Indoor Climates and Energy Consumption by Air Conditioning System in a Learning Resource Centre in Malaysia

View through CrossRef
A Learning Resource Centre is a type of library that houses books and all other media facilities as well as daily newspapers and journal articles. Indoor climates such as the indoor dry bulb temperature and relative humidity must be controlled at the recommended level in a Learning Resource Centre in order to keep the collections and archival materials in good condition. Based on the ASEAN Energy Organization report, 50-60% of the total energy consumption of a building goes to Heating, Ventilating and Air Conditioning (HVAC) systems operation. As such, energy savings for HVAC systems is crucial and should be studied, especially after climate change has taken place. In this paper, the author installed data loggers in the Resource Centre for a period of a month to monitor the indoor climate changing trend. Due to the lack of cooling and dehumidification processes when the HVAC systems were turned off, there were peaks in both indoor dry bulb temperature and relative humidity during the night. The ambient high relative humidity had caused an increase in the indoor relative humidity at night. At the same time, the energy consumption simulation of the HVAC systems was run using the Transient Energy System Simulation Tool (TRNSYS). Different operating modes were set in the simulations to obtain the comparison of energy consumption for the different operating modes of the HVAC systems under four different weather elements, namely the present-day, 2020’s, 2050’s and 2080’s time scenarios. Electricity bills for the different scenarios based on current electricity tariffs were analyzed. The results show that a significant saving can be obtained if the HVAC systems were operated under the All-day Operating Mode.
Title: Indoor Climates and Energy Consumption by Air Conditioning System in a Learning Resource Centre in Malaysia
Description:
A Learning Resource Centre is a type of library that houses books and all other media facilities as well as daily newspapers and journal articles.
Indoor climates such as the indoor dry bulb temperature and relative humidity must be controlled at the recommended level in a Learning Resource Centre in order to keep the collections and archival materials in good condition.
Based on the ASEAN Energy Organization report, 50-60% of the total energy consumption of a building goes to Heating, Ventilating and Air Conditioning (HVAC) systems operation.
As such, energy savings for HVAC systems is crucial and should be studied, especially after climate change has taken place.
In this paper, the author installed data loggers in the Resource Centre for a period of a month to monitor the indoor climate changing trend.
Due to the lack of cooling and dehumidification processes when the HVAC systems were turned off, there were peaks in both indoor dry bulb temperature and relative humidity during the night.
The ambient high relative humidity had caused an increase in the indoor relative humidity at night.
At the same time, the energy consumption simulation of the HVAC systems was run using the Transient Energy System Simulation Tool (TRNSYS).
Different operating modes were set in the simulations to obtain the comparison of energy consumption for the different operating modes of the HVAC systems under four different weather elements, namely the present-day, 2020’s, 2050’s and 2080’s time scenarios.
Electricity bills for the different scenarios based on current electricity tariffs were analyzed.
The results show that a significant saving can be obtained if the HVAC systems were operated under the All-day Operating Mode.

Related Results

Energy efficient ventilation strategies for surgery rooms
Energy efficient ventilation strategies for surgery rooms
Surgery rooms are a space type with particularly stringent indoor environmental quality (IEQ) requirements, which translate into high energy use. Due to the unclear IEQ and infecti...
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Abstract It is important to know whether SARS-CoV-2 is spread through the air-conditioning systems. Taking the central air-conditioning system as an example, we analyze the...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
The elderly residing in nursing homes are typically more advanced in age, have more health issues, and spend more time indoors than other elderly people. This study explored the in...
Dwelling on Courtyards
Dwelling on Courtyards
The urban heat island (UHI) phenomenon and the dependency of buildings on
fossil fuels were the two main issues that formed this dissertation. UHI results in higher air temperature...
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
ABSTRACTOn a global and regional scale, Indonesia has one of the least environmentally sustainable economies in the Asia-Pacific region. Consumption is one of the key factors contr...
Indoor and outdoor air quality relationships modelling
Indoor and outdoor air quality relationships modelling
Particulate matter (PM) related ambient pollution has emerged as one of the most significant environmental and human health issues during the last decades. Thus, ambient PM concent...
Editorial
Editorial
CHIEF EDITOR Ahmad Faris Ismail, IIUM, Malaysia TECHNICAL EDITOR Sany Izan Ihsan, IIUM, Malaysia EXECUTIVE EDITOR AHM Zahirul Alam, IIUM, Malaysia ASSOCIATE EDITO...

Back to Top