Evaluation of temperature of a full ceramic total knee arthroplasty during MRI examinations

View through CrossRef
Background: A diagnosis by magnetic resonance imaging (MRI) is often necessary before surgery of degenerative spine diseases. This can lead to a possible conflict with an inserted implant of the hip or knee. Heat generation or movement could be caused by the magnetic field. The aim of this study is to investigate temperature development in vitro in a 1.5T MRI of a ceramic knee arthroplasty. Methods: A full ceramic, complete metal-free non-constrained primary total knee arthroplasty is investigated. Temperature change was measured between platinum resistors before and after each MRI sequence by change of resistance. The knee implant was placed in a plastic container after the sensors were attached. Then the container was completely filled with ultrasound gel. To document any possible movement of the implant, a grid was placed under the container to document the position of the implant before and after the scans. Results: A total of four standard knee sequences were performed. The temperature at sites 1 to 5 per implant was always documented in the as-is state before MRI and then after each sequence. A total of 5 temperature measurement points were taken per implant. It was found that there were extremely small temperature variations. These were always in the range of less than 1°C. There was no case of movement of the implant triggered by the MRI scan. Conclusions: The experimental investigations carried out here showed homogeneous results with this experimental setup. It is concluded that, at least in vitro, that this ceramic knee implant can be used in MRI examinations without heating or movement.
Title: Evaluation of temperature of a full ceramic total knee arthroplasty during MRI examinations
Description:
Background: A diagnosis by magnetic resonance imaging (MRI) is often necessary before surgery of degenerative spine diseases.
This can lead to a possible conflict with an inserted implant of the hip or knee.
Heat generation or movement could be caused by the magnetic field.
The aim of this study is to investigate temperature development in vitro in a 1.
5T MRI of a ceramic knee arthroplasty.
Methods: A full ceramic, complete metal-free non-constrained primary total knee arthroplasty is investigated.
Temperature change was measured between platinum resistors before and after each MRI sequence by change of resistance.
The knee implant was placed in a plastic container after the sensors were attached.
Then the container was completely filled with ultrasound gel.
To document any possible movement of the implant, a grid was placed under the container to document the position of the implant before and after the scans.
Results: A total of four standard knee sequences were performed.
The temperature at sites 1 to 5 per implant was always documented in the as-is state before MRI and then after each sequence.
A total of 5 temperature measurement points were taken per implant.
It was found that there were extremely small temperature variations.
These were always in the range of less than 1°C.
There was no case of movement of the implant triggered by the MRI scan.
Conclusions: The experimental investigations carried out here showed homogeneous results with this experimental setup.
It is concluded that, at least in vitro, that this ceramic knee implant can be used in MRI examinations without heating or movement.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Evaluation of knee articular cartilage through calcium-suppressed technique in dual-energy computed tomography
Evaluation of knee articular cartilage through calcium-suppressed technique in dual-energy computed tomography
Objectives: The evaluation of knee articular cartilage is of paramount importance in diagnosing and managing musculoskeletal disorders. Accurate and non-invasive imaging techniques...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...
The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty
The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty
Background: Anterior knee pain is a prevalent issue post total knee arthroplasty, often necessitating revision surgery. Various factors contribute to this complication, including p...
Complications of revision knee arthroplasty
Complications of revision knee arthroplasty
Due to the growing scale of arthroplasty and the widening of indications for knee joint replacement, the durability of joint functioning has become a critical issue. Untimely diagn...
Mid-Term Results of Two-stage Revision Total Knee Arthroplasty for Infected Total Knee Arthroplasty
Mid-Term Results of Two-stage Revision Total Knee Arthroplasty for Infected Total Knee Arthroplasty
Introduction. Today, knee arthroplasty is one of the most common surgical procedures. Infection after endoprosthetics is the most dangerous complication in patients who have underg...
Femoral Component Survival in Hybrid Total Knee Arthroplasty
Femoral Component Survival in Hybrid Total Knee Arthroplasty
Although the majority of North American surgeons perform total knee arthroplasty by cementing both the femoral and the tibial components, hybrid fixation with a press-fit femur and...