Javascript must be enabled to continue!
Current Developments in Radiotherapy Quality Control Methods
View through CrossRef
Quality control is of critical importance to ensure the accurate and reliable implementation of treatment in radiotherapy. Radiotherapy is a primary method of treating diseases such as cancer, aiming to destroy cancer cells or control their growth using high-energy X-rays or gamma rays. The quality control process encompasses a comprehensive series of procedures involving regular examination and evaluation of elements like radiotherapy devices, dosimetric components, and treatment planning systems. The primary objectives of quality control are to enhance patient safety, ensure accurate dose delivery, and optimize treatment outcomes. Due to its inclusion of critical parameters and safety measures, this process holds significant importance in the field of radiotherapy.
The quality control process begins with the examination of treatment devices and components. Linear accelerators are the most commonly used devices in radiotherapy. Quality control procedures for linear accelerators involve various steps, including reference dose measurement, dose output calibration, isocenter dose measurements, accuracy of irradiation, beam profile control, and dynamic field control. The control of simulation and imaging devices such as CT simulation, MRI, PET/CT, and ultrasound plays a crucial role in radiotherapy preparation. The quality control of these devices ensures the accuracy of elements such as calibration, visualization of anatomical structures, and assessment of image quality.
Ion chambers, diode detectors, two-dimensional dosimeters, diamond detectors, thermoluminescent dosimeters (TLD), Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET) detectors, and gel dosimeters are used for the control of devices and components in radiotherapy and are examined for calibration, accuracy, and sensitivity. Dosimetric devices like ion chambers and diode detectors are vital for accurately measuring radiation doses. Two-dimensional dosimeters and film dosimeters, with their advantages and disadvantages, contribute to treatment plan verification and patient safety. While diamond detectors offer high precision, they come with higher production costs. Thermoluminescent dosimeters, using materials like LiF, provide accurate measurements and a wide dose range. MOSFET detectors, as semiconductor-based devices, respond quickly to radiation and are valuable for real-time dosimetry during treatment. Gel dosimetry, utilizing gel materials, offers high precision in measuring radiation doses but requires complex laboratory analysis.
In conclusion, the comprehensive quality control methods in radiotherapy are of vital importance for ensuring patient safety, treatment success, and the accurate operation of equipment. These controls, conducted in accordance with national and international protocols, adapt to evolving standards and technologies, contributing to the overall effectiveness and safety of the radiotherapy process.
Title: Current Developments in Radiotherapy Quality Control Methods
Description:
Quality control is of critical importance to ensure the accurate and reliable implementation of treatment in radiotherapy.
Radiotherapy is a primary method of treating diseases such as cancer, aiming to destroy cancer cells or control their growth using high-energy X-rays or gamma rays.
The quality control process encompasses a comprehensive series of procedures involving regular examination and evaluation of elements like radiotherapy devices, dosimetric components, and treatment planning systems.
The primary objectives of quality control are to enhance patient safety, ensure accurate dose delivery, and optimize treatment outcomes.
Due to its inclusion of critical parameters and safety measures, this process holds significant importance in the field of radiotherapy.
The quality control process begins with the examination of treatment devices and components.
Linear accelerators are the most commonly used devices in radiotherapy.
Quality control procedures for linear accelerators involve various steps, including reference dose measurement, dose output calibration, isocenter dose measurements, accuracy of irradiation, beam profile control, and dynamic field control.
The control of simulation and imaging devices such as CT simulation, MRI, PET/CT, and ultrasound plays a crucial role in radiotherapy preparation.
The quality control of these devices ensures the accuracy of elements such as calibration, visualization of anatomical structures, and assessment of image quality.
Ion chambers, diode detectors, two-dimensional dosimeters, diamond detectors, thermoluminescent dosimeters (TLD), Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET) detectors, and gel dosimeters are used for the control of devices and components in radiotherapy and are examined for calibration, accuracy, and sensitivity.
Dosimetric devices like ion chambers and diode detectors are vital for accurately measuring radiation doses.
Two-dimensional dosimeters and film dosimeters, with their advantages and disadvantages, contribute to treatment plan verification and patient safety.
While diamond detectors offer high precision, they come with higher production costs.
Thermoluminescent dosimeters, using materials like LiF, provide accurate measurements and a wide dose range.
MOSFET detectors, as semiconductor-based devices, respond quickly to radiation and are valuable for real-time dosimetry during treatment.
Gel dosimetry, utilizing gel materials, offers high precision in measuring radiation doses but requires complex laboratory analysis.
In conclusion, the comprehensive quality control methods in radiotherapy are of vital importance for ensuring patient safety, treatment success, and the accurate operation of equipment.
These controls, conducted in accordance with national and international protocols, adapt to evolving standards and technologies, contributing to the overall effectiveness and safety of the radiotherapy process.
Related Results
Radiotherapy refusal in breast cancer with breast-conserving surgery
Radiotherapy refusal in breast cancer with breast-conserving surgery
Abstract
Background
Although radiotherapy after breast-conserving surgery has been the standard treatment for breast cancer, some people still refus...
Carcinoma ex Pleomorphic Adenoma: A Case Series and Literature Review
Carcinoma ex Pleomorphic Adenoma: A Case Series and Literature Review
Abstract
Introduction
Carcinoma ex pleomorphic adenoma (CXPA) is a rare malignant salivary gland tumor that can lead to severe complications and carries a risk of distant metastasi...
The use of adjuvant radiotherapy in elderly patients with early‐stage breast cancer: Changes in practice patterns after publication of Cancer and Leukemia Group B 9343
The use of adjuvant radiotherapy in elderly patients with early‐stage breast cancer: Changes in practice patterns after publication of Cancer and Leukemia Group B 9343
BACKGROUNDThe Cancer and Leukemia Group B (CALGB) 9343 randomized phase 3 trial established lumpectomy and adjuvant therapy with tamoxifen alone, rather than both radiotherapy and ...
Radiotherapy in the Management of Gastrointestinal Stromal Tumors: A Systematic Review
Radiotherapy in the Management of Gastrointestinal Stromal Tumors: A Systematic Review
Gastrointestinal stromal tumors (GISTs) are considered insensitive to radiotherapy. However, a growing number of case reports and case series have shown that some lesions treated b...
Biological tumor markers associated with local control after primary radiotherapy in laryngeal cancer: A systematic review
Biological tumor markers associated with local control after primary radiotherapy in laryngeal cancer: A systematic review
AbstractBackgroundThe choice of treatment in laryngeal cancer is mainly based on tumor stage, post‐treatment morbidity and quality of life. Biological tumor markers might also be o...
Biopsy of palliative lesions following radiotherapy
Biopsy of palliative lesions following radiotherapy
Objective: Definite radiotherapy and/or chemoradiotherapy is often conducted for the treatment of non-small cell lung cancer. However, there is a potential concern regarding the mu...
Inhibitory effect of endostar combined with radiotherapy on gastric cancer animal models
Inhibitory effect of endostar combined with radiotherapy on gastric cancer animal models
Abstract
Background: Inhibitory effect of endostar combined with radiotherapy on gastric cancer (GC) animal models and its effect on transforming growth factor-β (TGF-β)1 a...
Radiotherapy Improves the Prognosis in Signet Ring Cell Carcinoma and Non-Signet Ring Cell Gastric Adenocarcinoma Patients: A SEER Database Analysis
Radiotherapy Improves the Prognosis in Signet Ring Cell Carcinoma and Non-Signet Ring Cell Gastric Adenocarcinoma Patients: A SEER Database Analysis
Objective: To investigate the effect of radiotherapy on prognosis in gastric signet ring cell carcinoma (SRCC) and gastric non-signet ring cell adenocarcinoma (NSRCC) patients. Me...