Cavotricuspid isthmus ablation (CTIA) is an effective treatment for typical atrial flutter (AFL) with a recurrence rate of about 10%. A prospective multicentric registry (FLAI registry) has recently shown that a protocol including ‘point by point’ CTI ablation targeting an a quality lesion marker (Ablation Index AI) ≥ 500 and a maximum inter-lesion distance (ILD) measurement of ≤6 mm allowed an acute success rate of 98.3%. In this study, we aimed to describe the incidence and predictors of recurrence of both AFL and atrial fibrillation (AF) in a long-term follow-up of the patients enrolled in the FLAI registry.
Methods
The FLAI registry was a multicentric non-randomized study that enrolled 412 consecutive patients (mean age 64.9±9.8; 72.1% males; 27.7% with structural heart disease). Patients with typical AFL underwent an AI-guided cavotricuspid isthmus ablation. The procedures targeted an AI of 500 and an ILD measurement of ≤ 6mm. The primary endpoints were CTI ‘first pass’ block and persistent block after a 20-minute waiting period. The CTI bidirectional "first pass block" was reached in 355 patients (88.3%), whereas CTI block at the end of the waiting period was achieved in 405 patients (98.3%). No complications were reported.
The mean time of follow-up was 21±4.24 months and it was available for 397 patients. The FU included outpatient clinical evaluation, ECG and 24-h Holter ECG at three, six- and 12-months post-ablation, followed by an annual clinical evaluation and ECG. Documented ECG Atrial fibrillation events, in follow up, were also included in the data set.
Results
Atrial flutter recurrence: 22 AFL events were observed (5.5%) at 34 months. According to the Kaplan Meier analysis, the growth of recurrence rate was constant between 6 and 12 months, after 19 months recurrences were unlikely. At the univariate analysis predictors of AFL recurrence were: absence of bidirectional block after the waiting time period (p= 0,001); failure of the CTIA index procedure (p=<0,0005); ablation line lengths > 32 mm (p=0.,018), number of automatic ablation lesion tags (VISITAG) > 20 (p=0,.005) and At the increathe reported numbers of ‘g"gap’" in the ablation line lengths: the more the gaps increase the more the probability of AFL recurrence in FU increases (p=0.,037).
In the Multivariate aAnalysis, the independent predictors of AFL recurrence were: the procedural success and the number of VISITAG (OR =1.062)
Atrial fibrillation recurrence: 45 patients developed atrial fibrillation after CTI ablation (11.3%). In the multivariate analysis, the major independent predictor was a documented pre-procedural Afib and the risk increases with the younger age (< 53 yo).
Conclusions
The FLAI protocol is safe, reproducible and effective in the follow-up, with a long term success of 94,5%. The reported incidence of atrial fibrillation in FU was 11,3%
Oxford University Press (OUP)
Title: Long term success of cavotricuspid isthmus ablation guided by the ablation index: results of the FLAI registry
Description:
Abstract
Funding Acknowledgements
Type of funding sources: None.
Introduction
Cavotricuspid isthmus ablation (CTIA) is an effective treatment for typical atrial flutter (AFL) with a recurrence rate of about 10%.
A prospective multicentric registry (FLAI registry) has recently shown that a protocol including ‘point by point’ CTI ablation targeting an a quality lesion marker (Ablation Index AI) ≥ 500 and a maximum inter-lesion distance (ILD) measurement of ≤6 mm allowed an acute success rate of 98.
3%.
In this study, we aimed to describe the incidence and predictors of recurrence of both AFL and atrial fibrillation (AF) in a long-term follow-up of the patients enrolled in the FLAI registry.
Methods
The FLAI registry was a multicentric non-randomized study that enrolled 412 consecutive patients (mean age 64.
9±9.
8; 72.
1% males; 27.
7% with structural heart disease).
Patients with typical AFL underwent an AI-guided cavotricuspid isthmus ablation.
The procedures targeted an AI of 500 and an ILD measurement of ≤ 6mm.
The primary endpoints were CTI ‘first pass’ block and persistent block after a 20-minute waiting period.
The CTI bidirectional "first pass block" was reached in 355 patients (88.
3%), whereas CTI block at the end of the waiting period was achieved in 405 patients (98.
3%).
No complications were reported.
The mean time of follow-up was 21±4.
24 months and it was available for 397 patients.
The FU included outpatient clinical evaluation, ECG and 24-h Holter ECG at three, six- and 12-months post-ablation, followed by an annual clinical evaluation and ECG.
Documented ECG Atrial fibrillation events, in follow up, were also included in the data set.
Results
Atrial flutter recurrence: 22 AFL events were observed (5.
5%) at 34 months.
According to the Kaplan Meier analysis, the growth of recurrence rate was constant between 6 and 12 months, after 19 months recurrences were unlikely.
At the univariate analysis predictors of AFL recurrence were: absence of bidirectional block after the waiting time period (p= 0,001); failure of the CTIA index procedure (p=<0,0005); ablation line lengths > 32 mm (p=0.
,018), number of automatic ablation lesion tags (VISITAG) > 20 (p=0,.
005) and At the increathe reported numbers of ‘g"gap’" in the ablation line lengths: the more the gaps increase the more the probability of AFL recurrence in FU increases (p=0.
,037).
In the Multivariate aAnalysis, the independent predictors of AFL recurrence were: the procedural success and the number of VISITAG (OR =1.
062)
Atrial fibrillation recurrence: 45 patients developed atrial fibrillation after CTI ablation (11.
3%).
In the multivariate analysis, the major independent predictor was a documented pre-procedural Afib and the risk increases with the younger age (< 53 yo).
Conclusions
The FLAI protocol is safe, reproducible and effective in the follow-up, with a long term success of 94,5%.
The reported incidence of atrial fibrillation in FU was 11,3%.
Related Results
The anatomy investigation of cavotricuspid isthmus linear ablation navigated by CARTO
The anatomy investigation of cavotricuspid isthmus linear ablation navigated by CARTO
Objective
We sought to investigate the anatomy characteristics of cavotricuspid isthmus (CTI) and its influence on linear ablation navigated by CARTO in patients ...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Cavotricuspid Isthmus-Dependent Atrial Flutter. Beyond Simple Linear Ablation
Cavotricuspid Isthmus-Dependent Atrial Flutter. Beyond Simple Linear Ablation
The demonstration of a peritricuspid circular movement with a zone of slow conduction in the cavotricuspid isthmus, together with the high efficacy of linear ablation and widely ac...
e0713 Evaluating successful ablation of scar-related atrial tachycardia originating at lateral wall of right atrium with a new method: strategic linear ablation to scar area isolation
e0713 Evaluating successful ablation of scar-related atrial tachycardia originating at lateral wall of right atrium with a new method: strategic linear ablation to scar area isolation
Background
Scar-related Intra-atrial re-entrant tachycardias (IARTs) located at lateral wall of right atrium are common late after cardiac surgery in which right ...
Tricuspid Regurgitation Following Cavotricuspid Isthmus Ablation: A Case Report
Tricuspid Regurgitation Following Cavotricuspid Isthmus Ablation: A Case Report
Introduction:
Tricuspid valve prolapse (TVP) is characterized by the tricuspid valve leaflets’ displacement beyond the annular plane during midsystole. Although less co...
The Tympanic Isthmus: Its Anatomy And Clinical Significance
The Tympanic Isthmus: Its Anatomy And Clinical Significance
The tympanic isthmus is a narrow passage between the tubotympanic cavity and the atticomastoid air space. Obstruction of the tympanic isthmus is frequent in various types of middle...
Ablation index-guided ablation with milder targets for atrial fibrillation: Comparison between high power and low power ablation
Ablation index-guided ablation with milder targets for atrial fibrillation: Comparison between high power and low power ablation
BackgroundHigh power-ablation index (HP-AI)-guided ablation for atrial fibrillation (AF) targeting high AIs has been implemented in European countries. However, milder AI targets a...
Ablation Performance of C/SiC-ZrC Composites
Ablation Performance of C/SiC-ZrC Composites
Abstract
To reveal the ablation performance of C/SiC-ZrC composites under different ablation methods, C/SiC-ZrC composites were prepared by chemical vapor deposition and pr...