Javascript must be enabled to continue!
SU‐GG‐T‐149: 4D IMRT Quality Assurance (QA) by Dynamic Log File Analysis
View through CrossRef
Purpose: 4D IMRT was a technique developed to account for dosimetry errors from intra‐fraction motion, especially from anatomy transformation caused by respiration. To perform 4D IMRT dose validation some dynamic phantoms are used. Measurements with dynamic phantom involve the complex setting procedure. In order to simplify the QA procedure and quickly check the IMRT plan, a 4D IMRT verification tool was developed. The delivered fluence map to a moving target can be simulated from dynamic log (Dynalog) files using this tool. Method and Materials: A 4D CT was acquired for the patient. The breathing cycle was divided into 10 phases. An IMRT plan was generated for the exhale phase, and its leaf sequence was exported. The original leaf sequence was modified by superimposing the tumor trajectory onto the leaf trajectory in a two dimensional beam's eye view plane. The modified leaf sequence was delivered by Varian 2100 CD with Millenium 120 leaf MLC. After dose delivery Dynalog files were analyzed by an in‐house software to simulate the fluence map of a moving target. The fluence map measured by the dynamic phantom was compared with the simulation of delivered fluence map. Results: The comparison between the measured fluence map using the dynamic phantom and the simulated fluence map by Dynalog files shows that the difference of isodose lines was within 3mm and the difference of line profiles was within 3%. Conclusion: A 4D IMRT QA tool was developed to simulate the delivered fluence map to a moving target. The simulated fluence map shows a good agreement with the measured fluence map based on dynamic phantom measurements. When compared to phantom measurement, this tool can assist to quickly check the 4D IMRT plan and handle irregular tumor trajectories.
Title: SU‐GG‐T‐149: 4D IMRT Quality Assurance (QA) by Dynamic Log File Analysis
Description:
Purpose: 4D IMRT was a technique developed to account for dosimetry errors from intra‐fraction motion, especially from anatomy transformation caused by respiration.
To perform 4D IMRT dose validation some dynamic phantoms are used.
Measurements with dynamic phantom involve the complex setting procedure.
In order to simplify the QA procedure and quickly check the IMRT plan, a 4D IMRT verification tool was developed.
The delivered fluence map to a moving target can be simulated from dynamic log (Dynalog) files using this tool.
Method and Materials: A 4D CT was acquired for the patient.
The breathing cycle was divided into 10 phases.
An IMRT plan was generated for the exhale phase, and its leaf sequence was exported.
The original leaf sequence was modified by superimposing the tumor trajectory onto the leaf trajectory in a two dimensional beam's eye view plane.
The modified leaf sequence was delivered by Varian 2100 CD with Millenium 120 leaf MLC.
After dose delivery Dynalog files were analyzed by an in‐house software to simulate the fluence map of a moving target.
The fluence map measured by the dynamic phantom was compared with the simulation of delivered fluence map.
Results: The comparison between the measured fluence map using the dynamic phantom and the simulated fluence map by Dynalog files shows that the difference of isodose lines was within 3mm and the difference of line profiles was within 3%.
Conclusion: A 4D IMRT QA tool was developed to simulate the delivered fluence map to a moving target.
The simulated fluence map shows a good agreement with the measured fluence map based on dynamic phantom measurements.
When compared to phantom measurement, this tool can assist to quickly check the 4D IMRT plan and handle irregular tumor trajectories.
Related Results
miR-149 rs2292832 C allele enhances the cytotoxic effect of temozolomide against glioma cells
miR-149 rs2292832 C allele enhances the cytotoxic effect of temozolomide against glioma cells
Glioma is a common cancer that affects people worldwide with high morbidity and mortality. Human miR-149 rs2292832 C/T polymorphism and miR-149-5p expressions have been documented ...
Dosimetric comparisons of intensity‐modulated radiation therapy and three‐dimensional conformal radiation therapy for left‐sided breast cancer after radical surgery
Dosimetric comparisons of intensity‐modulated radiation therapy and three‐dimensional conformal radiation therapy for left‐sided breast cancer after radical surgery
AbstractObjectivePostoperative radiotherapy for breast cancer is an effective way to control tumor recurrence; however, there are advantages and disadvantages to different radiothe...
XII Congresso da Sociedade Brasileira de Radioterapia (SBRT); X Jornada de Física Médica; VIII Encontro de Enfermeiros Oncologistas em Radioterapia; VII Encontro de Técnicos em Radioterapia da SBRT
XII Congresso da Sociedade Brasileira de Radioterapia (SBRT); X Jornada de Física Médica; VIII Encontro de Enfermeiros Oncologistas em Radioterapia; VII Encontro de Técnicos em Radioterapia da SBRT
Resumos escolhidos para publicação. Nessa edição, os títulos foram: Resposta das Células da Medula Óssea Submetidas ao Tratamento com a-tocoferol e Radiação, in vivo; Câncer de Mam...
XIII Congresso da Sociedade Brasileira de Radioterapia (SBRT); II Encontro de Residentes em Radioterapia da SBRT; XI Jornada de Física Médica; IX Encontro de Enfermeiros Oncologistas em Radioterapia; VIII Encontro de Técnicos em Radioterapia
XIII Congresso da Sociedade Brasileira de Radioterapia (SBRT); II Encontro de Residentes em Radioterapia da SBRT; XI Jornada de Física Médica; IX Encontro de Enfermeiros Oncologistas em Radioterapia; VIII Encontro de Técnicos em Radioterapia
Resumos escolhidos para publicação. Nessa edição, os títulos foram: Níveis de Selênio Plasmático antes e após Radioterapia no Câncer de Próstata; Avaliação Digital de Imagens Derma...
Comparative evaluation of the effect of glide path creation with Nitiflex hand K- file, Proglider and Path file on canal transportation and concentricity in apically curved canals - An In- Vitro study.
Comparative evaluation of the effect of glide path creation with Nitiflex hand K- file, Proglider and Path file on canal transportation and concentricity in apically curved canals - An In- Vitro study.
Abstract
Aim:
To compare and evaluate the effect of glide path creation with Nitiflex hand K- file, Proglider and Path file on canal transportation and concentricity in...
SU‐GG‐T‐572: Are Constant Dose Rate VMAT Plans Clinically Acceptable? — A Site‐By‐Site Plan Comparison Study
SU‐GG‐T‐572: Are Constant Dose Rate VMAT Plans Clinically Acceptable? — A Site‐By‐Site Plan Comparison Study
Purpose: To evaluate the adequacy of constant dose rate (CDR) VMAT plans for clinical use of commonly treated sites. The clinical acceptability of CDR VMAT plans was evaluated base...
Creating Secure File Systems in Open-Source Operating Systems
Creating Secure File Systems in Open-Source Operating Systems
The relevance of this study is determined by insecure data storage on personal computers, as it is the main operating system that performs authentication and file access control. B...

