Javascript must be enabled to continue!
Experimental Investigation of Evaporation and Condensation in Herringbone, Smooth and EHT Tubes
View through CrossRef
An experimental investigation was performed for evaporation and condensation characteristics inside smooth tube, herringbone tube and EHT tube with the same outer diameter 12.7 mm, refrigerant are R22 and R410a. Mass flux are 60–140 kg/m2s, 81–178.5 kg/m2s, for evaporation and condensation respectively. The evaporation saturation temperature is 6°C, with inlet and outlet vapor qualities of 0.1 and 0.9, respectively. The condensation saturation temperature is 47°C, with inlet and outlet vapor qualities of 0.8 and 0.2, respectively. EHT tube has best evaporating performance for both R22 and R410a. Herringbone tube is also batter than smooth tube. Evaporation heat transfer coefficient increases with mass flux increasing obviously. Pressure drop of R22 evaporation in EHT tube is the highest, herringbone tube is a little higher than in smooth tube. Herringbone tube has highest condensation heat transfer coefficient, about 3 and 2.3 times that of smooth tube for R22 and R410a respectively. EHT tube has heat transfer coefficient about 2 and 1.8 times that of smooth tube for R22 and R410a respectively. Condensation heat transfer coefficient increases with increasing of mass flux, but very slowly, R410a flow in micro-fin tube even decreases with mass flux increasing.
American Society of Mechanical Engineers
Title: Experimental Investigation of Evaporation and Condensation in Herringbone, Smooth and EHT Tubes
Description:
An experimental investigation was performed for evaporation and condensation characteristics inside smooth tube, herringbone tube and EHT tube with the same outer diameter 12.
7 mm, refrigerant are R22 and R410a.
Mass flux are 60–140 kg/m2s, 81–178.
5 kg/m2s, for evaporation and condensation respectively.
The evaporation saturation temperature is 6°C, with inlet and outlet vapor qualities of 0.
1 and 0.
9, respectively.
The condensation saturation temperature is 47°C, with inlet and outlet vapor qualities of 0.
8 and 0.
2, respectively.
EHT tube has best evaporating performance for both R22 and R410a.
Herringbone tube is also batter than smooth tube.
Evaporation heat transfer coefficient increases with mass flux increasing obviously.
Pressure drop of R22 evaporation in EHT tube is the highest, herringbone tube is a little higher than in smooth tube.
Herringbone tube has highest condensation heat transfer coefficient, about 3 and 2.
3 times that of smooth tube for R22 and R410a respectively.
EHT tube has heat transfer coefficient about 2 and 1.
8 times that of smooth tube for R22 and R410a respectively.
Condensation heat transfer coefficient increases with increasing of mass flux, but very slowly, R410a flow in micro-fin tube even decreases with mass flux increasing.
Related Results
Prediction of Condensation in the Heat Exchangers of Engine Intake Systems according to External Environmental and Operating Conditions
Prediction of Condensation in the Heat Exchangers of Engine Intake Systems according to External Environmental and Operating Conditions
Low-pressure exhaust gas recirculation (LP-EGR) systems are applied to diesel engines because they reduce nitrogen oxide emission by lowering the internal temperature of the cylind...
Evaluation of New Submillimeter VLBI Sites for the Event Horizon Telescope
Evaluation of New Submillimeter VLBI Sites for the Event Horizon Telescope
Abstract
The Event Horizon Telescope (EHT) is a very long-baseline interferometer built to image supermassive black holes on event-horizon scales. In this paper, we ...
Numerical Investigation on the Heat Transfer Enhancement Behavior Outside Longitudinal Finned Tubes
Numerical Investigation on the Heat Transfer Enhancement Behavior Outside Longitudinal Finned Tubes
With the purpose of enhancement of heat transfer performance and reduction of the volume of steam generator (SG), a structure of longitudinal finned tubes was proposed to replace t...
Observed Impacts of Evaporation and Condensation on Scale and Monitoring as the Industry Drills Deeper and Hotter
Observed Impacts of Evaporation and Condensation on Scale and Monitoring as the Industry Drills Deeper and Hotter
Abstract
As oil and gas wells continue to be drilled into deeper and, therefore, hotter formations globally, a new appreciation for simple evaporation and condensati...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Evaporation Characteristics of Two Interacting Moving Droplets
Evaporation Characteristics of Two Interacting Moving Droplets
The droplet evaporation in sprays and clouds is largely influenced by the interacting surrounding droplets. This study presents a numerical investigation on the evaporation dynamic...
Model and simulation of liquid rocket organic gel spray droplet evaporation
Model and simulation of liquid rocket organic gel spray droplet evaporation
Gel propellant has the advantage of controllable flux as liquid propellant and long-term reservation as solid propellant, however, the evaporation and combustion problem of gel spr...
Exploring the unique challenges of presenting English Heritage’s castles to a contemporary audience
Exploring the unique challenges of presenting English Heritage’s castles to a contemporary audience
The seventy-nine castles in the care of English Heritage Trust (EHT) are some of the most visually stunning and historically important in the world. In recent years, EHT has explor...