Accuracy of Imaging the Menisci on an In-Office, Dedicated, Magnetic Resonance Imaging Extremity System*
View through CrossRef
Magnetic resonance imaging effectively defines and characterizes musculoskeletal pathologic lesions, par ticularly meniscal tears. Most studies comparing the efficacy of magnetic resonance imaging and arthro scopic evaluation have been performed on high-field (1.5-T) systems. The effectiveness of a low-field (0.2- T), dedicated, extremity magnetic resonance imaging device in diagnosing meniscal tears was studied pro spectively on 35 patients with knee symptoms who subsequently had arthroscopic evaluation. Magnetic resonance imaging examinations were performed be fore surgery and were read by an experienced radiol ogist who was blinded to the results of the arthroscopic evaluations. Specificity was 100% for both the medial and lateral menisci. Sensitivity was 86% for the medial menisci, 89% for the lateral menisci, and 87% for both. Accuracy was 91 % for the medial menisci, 97% for the lateral menisci, and 94% overall. The positive predic tive values were 100% for the medial menisci, 100% for the lateral menisci, and 100% for both. The nega tive predictive values were 81 % for the medial menisci, 96% for the lateral menisci, and 91 % for both. The low-field magnetic resonance imaging system provided specificity and sensitivity that were equal to or better than previous reports with high-field systems. In par ticular, this low-field system eliminated the problem of false-positive results that has been found in some stud ies using high-field systems.
Title: Accuracy of Imaging the Menisci on an In-Office, Dedicated, Magnetic Resonance Imaging Extremity System*
Description:
Magnetic resonance imaging effectively defines and characterizes musculoskeletal pathologic lesions, par ticularly meniscal tears.
Most studies comparing the efficacy of magnetic resonance imaging and arthro scopic evaluation have been performed on high-field (1.
5-T) systems.
The effectiveness of a low-field (0.
2- T), dedicated, extremity magnetic resonance imaging device in diagnosing meniscal tears was studied pro spectively on 35 patients with knee symptoms who subsequently had arthroscopic evaluation.
Magnetic resonance imaging examinations were performed be fore surgery and were read by an experienced radiol ogist who was blinded to the results of the arthroscopic evaluations.
Specificity was 100% for both the medial and lateral menisci.
Sensitivity was 86% for the medial menisci, 89% for the lateral menisci, and 87% for both.
Accuracy was 91 % for the medial menisci, 97% for the lateral menisci, and 94% overall.
The positive predic tive values were 100% for the medial menisci, 100% for the lateral menisci, and 100% for both.
The nega tive predictive values were 81 % for the medial menisci, 96% for the lateral menisci, and 91 % for both.
The low-field magnetic resonance imaging system provided specificity and sensitivity that were equal to or better than previous reports with high-field systems.
In par ticular, this low-field system eliminated the problem of false-positive results that has been found in some stud ies using high-field systems.
Related Results
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Isolated Upper Extremity Compartment Syndrome: A Case of Rhabdomyolysis-induced Myoglobinuria and Acute Kidney Injury after Opioid Overdose
Isolated Upper Extremity Compartment Syndrome: A Case of Rhabdomyolysis-induced Myoglobinuria and Acute Kidney Injury after Opioid Overdose
Introduction: The association between rhabdomyolysis secondary to traumatic crush injuries and the resultant acute kidney injury has been well described [1]. The pathway of opioid ...
Diagnostic Accuracy of Ultrasonography Versus Magnetic Resonance Imaging in the Detection of Endometrial Carcinoma Keeping Histopathology as Gold Standard
Diagnostic Accuracy of Ultrasonography Versus Magnetic Resonance Imaging in the Detection of Endometrial Carcinoma Keeping Histopathology as Gold Standard
Objective: To calculate the diagnostic accuracy of Ultrasonography versus Magnetic Resonance Imaging in detecting endometrial carcinoma with histopathology kept as a gold standard....
Fiber-reinforced, anisotropic superporous cryogels for meniscal replacement
Fiber-reinforced, anisotropic superporous cryogels for meniscal replacement
Menisci are anisotropic, semicircular fibrocartilaginous tissues that must withstand extensive loads and sustain adequate locomotion in the knee joints. Meniscal tears are the most...
Superior oblique myokymia: Magnetic resonance imaging support for the neurovascular compression hypothesis
Superior oblique myokymia: Magnetic resonance imaging support for the neurovascular compression hypothesis
AbstractSuperior oblique myokymia is a rare movement disorder thought to be caused by vascular compression of the trochlear nerve. Direct display of such neurovascular compression ...
Method of liquid consumption measuring in nuclear magnetic flowmeters-relaxometers
Method of liquid consumption measuring in nuclear magnetic flowmeters-relaxometers
The need to expand the functionality of systems for monitoring the parameters of the flow of liquid media is substantiated. The advantages of using meters based on the phenomenon o...
Localized nanoscale induction by single domain magnetic particles
Localized nanoscale induction by single domain magnetic particles
AbstractSingle domain magnetic nanoparticles are increasingly investigated as actuators of biological and chemical processes that respond to externally applied magnetic fields. Alt...
MR imaging of magnetic ink patterns via off‐resonance sensitivity
MR imaging of magnetic ink patterns via off‐resonance sensitivity
PurposePrinted magnetic ink creates predictable B0 field perturbations based on printed shape and magnetic susceptibility. This can be exploited for contrast in MR imaging techniqu...