Time-efficient relaxation measurements by 31P MR fingerprinting in human brain at 7T
View through CrossRef
AbstractPurposeThe goal of the study is to develop 31P spectroscopic MRF at 7T to measure T1 and T2 relaxation times simultaneously and to compare time efficiency and test-retest reproducibility of MRF with conventional inversion recovery and multi-TE methods.MethodsA 31P MRF scheme was designed based on a balanced steady-state free precession type sequence. Dictionary was generated using the Bloch equations. B0 map was acquired experimentally and incorporated into the dictionary. 7 phantoms with different T1 and T2 relaxation times were prepared for MRF validation. Simulations were performed to evaluate estimation bias. 7 volunteers were scanned twice using both MRF and the conventional methods to evaluate the reproducibility.ResultsIn phantom measurements, T1 and T2 values between MRF and conventional methods demonstrated a good agreement with Pearson’s correlation coefficients of 0.99 and 0.97, respectively. In in vivo experiments, estimated T1 by MRF were in good agreement with those measured by the inversion recovery and in the literature. On the other hand, estimated T2 values by MRF were shorter than those measured by the multi-TE method. 31P MRF method can reduce the acquisition time by 15 min providing less than 10% of mean CV for T1 estimations and less than 20% of mean CV for T2 estimations of metabolites.ConclusionOur results shows the feasibility of simultaneous T1 and T2 measurement of 31P metabolites in human brain using MRF at 7T. High reproducibility can be achieved especially for T1 measurement with 40% time reduction over conventional methods.
Cold Spring Harbor Laboratory
Title: Time-efficient relaxation measurements by 31P MR fingerprinting in human brain at 7T
Description:
AbstractPurposeThe goal of the study is to develop 31P spectroscopic MRF at 7T to measure T1 and T2 relaxation times simultaneously and to compare time efficiency and test-retest reproducibility of MRF with conventional inversion recovery and multi-TE methods.
MethodsA 31P MRF scheme was designed based on a balanced steady-state free precession type sequence.
Dictionary was generated using the Bloch equations.
B0 map was acquired experimentally and incorporated into the dictionary.
7 phantoms with different T1 and T2 relaxation times were prepared for MRF validation.
Simulations were performed to evaluate estimation bias.
7 volunteers were scanned twice using both MRF and the conventional methods to evaluate the reproducibility.
ResultsIn phantom measurements, T1 and T2 values between MRF and conventional methods demonstrated a good agreement with Pearson’s correlation coefficients of 0.
99 and 0.
97, respectively.
In in vivo experiments, estimated T1 by MRF were in good agreement with those measured by the inversion recovery and in the literature.
On the other hand, estimated T2 values by MRF were shorter than those measured by the multi-TE method.
31P MRF method can reduce the acquisition time by 15 min providing less than 10% of mean CV for T1 estimations and less than 20% of mean CV for T2 estimations of metabolites.
ConclusionOur results shows the feasibility of simultaneous T1 and T2 measurement of 31P metabolites in human brain using MRF at 7T.
High reproducibility can be achieved especially for T1 measurement with 40% time reduction over conventional methods.
Related Results
Brain Organoids, the Path Forward?
Brain Organoids, the Path Forward?
Photo by Maxim Berg on Unsplash
INTRODUCTION
The brain is one of the most foundational parts of being human, and we are still learning about what makes humans unique. Advancements ...
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED]➢Item Name - Gro-X Brain➢ Creation - Natural Organic Compound➢ Incidental Effects - NA➢ Accessibility - Online➢ Rating - ⭐⭐⭐⭐⭐➢ Click Here To Visit - Official Website - ...
ATP, the 31P Spectral Modulus, and Metabolism
ATP, the 31P Spectral Modulus, and Metabolism
Adenosine triphosphate (ATP) has a high intracellular millimolar concentration (ca. 2.4 mM) throughout the phylogenetic spectrum of eukaryotes, archaea, and prokaryotes. In additio...
Reservoir Architecture and Fluid Connectivity in an Abu Dhabi Oil Accumulation
Reservoir Architecture and Fluid Connectivity in an Abu Dhabi Oil Accumulation
Summary
Developing an understanding of reservoir architecture and fluid connectivity is a challenging, but essential task for well, reservoir and facilities manageme...
A Study of Filtering Method for Accurate Indoor Positioning System Using Bluetooth Low Energy Beacons
A Study of Filtering Method for Accurate Indoor Positioning System Using Bluetooth Low Energy Beacons
Fingerprinting technique is an essential element in the indoor positioning system (IPS). Common methods utilize Wi-Fi signals. However, most of the Wi-Fi, because it is pre-install...
FP-tracer: Fine-grained Browser Fingerprinting Detection via Taint-tracking and Entropy-based Thresholds
FP-tracer: Fine-grained Browser Fingerprinting Detection via Taint-tracking and Entropy-based Thresholds
Browser fingerprinting is an effective technique to track web users by building a fingerprint from their browser attributes. It is also stealthy because the tracker uses legitimate...
Threads of time
Threads of time
This thesis advances the fundamental understanding of dilute polymer solution rheology through systematic investigation of extensional flow behavior, with particular focus on polye...
Comprehensive analysis of relaxation decays from high-resolution relaxometry
Comprehensive analysis of relaxation decays from high-resolution relaxometry
Relaxometry consists in measuring relaxation rates over orders of magnitude of magnetic fields to probe motions of complex systems. High-resolution relaxometry (HRR) experiments ca...