Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Progress of joule balance and redifination of Kilogram

View through CrossRef
Kilogram, the unit of mass, is the last one of seven base units in International System of Units (SI) which is still defined and kept by a material artifact. 1 kg is defined as the mass of the International Prototype of the Kilogram (IPK) kept at the Bureau International des Poids et Mesures (BIPM) in Paris. One of the major disadvantages of this definition is the fact that the amount of material constituting the IPK changes with time. Because a more stable mass reference does not exist, the variation of IPK is completely unknown so far. The International Committee for Weights and Measures (CIPM) recommended redefining the kilogram by fixing the numerical value of the Planck constant h and called on every national metrology institute to study the measurement of the h. To avoid possible system errors from one method, more experiments especially based on different principles are expected and encouraged for the final determination of the Planck constant. The CCM required that at least three consistent results should be obtained before the redefinition. Since 1970 s, the Kibble balance (also known as the Kibble balance) experiment has been used by a number of national metrology institutes such as NPL, NIST, METAS, LNE and BIPM. The IAC including the PTB, NMIJ and NMIA used the XRCD method to measure the Avogadro constant. To make contribution to the redefinition of kilogram, the National Institute of Metrology of China (NIM) proposed a joule balance method in 2006, which is also an electrical way but different from the watt balance method in that the dynamic phase is replaced with a static phase to avoid the trouble in the dynamic measurement. The progress of these approaches and the current situation of the redefinition of the kilogram are presented in this paper. In 2013, a model apparatus was built to verify the principle of the joule balance. Then NIM started to build its new joule balance aiming to obtain an uncertainty of 10-8 level since 2013. In Dec. 2016, the new apparatus was built and could be used to measure the Planck constant h in vacuum. In May 2017, the measurement result was submitted to the Metrologia and accepted by the CODATA TGFC as the input data. However, the measurement result has an uncertainty bigger than 10-8 and was not used for the final determination of the h value. At present, the joule balance group of NIM, together with the Harbin Institute of Technology, Tsinghua University and China Jiliang University is still making great efforts to improve the joule balance apparatus. The uncertainty of 10-8 level is expected to be achieved in the next two years.
Title: Progress of joule balance and redifination of Kilogram
Description:
Kilogram, the unit of mass, is the last one of seven base units in International System of Units (SI) which is still defined and kept by a material artifact.
1 kg is defined as the mass of the International Prototype of the Kilogram (IPK) kept at the Bureau International des Poids et Mesures (BIPM) in Paris.
One of the major disadvantages of this definition is the fact that the amount of material constituting the IPK changes with time.
Because a more stable mass reference does not exist, the variation of IPK is completely unknown so far.
The International Committee for Weights and Measures (CIPM) recommended redefining the kilogram by fixing the numerical value of the Planck constant h and called on every national metrology institute to study the measurement of the h.
To avoid possible system errors from one method, more experiments especially based on different principles are expected and encouraged for the final determination of the Planck constant.
The CCM required that at least three consistent results should be obtained before the redefinition.
Since 1970 s, the Kibble balance (also known as the Kibble balance) experiment has been used by a number of national metrology institutes such as NPL, NIST, METAS, LNE and BIPM.
The IAC including the PTB, NMIJ and NMIA used the XRCD method to measure the Avogadro constant.
To make contribution to the redefinition of kilogram, the National Institute of Metrology of China (NIM) proposed a joule balance method in 2006, which is also an electrical way but different from the watt balance method in that the dynamic phase is replaced with a static phase to avoid the trouble in the dynamic measurement.
The progress of these approaches and the current situation of the redefinition of the kilogram are presented in this paper.
In 2013, a model apparatus was built to verify the principle of the joule balance.
Then NIM started to build its new joule balance aiming to obtain an uncertainty of 10-8 level since 2013.
In Dec.
2016, the new apparatus was built and could be used to measure the Planck constant h in vacuum.
In May 2017, the measurement result was submitted to the Metrologia and accepted by the CODATA TGFC as the input data.
However, the measurement result has an uncertainty bigger than 10-8 and was not used for the final determination of the h value.
At present, the joule balance group of NIM, together with the Harbin Institute of Technology, Tsinghua University and China Jiliang University is still making great efforts to improve the joule balance apparatus.
The uncertainty of 10-8 level is expected to be achieved in the next two years.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
ANALISIS PEMASARAN KEDELAI
ANALISIS PEMASARAN KEDELAI
Penelitian ini bertujuan untuk mengetahui: 1) saluran pemasaran kedelai dari produsen sampai ke konsumen; 2) besarnya biaya pemasaran, marjin pemasaran dan keuntungan pemasaran ked...
Thomson/Joule Power Compensation and the Measurement of the Thomson Coefficient
Thomson/Joule Power Compensation and the Measurement of the Thomson Coefficient
The energy transported by the electric current that circulates a thermoelectric element (TE) varies with position due to the Joule and Thomson effects. The Thomson effect may enhan...
The Influence of Feedback on Balance in Stroke Patients
The Influence of Feedback on Balance in Stroke Patients
Stroke has been recognized as one of the basic reasons what concerns illness, death-rate and long-term disability all over the world. Balance disorder is one of the most common dis...
Investigation of Anti- Pyretic Activity of Cinnamon Oil in Wistar Rat
Investigation of Anti- Pyretic Activity of Cinnamon Oil in Wistar Rat
The current exploration work was to explore the antipyretic movement of cinnamon oil (25 Milligram/ kilogram or 50 Milligram/ kilogram p.o). The antipyretic movement was assessed a...
RESEARCH ON STABILITY ANALYSIS OF INTERNATIONAL PROTOTYPE KILOGRAM
RESEARCH ON STABILITY ANALYSIS OF INTERNATIONAL PROTOTYPE KILOGRAM
Today, the kilogram is the last of the seven base units of the International System of Units (SI) which is based on a physical artifact. The demands of modern mass metrology have l...
Exploring the role of attention towards balance in chronic dizziness: Development of the Balance Vigilance Questionnaire (Balance-VQ)
Exploring the role of attention towards balance in chronic dizziness: Development of the Balance Vigilance Questionnaire (Balance-VQ)
AbstractBackground and ObjectivesVigilance towards balance has been proposed to underpin various chronic dizziness disorders, including Persistent Postural Perceptual Dizziness (PP...

Back to Top