SU‐E‐P‐44: The Characteristics and Clinical Application of the ArcCHECK for VMAT Verification
View through CrossRef
Purpose:To evaluate the characteristics and clinical suitability of the ArcCHECK QA system for VMAT verification.Methods:The intrinsic sensitivity,short and long term reproducibility,dose and dose rate dependence,dose per pulsed dependence,field sizes dependence and directional response of the diodes were measured.The results of the diodes were compared with the measurement results of an ionization chamber and calculated results of TPS. Gamma index (3mm distance to agreement and 3% percentage difference ) was used to analyze the dose difference between the calculation and measurement for random selected 211 verified VMAT plans.Results:The ArcCHECK diodes performed well for all tests except directional dependence, which varies from a minimum of −3.9% (seen only when the beam is incident on the diode at 180°) to a maximum of 7.7% (approximately at 255°). Average gamma analysis passing rates with 3mm/3% for 113 NPC,48 cervical cancer and 50 rectal cancer VMAT plans are 93.5%,95.7% and 97.5%, statistical significance has been found between either two of the groups(t=−12.69∼−4.88,all P<0.01).Conclusion:With proposed calibration method,the ArcCHECK QA system is very suitable for VMAT pretreatment verification,the complexity of VMAT plan is the main factor affecting the passing rate.
Title: SU‐E‐P‐44: The Characteristics and Clinical Application of the ArcCHECK for VMAT Verification
Description:
Purpose:To evaluate the characteristics and clinical suitability of the ArcCHECK QA system for VMAT verification.
Methods:The intrinsic sensitivity,short and long term reproducibility,dose and dose rate dependence,dose per pulsed dependence,field sizes dependence and directional response of the diodes were measured.
The results of the diodes were compared with the measurement results of an ionization chamber and calculated results of TPS.
Gamma index (3mm distance to agreement and 3% percentage difference ) was used to analyze the dose difference between the calculation and measurement for random selected 211 verified VMAT plans.
Results:The ArcCHECK diodes performed well for all tests except directional dependence, which varies from a minimum of −3.
9% (seen only when the beam is incident on the diode at 180°) to a maximum of 7.
7% (approximately at 255°).
Average gamma analysis passing rates with 3mm/3% for 113 NPC,48 cervical cancer and 50 rectal cancer VMAT plans are 93.
5%,95.
7% and 97.
5%, statistical significance has been found between either two of the groups(t=−12.
69∼−4.
88,all P<0.
01).
Conclusion:With proposed calibration method,the ArcCHECK QA system is very suitable for VMAT pretreatment verification,the complexity of VMAT plan is the main factor affecting the passing rate.
Related Results
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Objectives: This study aimed to find the optimal radiotherapy VMAT plans, that achieved high conformity and homogeneity to the planned target volume (PTV), and minimize the dose to...
Feasibility of 4D VMAT-CT
Feasibility of 4D VMAT-CT
Abstract
Objective. Feasibility of three-dimensional (3D) tracking of volumetric modulated arc therapy (VMAT) based on VMAT–computed tomography (V...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
Evaluation of Delta 4 system in patient specific QA for VMAT technique: Retrospective lung VMAT cases
Evaluation of Delta 4 system in patient specific QA for VMAT technique: Retrospective lung VMAT cases
Abstract
The objective of this study was to evaluate the Delta 4 system for lung VMAT technique. The standard fields and VMAT plans were generated into the homogeneo...
Feasibility of hypofractionated pelvic radiotherapy with parametrial and nodal simultaneous integrated boost for locally advanced cervical cancers: dummy run for the HYACINCT trial
Feasibility of hypofractionated pelvic radiotherapy with parametrial and nodal simultaneous integrated boost for locally advanced cervical cancers: dummy run for the HYACINCT trial
Objectives
The HYACINCT trial will investigate the role of dose-adapted hypofractionated pelvic radiotherapy in patients with locally advanced cervical cancer who are ineligible fo...
Shenzi 16-Inch Oil Export SCR CVA Verification
Shenzi 16-Inch Oil Export SCR CVA Verification
Abstract
In 2006 Enterprise developed a 16-inch oil export system from Shenzi field located in Green Canyon Block 653 in the Gulf of Mexico, approximately 120 nau...
Platform Verification - Aview From Amember Of Industry
Platform Verification - Aview From Amember Of Industry
ABSTRACT
Concerns have been raised in many sectors regarding the safety and reliability of offshore platforms. In this paper, the history of offshore operations a...