Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Performance of Unreinforced Masonry Walls in Compression: A Review of Design Provisions, Experimental Research, and Future Needs

View through CrossRef
Unreinforced masonry (URM) is a construction of brick or concrete block unit that is joined together using mortar, without steel reinforcement. Because of the heterogeneous nature and difference in mechanical properties of the masonry elements, analyzing and capturing the structural behaviour of URM walls under various loading conditions is therefore complex. In recent decades, research efforts have been focused on addressing and understanding the compressive behaviour of URM walls from the experimental viewpoint. However, from the existing experimental literature, there is a significant degree of variation in the mechanical and geometric properties of URM walls, especially the comprehensive comparison of apparently equivalent test parameters, which has yet to be examined. It is therefore necessary to highlight and critically examine major results derived from the experimental literature to better understand the performance of URM walls under compressive loads. This review paper presents the assessment performance with regard to axial compressive tests on URM walls, along with comprehensive comparisons among the experimental literature findings on the basis of masonry construction methods and various influencing parameters. Emphasis in the literature has been placed chiefly on the masonry elements, design provisions, axial load, slenderness ratio, openings, and stress–strain response. Based on observations from the study, experimental development trends have been highlighted to identify and outline potential directions for future studies.
Title: Performance of Unreinforced Masonry Walls in Compression: A Review of Design Provisions, Experimental Research, and Future Needs
Description:
Unreinforced masonry (URM) is a construction of brick or concrete block unit that is joined together using mortar, without steel reinforcement.
Because of the heterogeneous nature and difference in mechanical properties of the masonry elements, analyzing and capturing the structural behaviour of URM walls under various loading conditions is therefore complex.
In recent decades, research efforts have been focused on addressing and understanding the compressive behaviour of URM walls from the experimental viewpoint.
However, from the existing experimental literature, there is a significant degree of variation in the mechanical and geometric properties of URM walls, especially the comprehensive comparison of apparently equivalent test parameters, which has yet to be examined.
It is therefore necessary to highlight and critically examine major results derived from the experimental literature to better understand the performance of URM walls under compressive loads.
This review paper presents the assessment performance with regard to axial compressive tests on URM walls, along with comprehensive comparisons among the experimental literature findings on the basis of masonry construction methods and various influencing parameters.
Emphasis in the literature has been placed chiefly on the masonry elements, design provisions, axial load, slenderness ratio, openings, and stress–strain response.
Based on observations from the study, experimental development trends have been highlighted to identify and outline potential directions for future studies.

Related Results

Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Atypical business law provisions
Atypical business law provisions
The article is devoted to the vision of atypical business law provisions. It was found that the state of scientific opinion regarding atypical business law provisions is irrelevant...
Engineering Design Provisions for Prestressed Masonry, Part 1 – Masonry Stresses
Engineering Design Provisions for Prestressed Masonry, Part 1 – Masonry Stresses
Masonry can be strengthened through controlled precompression stresses which reduce or eliminate tension. In other countries, primarily the United Kingdom, prestressed masonry has ...
The Masonry Market is Booming in Brazil- Why?
The Masonry Market is Booming in Brazil- Why?
This paper is motivated by the keynote presentation at the 12th North American Masonry Conference in Denver, Colorado in 2015. It gives an overview on how engineered masonry became...
Experimental Comparison Between Two-Course Molded Masonry Specimen and Three-Course Extracted Masonry Specimen in Clay Masonry Structures
Experimental Comparison Between Two-Course Molded Masonry Specimen and Three-Course Extracted Masonry Specimen in Clay Masonry Structures
This study investigates the relationship between the compressive strength results of two-course molded masonry specimens and three-course masonry specimens extracted from previousl...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Estudio experimental y numérico del fallo por inestabilidad de muros de obra de fábrica
Estudio experimental y numérico del fallo por inestabilidad de muros de obra de fábrica
A large part of the building stock of the Spanish and European cities consists of load-bearing wall buildings made of brick masonry. The structural safety of such constructions, ...
Seismic Capacity Assessment of Confined Brick Masonry Building: An Experimental Approach
Seismic Capacity Assessment of Confined Brick Masonry Building: An Experimental Approach
Brick masonry is widely used for building construction throughout the world. However, unreinforced brick masonry buildings performed poorly in the 2005 Kashmir earthquake, in Pakis...

Back to Top