Javascript must be enabled to continue!
Metaphyseal cones in revision total knee arthroplasty
View through CrossRef
AimsMetaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.MethodsThis computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.ResultsSmall micromotions (mean < 12 µm) were found to occur at the bone-implant interface for all loading cases with or without a stem. Stem inclusion was associated with lower micromotion, however these reductions were too small to have any clinical significance. Peak interface micromotion, even when the cone is used without a stem, was too small to effect osseointegration. The maximum difference occurred with stair descent loading. Stress concentrations in the bone occurred around the inferior aspect of each implant, with the largest occurring at the end of the long stem; these may lead to end-of-stem pain. Stem use is also found to result in stress shielding in the bone along the stem.ConclusionWhen a metaphyseal cone is used at rTKA to manage uncontained posterior or medial defects of up to 10 mm depth, stem use may not be necessary. Cite this article: Bone Joint Res. 2020;9(4):162–172.
British Editorial Society of Bone & Joint Surgery
Title: Metaphyseal cones in revision total knee arthroplasty
Description:
AimsMetaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA).
Tibial stems provide additional fixation and are generally used in combination with cones.
The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.
MethodsThis computational study investigates whether stems are required to augment metaphyseal cones at rTKA.
Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.
ResultsSmall micromotions (mean < 12 µm) were found to occur at the bone-implant interface for all loading cases with or without a stem.
Stem inclusion was associated with lower micromotion, however these reductions were too small to have any clinical significance.
Peak interface micromotion, even when the cone is used without a stem, was too small to effect osseointegration.
The maximum difference occurred with stair descent loading.
Stress concentrations in the bone occurred around the inferior aspect of each implant, with the largest occurring at the end of the long stem; these may lead to end-of-stem pain.
Stem use is also found to result in stress shielding in the bone along the stem.
ConclusionWhen a metaphyseal cone is used at rTKA to manage uncontained posterior or medial defects of up to 10 mm depth, stem use may not be necessary.
Cite this article: Bone Joint Res.
2020;9(4):162–172.
Related Results
Midterm Outcomes of Posterior Cruciate Ligament Substituting Total Knee Arthroplasty
Midterm Outcomes of Posterior Cruciate Ligament Substituting Total Knee Arthroplasty
Objective: In the present study, it is aimed to retrospectively investigate and present the midterm results of the cases with posterior cruciate ligament (PCL) substituting total k...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract
Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Background
The introduction of sex-specific (SS) knee prosthesis designs was an approach to offer more sizing options and is based on the anatomic sex differences. Thes...
Stereotactic Cones in a 6MV Flattening Filter-free Beam: A Dosimetric Comparison of Varian Cones on TrueBeam versus CyberKnife Cones
Stereotactic Cones in a 6MV Flattening Filter-free Beam: A Dosimetric Comparison of Varian Cones on TrueBeam versus CyberKnife Cones
Purpose:
Dosimetric comparison of conical collimator (CC) supplied by Varian Medical System on a TrueBeam (TB) for 6MV-flattening filter-free (FFF) beams versus...
The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty
The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty
Background: Anterior knee pain is a prevalent issue post total knee arthroplasty, often necessitating revision surgery. Various factors contribute to this complication, including p...
Investigating Pre-Operative Joint-Level Biomechanics in Partial versus Total Knee Arthroplasty
Investigating Pre-Operative Joint-Level Biomechanics in Partial versus Total Knee Arthroplasty
BackgroundWhile knee osteoarthritis (OA) is incurable, end-stage OA can be managed surgically with partial knee arthroplasty (PKA) or total knee arthroplasty (TKA). Most studies th...
Mid-Term Results of Two-stage Revision Total Knee Arthroplasty for Infected Total Knee Arthroplasty
Mid-Term Results of Two-stage Revision Total Knee Arthroplasty for Infected Total Knee Arthroplasty
Introduction. Today, knee arthroplasty is one of the most common surgical procedures. Infection after endoprosthetics is the most dangerous complication in patients who have underg...
Vitamin D and periprosthetic infection: Review of literature (Preprint)
Vitamin D and periprosthetic infection: Review of literature (Preprint)
BACKGROUND
Infections are rare events in arthroplasty surgeries, occurring in only 0.5% to 2% of procedures. It significantly impacts all involved parts (pa...

