Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Initial Torque Stability of a New Bone Condensing Dental Implant. A Cohort Study of 140 Consecutively Placed Implants

View through CrossRef
Abstract The aim of this paper was to determine the torque resistance of this new implant during placement in different types of bone, immediate placement into sockets, and in grafted bone. The torque at time of placement serves as an indication of initial stability, which is accepted as an important factor for implant osseointegration and immediate loading. Within a 13-month period, 140 NobelActive implants in 84 consecutive patients were placed into types I–IV bone in fresh sockets, and into grafted bone (both in maxillary sinuses and on the facial alveolar surfaces where bone had been lost). The final torque was measured with a manual torque control wrench as manufactured by Nobel Biocare for clinical use with this type of implant. One hundred forty implants with 3.5 to 5 mm diameters and 10 to 15 mm lengths were placed in different types of bone, either as delayed or immediate implants into fresh extraction sockets. These implants demonstrated a mean torque stability value of 50.8 Ncm. The average insertion torque for delayed implants was 49.7 Ncm. For immediate implants the average torque was 52.6 Ncm. Placement into soft bone was also favorable at an average of 47.9 Ncm. Typical straight walled and tapered implants generally exhibit 10 to 35 Ncm insertion torques. The NobelActive implant consistently reaches higher torque levels. This may indicate they are more favorably suited to early provisionalization and loading. Soft bone (type IV) did not seem to decrease significantly the torque of insertion of these implants. Further longer term studies are needed to investigate whether this indeed makes these implants more suited for early provisionalization and loading than traditional root form. Long term studies are also needed to investigate maintenance of bone levels surrounding these implants.
American Academy of Implant Dentistry
Title: Initial Torque Stability of a New Bone Condensing Dental Implant. A Cohort Study of 140 Consecutively Placed Implants
Description:
Abstract The aim of this paper was to determine the torque resistance of this new implant during placement in different types of bone, immediate placement into sockets, and in grafted bone.
The torque at time of placement serves as an indication of initial stability, which is accepted as an important factor for implant osseointegration and immediate loading.
Within a 13-month period, 140 NobelActive implants in 84 consecutive patients were placed into types I–IV bone in fresh sockets, and into grafted bone (both in maxillary sinuses and on the facial alveolar surfaces where bone had been lost).
The final torque was measured with a manual torque control wrench as manufactured by Nobel Biocare for clinical use with this type of implant.
One hundred forty implants with 3.
5 to 5 mm diameters and 10 to 15 mm lengths were placed in different types of bone, either as delayed or immediate implants into fresh extraction sockets.
These implants demonstrated a mean torque stability value of 50.
8 Ncm.
The average insertion torque for delayed implants was 49.
7 Ncm.
For immediate implants the average torque was 52.
6 Ncm.
Placement into soft bone was also favorable at an average of 47.
9 Ncm.
Typical straight walled and tapered implants generally exhibit 10 to 35 Ncm insertion torques.
The NobelActive implant consistently reaches higher torque levels.
This may indicate they are more favorably suited to early provisionalization and loading.
Soft bone (type IV) did not seem to decrease significantly the torque of insertion of these implants.
Further longer term studies are needed to investigate whether this indeed makes these implants more suited for early provisionalization and loading than traditional root form.
Long term studies are also needed to investigate maintenance of bone levels surrounding these implants.

Related Results

Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
Impact of Dental and Zygomatic Implants on Stress Distribution in Maxillary Defects: A 3-Dimensional Finite Element Analysis Study
Impact of Dental and Zygomatic Implants on Stress Distribution in Maxillary Defects: A 3-Dimensional Finite Element Analysis Study
The aim of this study was to evaluate the stress distribution in the bone around dental and zygomatic implants for 4 different implant-supported obturator prostheses designs in a u...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 BMPs identified to da...
Influence of implant design, length, diameter, and anatomic region on implant stability: a randomized clinical trial
Influence of implant design, length, diameter, and anatomic region on implant stability: a randomized clinical trial
Objectives: To evaluate the influence of implant geometry and anatomical region on implant stability. Methods: A randomized controlled clinical trial was conducted on 45 patients, ...
AILING and FAILING Implants- A Review
AILING and FAILING Implants- A Review
Implants that show indications of problems but are not quite at the point of failure are referred to as failing implants. The long-term prognosis of the implant may be impacted by ...

Back to Top