Javascript must be enabled to continue!
Utilizing the high shunt impedance TM020-mode cavity in the double RF systems for the storage ring of the Thailand new light source
View through CrossRef
Abstract
The utilization of the TM020-mode cavity for the storage ring based light source was pioneered by SPring-8 with its high quality factor and hence its high shunt impedance. KEK-LS has also studied the possibility of using this type of cavity for their storage ring. The TM020-mode cavity has larger transverse dimension compared to the traditional TM010-mode cavity, but with its higher shunt impedance it can be designed to fit in the new low emittance storage ring regardless. The new storage ring based light source project in Thailand aims to optimum the low emittance beam in nano-meters region with the energy of 3 GeV. The TM020-mode cavity was considered as the main cavity and the harmonic cavity for the storage ring. They have been designed to have their pipe aperture fits the storage ring beam ducts. The main cavity has a high shunt impedance of 8.3 MΩ with the 51,000 unloaded quality factor. The harmonic cavity has a high shunt impedance and an unloaded quality factor of 2.45 MΩ and 36,000, respectively. The damping mechanism of the parasitic modes and the tuning mechanism of the operating mode of these cavities were also studied. There will be four main cavities and six harmonic cavities in the new storage ring. Detailed design and study of these cavities will be presented.
IOP Publishing
Title: Utilizing the high shunt impedance TM020-mode cavity in the double RF systems for the storage ring of the Thailand new light source
Description:
Abstract
The utilization of the TM020-mode cavity for the storage ring based light source was pioneered by SPring-8 with its high quality factor and hence its high shunt impedance.
KEK-LS has also studied the possibility of using this type of cavity for their storage ring.
The TM020-mode cavity has larger transverse dimension compared to the traditional TM010-mode cavity, but with its higher shunt impedance it can be designed to fit in the new low emittance storage ring regardless.
The new storage ring based light source project in Thailand aims to optimum the low emittance beam in nano-meters region with the energy of 3 GeV.
The TM020-mode cavity was considered as the main cavity and the harmonic cavity for the storage ring.
They have been designed to have their pipe aperture fits the storage ring beam ducts.
The main cavity has a high shunt impedance of 8.
3 MΩ with the 51,000 unloaded quality factor.
The harmonic cavity has a high shunt impedance and an unloaded quality factor of 2.
45 MΩ and 36,000, respectively.
The damping mechanism of the parasitic modes and the tuning mechanism of the operating mode of these cavities were also studied.
There will be four main cavities and six harmonic cavities in the new storage ring.
Detailed design and study of these cavities will be presented.
Related Results
Uncommon complications of ventriculoperitoneal shunt surgery: review of four cases and literature review
Uncommon complications of ventriculoperitoneal shunt surgery: review of four cases and literature review
Abstract
Background
Ventriculoperitoneal shunt is one of the most popular cerebrospinal fluid diversion procedures worldwide. Complications are common, but uncommon complications a...
ANALYSIS OF THE TREATMENT RESULTS OF COMPLICATIONS OF VENTRICULOPERITONEAL SHUNTING SURGERY IN CHILDREN
ANALYSIS OF THE TREATMENT RESULTS OF COMPLICATIONS OF VENTRICULOPERITONEAL SHUNTING SURGERY IN CHILDREN
The purpose of this study was to analyze the demographic data of children who had complications associated with ventriculoperitoneal shunt surgery and to review the clinical charac...
Indications of ventriculoperitoneal shunt: a prospective study
Indications of ventriculoperitoneal shunt: a prospective study
Background: Shunts have been used to drain the Cerebrospinal fluid into practically every body cavity, organ system and tissue spaces. Scraff has critically reviewed the efficacy o...
Assessing the Effectiveness of Neuro-Endoscopic Procedures in the Treatment of Hydrocephalus
Assessing the Effectiveness of Neuro-Endoscopic Procedures in the Treatment of Hydrocephalus
Objective: The purpose of this systematic study is to assess the mortality results of early vs. delayed VP shunt implantation for hydrocephalus caused by myelomeningocele and exami...
Cerebrospinal Fluid Shunt Complications after Urological Procedures in Children with Myelodysplasia
Cerebrospinal Fluid Shunt Complications after Urological Procedures in Children with Myelodysplasia
ABSTRACT
OBJECTIVE
Invasive urological procedures, commonly performed on patients with myelodysplasia, may contribute to the occ...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Ventriculoportal Shunt, a New Transomphalic Extraperitoneal Surgical Technique in Treatment of Hydrocephalus
Ventriculoportal Shunt, a New Transomphalic Extraperitoneal Surgical Technique in Treatment of Hydrocephalus
Aim. The aim of this article was to report a new transomphalic extraperitoneal surgical technique for treatment of hydrocephalus, called ventriculoportal shunt. Materials and Metho...
A Prospective Study On Ventriculoperitoneal Shunt Surgery Complications In Tertiary Care Hospital
A Prospective Study On Ventriculoperitoneal Shunt Surgery Complications In Tertiary Care Hospital
Background and Aim: Hydrocephalus is defined as enlargement in ventricles size due to the increase in cerebrospinal fluid volume. Impaired cerebrospinal fluids in terms of absorpti...

