Variability in surveillance practice for patients with diagnosis of bicuspid aortic valve syndrome
View through CrossRef
Background/Aim: In patients with bicuspid aortic valves, guidelines call
for regular follow-up to monitor disease progression and guide timely
intervention. We aimed to evaluate how closely these recommendations are
followed at a tertiary care center. Methods: This was retrospective
cohort study at a tertiary care center. Among 48,504 patients who
received echocardiograms between 2013-2018, 245 patients were identified
to have bicuspid aortic valve. Bivariate analyses compared patient and
echocardiographic characteristics between patients who did and did not
receive follow-up by a cardiovascular specialist. Results: The mean age
of the cohort was 55.2 15.6 years and 30.2% were female. During a
median follow-up of 3.5 2.2 years, 72.7% of patients had at least one
visit with a cardiovascular specialist after diagnosis of bicuspid
aortic valve by echocardiogram. Patients followed by specialists had a
higher proportion of follow-up surveillance by echocardiogram (78.7%
vs. 34.3%, p< .0001), or by CT or MRI (41.0% vs. 3.0%, p
< .0001), and were more likely to undergo valve or aortic
surgery compared with patients not followed by specialists. Patients
with moderate to severe valvular or aortic pathology (aortic
stenosis/regurgitation, dilated ascending aorta) were not more likely to
be followed by a cardiovascular specialist or receive follow-up
echocardiograms. Conclusions: Follow-up care for patients with bicuspid
aortic valve was highly variable, and surveillance imaging was performed
sparsely despite guidelines. There is an urgent need for surveillance
and clinical follow-up mechanisms to monitor this patient population
with increased risk of progressive valvulopathy and aortopathy.
Title: Variability in surveillance practice for patients with diagnosis of bicuspid aortic valve syndrome
Description:
Background/Aim: In patients with bicuspid aortic valves, guidelines call
for regular follow-up to monitor disease progression and guide timely
intervention.
We aimed to evaluate how closely these recommendations are
followed at a tertiary care center.
Methods: This was retrospective
cohort study at a tertiary care center.
Among 48,504 patients who
received echocardiograms between 2013-2018, 245 patients were identified
to have bicuspid aortic valve.
Bivariate analyses compared patient and
echocardiographic characteristics between patients who did and did not
receive follow-up by a cardiovascular specialist.
Results: The mean age
of the cohort was 55.
2 15.
6 years and 30.
2% were female.
During a
median follow-up of 3.
5 2.
2 years, 72.
7% of patients had at least one
visit with a cardiovascular specialist after diagnosis of bicuspid
aortic valve by echocardiogram.
Patients followed by specialists had a
higher proportion of follow-up surveillance by echocardiogram (78.
7%
vs.
34.
3%, p< .
0001), or by CT or MRI (41.
0% vs.
3.
0%, p
< .
0001), and were more likely to undergo valve or aortic
surgery compared with patients not followed by specialists.
Patients
with moderate to severe valvular or aortic pathology (aortic
stenosis/regurgitation, dilated ascending aorta) were not more likely to
be followed by a cardiovascular specialist or receive follow-up
echocardiograms.
Conclusions: Follow-up care for patients with bicuspid
aortic valve was highly variable, and surveillance imaging was performed
sparsely despite guidelines.
There is an urgent need for surveillance
and clinical follow-up mechanisms to monitor this patient population
with increased risk of progressive valvulopathy and aortopathy.
Related Results
Techniques of Aortic Valve Repair
Techniques of Aortic Valve Repair
Similar to mitral repair, newer methods of aortic valve reconstruction are achieving excellent outcomes with an 85% to 90% freedom from valve-related complications at 10 years. The...
P1816Aortic root morphology in bicuspid aortic valve is related to the type of BAV
P1816Aortic root morphology in bicuspid aortic valve is related to the type of BAV
Abstract
Background
Dilatation of the ascending aorta associated with bicuspid aortic valve (BAV) is common and has been associa...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve Pathology: Current Evidence and Technical Challenges
Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve Pathology: Current Evidence and Technical Challenges
Transcatheter aortic valve implantation (TAVI) is an established therapy for severe symptomatic aortic valve stenosis (AS) in patients at high and intermediate risk for surgical ao...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Variability in surveillance practice for patients with diagnosis of bicuspid aortic valve syndrome
Variability in surveillance practice for patients with diagnosis of bicuspid aortic valve syndrome
AbstractIn patients with bicuspid aortic valves, guidelines call for regular follow-up to monitor disease progression and guide intervention. We aimed to evaluate how closely these...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can
occur in patients with prior conotruncal defect surgery, the Ross
procedure, and connective tissue disease (CTD). Val...
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Objective: To compare the heart valve circumference before and after 10% formalin fixation. Materials and Methods: The study analyzed 63 Thai human cadaveric hearts. Each heart val...