A comparison of root canal preparations using stainless steel, Ni-Ti hand, and Ni-Ti engine-driven endodontic instruments – an in vitro study

View through CrossRef
The main advantage of nickel titanium instruments is that they permit canal preparation with less transportation and ledging. Hand used Ni-Ti and rotary Ni-Ti instruments have a wider range of elastic deformation and greater flexibility. The aim of the present study was to evaluate and compare the preparation time, loss of working length, apical transportation, instrument deformation and fracture with stainless steel, Ni-Ti hand and Ni-Ti rotary endodontic instruments. Fifty freshly extracted human mandibular molars with curved roots were collected and stored in 10% formalin. The samples were divided into 3 groups of 15 each. The access opening was made for each tooth and the biomechanical preparation was carried out using crown down pressureless technique in all the groups. Group I was instrumented with stainless steel files, group II with hand Ni-Ti and group III with Ni-Ti rotary files. The preparation time to enlarge each canal was recorded in minutes and seconds, which included only active instrumentation. Following preparation, the final length of each canal was subtracted from the original length to give the loss of working length. SEM photographs of the deformed and fractured instruments were taken. The apical transportation was measured using computer software (Microdraw 4.1). The readings were noted and statistically analyzed.The results of this in vitro study showed that the mean preparation time was less with Ni- Ti rotary (1.85 min) when compared to hand Ni-Ti (6.33) and stainless steel files (6.73), which was statistically significant. The loss of working length was more for stainless steel group which was statistically significant (P<0.05) when compared with the other 2 groups.One instrument in stainless steel and one in Ni-Ti rotary files were fractured. Only one instrument in stainless steel file deformed permanently. Apical transportation was found to be greater in stainless steel group than other groups (P<0.01) which was statistically significant. Considering the parameters in this study, Ni-Ti rotary files proved to perform better than the other two groups. Key words: Canal preparation; crown-down pressure less technique; double exposure radiographic technique. DOI: 10.3329/bjms.v9i4.6689Bangladesh Journal of Medical Science Vol.09 No.4 July 2010 pp.223-230
Title: A comparison of root canal preparations using stainless steel, Ni-Ti hand, and Ni-Ti engine-driven endodontic instruments – an in vitro study
Description:
The main advantage of nickel titanium instruments is that they permit canal preparation with less transportation and ledging.
Hand used Ni-Ti and rotary Ni-Ti instruments have a wider range of elastic deformation and greater flexibility.
The aim of the present study was to evaluate and compare the preparation time, loss of working length, apical transportation, instrument deformation and fracture with stainless steel, Ni-Ti hand and Ni-Ti rotary endodontic instruments.
Fifty freshly extracted human mandibular molars with curved roots were collected and stored in 10% formalin.
The samples were divided into 3 groups of 15 each.
The access opening was made for each tooth and the biomechanical preparation was carried out using crown down pressureless technique in all the groups.
Group I was instrumented with stainless steel files, group II with hand Ni-Ti and group III with Ni-Ti rotary files.
The preparation time to enlarge each canal was recorded in minutes and seconds, which included only active instrumentation.
Following preparation, the final length of each canal was subtracted from the original length to give the loss of working length.
SEM photographs of the deformed and fractured instruments were taken.
The apical transportation was measured using computer software (Microdraw 4.
1).
The readings were noted and statistically analyzed.
The results of this in vitro study showed that the mean preparation time was less with Ni- Ti rotary (1.
85 min) when compared to hand Ni-Ti (6.
33) and stainless steel files (6.
73), which was statistically significant.
The loss of working length was more for stainless steel group which was statistically significant (P<0.
05) when compared with the other 2 groups.
One instrument in stainless steel and one in Ni-Ti rotary files were fractured.
Only one instrument in stainless steel file deformed permanently.
Apical transportation was found to be greater in stainless steel group than other groups (P<0.
01) which was statistically significant.
Considering the parameters in this study, Ni-Ti rotary files proved to perform better than the other two groups.
Key words: Canal preparation; crown-down pressure less technique; double exposure radiographic technique.
DOI: 10.
3329/bjms.
v9i4.
6689Bangladesh Journal of Medical Science Vol.
09 No.
4 July 2010 pp.
223-230.

Related Results

Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
Clinical and radiographic assessment of root canal treatments performed by dental students
Clinical and radiographic assessment of root canal treatments performed by dental students
Retrospective assessment of procedures performed in dental school clinics is a valuable tool to critically assess the teaching/ learning process. Objective: This retrospective stud...
Morpho-functionality of the toothed whale external ear canal
Morpho-functionality of the toothed whale external ear canal
While marine, anthropogenic noise pollution is a scientific and societal matter of concern, there is limited knowledge on how sea animals, particularly cetaceans, perceive their en...
Clad Steel Pipe for Corrosive Gas Transportation
Clad Steel Pipe for Corrosive Gas Transportation
ABSTRACT This paper describes the applicability and reliability Of clad steel pipe and its welds in sour gas environments in comparison with those of 22%Cr-5.5%Ni...
Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System—An In Vitro Study
Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System—An In Vitro Study
This study aimed at analyzing and comparing the ease of removal of fractured nickel–titanium (NiTi) endodontic rotary files from the root canal system between the ultrasonic tips a...
EFFECT OF INTRACANAL CRYOTHERAPY ON THE POST ENDODONTIC PAIN IN TEETH WITH SYMPTOMATIC APICAL PERIODONTITIS
EFFECT OF INTRACANAL CRYOTHERAPY ON THE POST ENDODONTIC PAIN IN TEETH WITH SYMPTOMATIC APICAL PERIODONTITIS
Objectives: To compare the effect of cryotherapy, room temperature saline and no saline as final root canal irrigants on post-endodontic pain in patients with symptomatic apical pe...
AN EFFECT OF APICAL PREPARATION ON THE QUALITY OF ENDODONTIC TREATMENT
AN EFFECT OF APICAL PREPARATION ON THE QUALITY OF ENDODONTIC TREATMENT
Relevance: The apical third of the root canal is difficult to access for high-quality endodontic treatment due to the complex anatomical and morphological structure of this area, w...

Back to Top