Javascript must be enabled to continue!
A miniaturized acoustic vector sensor with PIN-PMN-PT single crystal cantilever beam accelerometers
View through CrossRef
Directional sound detection using vector sensors rather than large hydrophone arrays is highly advantageous for target detection in SONAR. However, developing highly sensitive and compact vector sensors for use in a system whose size is limited has been a challenging issue. In this paper, we describe a miniaturized acoustic vector sensor with piezoelectric single crystal accelerometers for the application in towed line arrays. A mass-loaded cantilever beam accelerometer with a [011] poled PIN-PMN-PT single crystal shows a better signal-to-noise ratio compared to accelerometers with other piezoelectric materials because of its superior piezoelectric properties in the 32 direction. We suggested a sufficiently compact vector sensor by using a cylindrical hydrophone with 10 mm in diameter as a housing of the single crystal accelerometers. Two single crystal accelerometers were orthogonally mounted inside the cylindrical hydrophone to detect direction of sound in the transverse plane of the line array. The receiving voltage sensitivity of the accelerometers and hydrophone was −199 and −196 dB, respectively, at 3 kHz. The directional cardioid beams generated by summing the omnidirectional beam from the hydrophone and the dipole beam from the accelerometers were validated over the entire operating frequency.
Title: A miniaturized acoustic vector sensor with PIN-PMN-PT single crystal cantilever beam accelerometers
Description:
Directional sound detection using vector sensors rather than large hydrophone arrays is highly advantageous for target detection in SONAR.
However, developing highly sensitive and compact vector sensors for use in a system whose size is limited has been a challenging issue.
In this paper, we describe a miniaturized acoustic vector sensor with piezoelectric single crystal accelerometers for the application in towed line arrays.
A mass-loaded cantilever beam accelerometer with a [011] poled PIN-PMN-PT single crystal shows a better signal-to-noise ratio compared to accelerometers with other piezoelectric materials because of its superior piezoelectric properties in the 32 direction.
We suggested a sufficiently compact vector sensor by using a cylindrical hydrophone with 10 mm in diameter as a housing of the single crystal accelerometers.
Two single crystal accelerometers were orthogonally mounted inside the cylindrical hydrophone to detect direction of sound in the transverse plane of the line array.
The receiving voltage sensitivity of the accelerometers and hydrophone was −199 and −196 dB, respectively, at 3 kHz.
The directional cardioid beams generated by summing the omnidirectional beam from the hydrophone and the dipole beam from the accelerometers were validated over the entire operating frequency.
Related Results
Polymorphonuclear Oxidative Burst after Helicobacter pylori Water Extract Stimulation Is not Influenced by the Cytotoxic Genotype but Indicates Infection and Gastritis Grade
Polymorphonuclear Oxidative Burst after Helicobacter pylori Water Extract Stimulation Is not Influenced by the Cytotoxic Genotype but Indicates Infection and Gastritis Grade
Abstract
H. pylori-associated gastric mucosal inflammation is
characterized by the presence of polymorphonuclear
(PMN) leukocyte infiltrate, which...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Dynamics of leukocyte-platelet adhesion in whole blood
Dynamics of leukocyte-platelet adhesion in whole blood
The dynamics of leukocyte-platelet adhesion and platelet-platelet interaction in whole blood are not well understood. Using different platelet agonists, we have studied the whole b...
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
The dynamical motion at any point on the cantilever of an atomic force microscope can be expressed quite generally as a superposition of simple harmonic oscillators corresponding t...
PIN-PMN-PT Single Crystal 1-3 Composite based 20 MHz Ultrasound Phased Array
PIN-PMN-PT Single Crystal 1-3 Composite based 20 MHz Ultrasound Phased Array
Based on a modified dice-and-fill technique, a PIN-PMN-PT single crystal 1-3 composite with the kerf of 12μm and pitch of 50μm was prepared. The as-made piezoelectric composite mat...
Analisa Tegangan Kerusakan pada Pin Hopper
Analisa Tegangan Kerusakan pada Pin Hopper
Hopper pada Stage Regenerator mengalami kerusakan berupa jatuh dan robek. Hal ini disebabkan karena lepasnya salah satu pin yang menjadi tumpuan hopper. Setela...
Optimal arrangement of four‐sensor dynamic acoustic array
Optimal arrangement of four‐sensor dynamic acoustic array
PurposeThe purpose of this paper is to demonstrate the theoretical relationship between the layout of four‐sensor dynamic acoustic array tracking system and systematic observation ...
Novel Cantilever Sensor for Antibody-based and hlyA gene-based Sensitive Detection of Foodborne Pathogen
Novel Cantilever Sensor for Antibody-based and hlyA gene-based Sensitive Detection of Foodborne Pathogen
The objectives of this research can be broadly categorized as: 1) Cantilever sensor design and characteristics, 2) Improved surface chemistry for immobilization of recognition mole...


