Hydrophobic Initiator Activates the Interface Reaction to Trigger Polymerization Graft Polytetrafluoroethylene Catheter
View through CrossRef
Decreasing the surface friction coefficient of medical catheters is important especially in interventional treatment, but the current solution involves high cost or cumbersome manufacturing processes. In order to effectively solve the problem of high friction coefficient of the inner and outer layers in the use of medical catheters and simplify the manufacturing process, we use polytetrafluoroethylene (PTFE) as a catheter material to graft directly with PAAm hydrogel. In order to overcome the high chemical inertness and low surface energy of PTFE, nitrogen ion injection is used to modify the surface of PTFE. The resulting porous PTFE surface is loaded with initiators and the hydrogel monomers polymerize in situ to form a lubricating layer. The hydrogel coating is strongly bonding on PTFE substrate, the maximum 180° peel strength between PAAm hydrogel and PTFE substrate reaches at 222 N/m. The hydrogel lubricating layer provide a friction coefficient of 0.04. In addition, in comparison to silicone rubber, the surface biofilm adhesion is diminished by 350%, demonstrating exceptional anti-fouling characteristics. This study provides a new idea and method for the surface low friction design of implantable medical devices.
Warwick Evans Publishing
Title: Hydrophobic Initiator Activates the Interface Reaction to Trigger Polymerization Graft Polytetrafluoroethylene Catheter
Description:
Decreasing the surface friction coefficient of medical catheters is important especially in interventional treatment, but the current solution involves high cost or cumbersome manufacturing processes.
In order to effectively solve the problem of high friction coefficient of the inner and outer layers in the use of medical catheters and simplify the manufacturing process, we use polytetrafluoroethylene (PTFE) as a catheter material to graft directly with PAAm hydrogel.
In order to overcome the high chemical inertness and low surface energy of PTFE, nitrogen ion injection is used to modify the surface of PTFE.
The resulting porous PTFE surface is loaded with initiators and the hydrogel monomers polymerize in situ to form a lubricating layer.
The hydrogel coating is strongly bonding on PTFE substrate, the maximum 180° peel strength between PAAm hydrogel and PTFE substrate reaches at 222 N/m.
The hydrogel lubricating layer provide a friction coefficient of 0.
04.
In addition, in comparison to silicone rubber, the surface biofilm adhesion is diminished by 350%, demonstrating exceptional anti-fouling characteristics.
This study provides a new idea and method for the surface low friction design of implantable medical devices.
Related Results
Synthesis and kinetic studies of TiO2/polystyrene composite particles by emulsion polymerization
Synthesis and kinetic studies of TiO2/polystyrene composite particles by emulsion polymerization
AbstractIn the presence of titanium dioxide (TiO2) nanoparticles, emulsion polymerization of styrene with sodium dodecyl sulphate (SDS) as an emulsifier and potassium persulphate a...
Peripherally Inserted Central Catheters in Children: A Prospective Single-Center Analysis of Associated Complications
Peripherally Inserted Central Catheters in Children: A Prospective Single-Center Analysis of Associated Complications
Highlights
Overall, 72% (n = 63) of PICCs remained in situ until intended therapy was completed.
In 24...
Preparation of hyperbranched polymers by atom transfer radical polymerization
Preparation of hyperbranched polymers by atom transfer radical polymerization
AbstractA cheap acrylic AB* monomer, 2‐(2‐chloroacetyloxy)‐isopropyl acrylate (CAIPA), was prepared from 2‐hydroxyisopropyl acrylate with chloroacetyl chloride in the presence of t...
Polymerization in Living Organisms for Biomedical Applications
Polymerization in Living Organisms for Biomedical Applications
AbstractIntra‐tissue polymerization as a kind of polymerization reaction in biological tissues has the advantages of good biocompatibility, accurate localization, and dynamic respo...
Knowledge and Practice of Catheter-related urinary tract infection prevention and Associated factor among nurses in public hospitals, West Shoa, Oromia, Ethiopia
Knowledge and Practice of Catheter-related urinary tract infection prevention and Associated factor among nurses in public hospitals, West Shoa, Oromia, Ethiopia
Abstract
Background
Catheter-related urinary tract infection is an infection related to imported pathogens, which affects the urinary tract of patients with a urinary cath...
A STUDY ON THE USE OF DIFFERENT MATERIALS COMBINED WITH ALLOGRAFT ON OSSEOINTEGRATION AND BONE REGENERATION OF DENTAL IMPLANTS WITH CORONAL DEFECTS IN A RABBIT MODEL
A STUDY ON THE USE OF DIFFERENT MATERIALS COMBINED WITH ALLOGRAFT ON OSSEOINTEGRATION AND BONE REGENERATION OF DENTAL IMPLANTS WITH CORONAL DEFECTS IN A RABBIT MODEL
Objectives: To assess differential effects of different materials combined with allograft on bone-to-implant contact and newly formed bone formation in dental implants with coronal...
Doxorubicin-Immersed Skeletal Muscle Grafts Promote Peripheral Nerve Regeneration Across a 10-mm Defect in the Rat Sciatic Nerve
Doxorubicin-Immersed Skeletal Muscle Grafts Promote Peripheral Nerve Regeneration Across a 10-mm Defect in the Rat Sciatic Nerve
Background The treatment of peripheral nerve defects requires bridging materials. Skeletal muscle grafts have been studied as an alternative to nerve autografts because they contai...
Study on two different dithiobenzoates effectiveness in bulk RAFT polymerization of β-myrcene.
Study on two different dithiobenzoates effectiveness in bulk RAFT polymerization of β-myrcene.
Abstract
The study aimed to evaluate the impact of two chain transfer controllers, ethyl 2-(phenylcarbonothiolthio)-2-phenylacetate (EPPA) and 2-(4-methoxyphenylcarbonothio...