situ by a vascular surgeon and pathologist before being explanted in order to examine the wound healing characteristics at the aorta-endograft interface.
Particular attention was also directed to the hooks composing the attachment system at each end of the endograft.
Results:Macroscopic and microscopic examination revealed that the graft had completely excluded the aneurysm sac from the circulation and was incorporated into the aortic wall at the proximal neck and distal cuff.
A smooth pannus of endothelial cells covered the proximal end of the endograft at the areas of contact with the aorta, while microscopic examination of the distal end of the graft revealed poorly formed, fibrinous pannus.
The neointima deep to the endothelium consisted of a collagenous matrix containing myofibroblasts and histiocytes, providing evidence of healing between the endograft and aorta.
Both renal arteries were clear of the proximal end of the endograft, but a previously unrecognized right lower pole renal artery with an extremely caudal origin was excluded from the aortic lumen.
Each hook of the attachment system was seen protruding through the adventitia of the aorta.
There was no evidence of trauma to the aortic wall or the surrounding tissues caused by these hooks.
Conclusion:There appears to be evidence that an endoluminally placed aortic graft may be incorporated by the host aortic tissue.
Related Results
Imaging Characteristic of Abdominal Aortic Aneurysm on CTscanner at E Hospital
Imaging Characteristic of Abdominal Aortic Aneurysm on CTscanner at E Hospital
Abstract: Abdominal aortic aneurysm is a swelling (aneurysm) of the aorta. Abdominal aortic aneurysms often grow slowly without noticeable symptoms, so screening by clinical examin...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Diseases of the Aorta
Diseases of the Aorta
This review covers the major presentations affecting the aorta: aortic aneurysms (abdominal aortic aneurysms and thoracic aortic aneurysms), acute aortic syndromes (including aorti...
Tobacco smoking and the risk of aortic aneurysm in the UK biobank
Tobacco smoking and the risk of aortic aneurysm in the UK biobank
Abstract
Smoking is an established risk factor for aortic aneurysm, however, few studies have investigated the associations with different aortic aneurysm subsites. The a...
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Background: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal functi...
Endovascular infrarenal abdominal aortic aneurysm repair
Endovascular infrarenal abdominal aortic aneurysm repair
Abdominal aortic aneurysm repair has undergone a revolution since Volodos and Parodi described endoluminal repair in the early 1990s. Subsequent data from large registries have con...
Role of computed tomography angiography for the diagnosis of cerebral aneurysm in patients with atherosclerosis.
Role of computed tomography angiography for the diagnosis of cerebral aneurysm in patients with atherosclerosis.
Objective: To determine the role of CT Angiography for the Diagnosis of Cerebral Aneurysm types in Patients with Atherosclerosis. Study Design: Retrospective study. Setting: Chught...
Inhibition of Aneurysm Progression by Direct Renin Inhibition in a Rabbit Model
Inhibition of Aneurysm Progression by Direct Renin Inhibition in a Rabbit Model
Angiotensin II is thought to participate in aneurysm formation, because of its ability to induce and perpetuate inflammation in the aortic wall. Because activation of renin is the ...

