Javascript must be enabled to continue!
Evaluating the quality of electrical wires used for residential building wiring in Delta State, Nigeria
View through CrossRef
The utilization of counterfeit and substandard building materials for residential building construction had become a major concern, due to the hazards the occupants of those buildings are being subjected to. This research was carried out to appraise the quality of electrical wires used for residential building wiring in Delta State, Nigeria, and to also investigate the reasons why property developers still use these substandard materials despite the glaring negative consequences. Three commonly used electrical wire sizes (1.5, 2.5 and 4 mm2) for residential building electrical wiring were randomly selected within the Delta state, and their electrical properties (electrical resistance and electrical resistivity) and mechanical properties (area, tensile strength, and tensile strain) were determined following the Institute of Electrical and Electronics Engineers (IEEE 400), Nigeria Industrial Standard (NIS), and America Standard Testing Material (ASTM) International recommended procedures; also, well-structured questionnaires were administered to four groups of respondents. The findings indicated that the mechanical and electrical properties of most electrical wires, used for residential building wiring in Delta State failed to meet NIS standards. Across the five sampling locations, the mean electrical resistivity of the 1.5 mm2 wire ranged between 2.04±0.07x10-7 and 2.09±0.08x10-7 Ωmm, while the 2.5 mm2 wire's mean electrical resistivity varied from 1.90±0.06x10-7 to 1.97±0.13 x10-7 Ωmm, and the 4 mm2 wire’s mean electrical resistivity varied from 1.75±0.08 x10-7 to 1.87±0.06 x10-7 Ωmm. Also, across the five sampling locations, the mean tensile strength of the 1.5 mm2 wire ranged between 144.1 and 163.3 MPa, while the 2.5 mm2 wire's mean tensile strength varied from 163.2 to 177.4 MPa, and the 4 mm2 wire’s mean tensile strength varied from 169.4±20.6 to 185.4±17.2 MPa. Furthermore, the analysis of variance indicated that sampling location had no significant effect on the wires' mechanical and electrical properties (p≤0.05); portraying that this fraudulent practice is widespread across the state. The analysis of the questionnaire results confirmed that financial constraints and inappropriate actions of many building contractors were the major contributing factors to the utilization of substandard wires for residential building wiring in Nigeria. Based on this study's findings, it is recommended that standard regulatory agencies should step up their efforts against substandard building materials, to avoid its impending danger in Nigeria.
Integrity Mega Research Publishers
Title: Evaluating the quality of electrical wires used for residential building wiring in Delta State, Nigeria
Description:
The utilization of counterfeit and substandard building materials for residential building construction had become a major concern, due to the hazards the occupants of those buildings are being subjected to.
This research was carried out to appraise the quality of electrical wires used for residential building wiring in Delta State, Nigeria, and to also investigate the reasons why property developers still use these substandard materials despite the glaring negative consequences.
Three commonly used electrical wire sizes (1.
5, 2.
5 and 4 mm2) for residential building electrical wiring were randomly selected within the Delta state, and their electrical properties (electrical resistance and electrical resistivity) and mechanical properties (area, tensile strength, and tensile strain) were determined following the Institute of Electrical and Electronics Engineers (IEEE 400), Nigeria Industrial Standard (NIS), and America Standard Testing Material (ASTM) International recommended procedures; also, well-structured questionnaires were administered to four groups of respondents.
The findings indicated that the mechanical and electrical properties of most electrical wires, used for residential building wiring in Delta State failed to meet NIS standards.
Across the five sampling locations, the mean electrical resistivity of the 1.
5 mm2 wire ranged between 2.
04±0.
07x10-7 and 2.
09±0.
08x10-7 Ωmm, while the 2.
5 mm2 wire's mean electrical resistivity varied from 1.
90±0.
06x10-7 to 1.
97±0.
13 x10-7 Ωmm, and the 4 mm2 wire’s mean electrical resistivity varied from 1.
75±0.
08 x10-7 to 1.
87±0.
06 x10-7 Ωmm.
Also, across the five sampling locations, the mean tensile strength of the 1.
5 mm2 wire ranged between 144.
1 and 163.
3 MPa, while the 2.
5 mm2 wire's mean tensile strength varied from 163.
2 to 177.
4 MPa, and the 4 mm2 wire’s mean tensile strength varied from 169.
4±20.
6 to 185.
4±17.
2 MPa.
Furthermore, the analysis of variance indicated that sampling location had no significant effect on the wires' mechanical and electrical properties (p≤0.
05); portraying that this fraudulent practice is widespread across the state.
The analysis of the questionnaire results confirmed that financial constraints and inappropriate actions of many building contractors were the major contributing factors to the utilization of substandard wires for residential building wiring in Nigeria.
Based on this study's findings, it is recommended that standard regulatory agencies should step up their efforts against substandard building materials, to avoid its impending danger in Nigeria.
Related Results
De gevel – een intermediair element tussen buiten en binnen
De gevel – een intermediair element tussen buiten en binnen
This study is based on the fact that all people have a basic need for protection from other people (and animals) as well as from the elements (the exterior climate). People need a ...
Delta-8-THC: Delta-9-THC’s nicer younger sibling?
Delta-8-THC: Delta-9-THC’s nicer younger sibling?
Abstract
Background
Products containing delta-8-THC became widely available in most of the USA following the 2018 Farm Bill and by late 2020 were co...
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
<span style="font-size: 11pt; color: black; font-family: 'Times New Roman','serif'">ΠΗΛΙΝΑ ΙΓ&Delta...
Management of displaced transverse fractures of the patella using tension band wiring with or without circumferential cerclage wiring: A comparative study
Management of displaced transverse fractures of the patella using tension band wiring with or without circumferential cerclage wiring: A comparative study
Background: Transverse fractures of body of the patella are by far the most common fractures of this bone. Surgical fixation is the recommended treatment in displaced fractures wit...
Damping Performance of Glass Fiber Reinforced Polymers With Embedded Shape Memory Alloy Wires
Damping Performance of Glass Fiber Reinforced Polymers With Embedded Shape Memory Alloy Wires
Abstract
This paper explores the integration of shape memory alloy (SMA) wires within fiber reinforced polymer (FRP) composites to enhance their dynamic properties. ...
Demographic characteristics of SARS-CoV-2 B.1.617.2 (Delta) variant infections in Indian population
Demographic characteristics of SARS-CoV-2 B.1.617.2 (Delta) variant infections in Indian population
Abstract
Importance
Higher risks of contracting infection, developing severe illness and mortality are known facts in aged and ...
COMPARATIVE STUDY OF TENSION BAND WIRING, MODIFIED TENSION BAND WIRING AND FULLY THREADED CANNULATED CANCELLOUS SCREWS FOR FIXATION OF MEDIAL MALLEOLUS FRACTURES
COMPARATIVE STUDY OF TENSION BAND WIRING, MODIFIED TENSION BAND WIRING AND FULLY THREADED CANNULATED CANCELLOUS SCREWS FOR FIXATION OF MEDIAL MALLEOLUS FRACTURES
Objective: To compare the three most commonly used fixation techniques: “Tension band wiring, modified tension band wiring, and fully threaded cannulated cancellous screws for fixa...
Prophylactic wiring vs. non-wiring in hip arthroplasty: finite element and cadaveric analysis of proximal femur biomechanics
Prophylactic wiring vs. non-wiring in hip arthroplasty: finite element and cadaveric analysis of proximal femur biomechanics
Abstract
Background
Intraoperative periprosthetic femur fracture is a serious complication in hip arthroplasty, affecting patient outcomes. This ...

