Research on key parameters of water mist fire protection in ship cabin
View through CrossRef
Abstract
Because of good cooling, heat absorption, attenuation of heat radiation and other functions, water mist is especially suitable for ship fire extinguishing and cooling. The CFD software is used to simulate water mist fire extinguishing and cooling in a ship cabin under the condition of six different parameter combinations. When the grain size is less than 150μm, the cabin temperature can be reduced to 25°C in three minutes after water mist intervention. The larger the flow rate, the smaller the grain size, the faster the cooling rate. Fire extinguishing efficiency test of water mist in small scale ship cabin is carried out. The result shows that water mist with grain size of 100μm-150μm can quickly extinguish fire and reduce cabin temperature to 25°C in two minutes.
Title: Research on key parameters of water mist fire protection in ship cabin
Description:
Abstract
Because of good cooling, heat absorption, attenuation of heat radiation and other functions, water mist is especially suitable for ship fire extinguishing and cooling.
The CFD software is used to simulate water mist fire extinguishing and cooling in a ship cabin under the condition of six different parameter combinations.
When the grain size is less than 150μm, the cabin temperature can be reduced to 25°C in three minutes after water mist intervention.
The larger the flow rate, the smaller the grain size, the faster the cooling rate.
Fire extinguishing efficiency test of water mist in small scale ship cabin is carried out.
The result shows that water mist with grain size of 100μm-150μm can quickly extinguish fire and reduce cabin temperature to 25°C in two minutes.
Related Results
Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle
Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle
A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process...
Effect of Cold Plasma Treatment on Microbial Load and Quality of Baby Carrots
Effect of Cold Plasma Treatment on Microbial Load and Quality of Baby Carrots
In the United States, about 80 percent of all food shipments and 91 percent of all temperature controlled freight shipments, including about 28.5 million tons of refrigerated fruit...
Connecting Ship Operation and Architecture in Ship Design Processes
Connecting Ship Operation and Architecture in Ship Design Processes
It is challenging to deal with the operation of ships by crew members in ship design processes. This is important because the efficiency and safety of ship operations ultimately de...
Efficacy and safety of surfactant administration by MIST and INSURE techniques in Neonates with Respiratory Distress Syndrome: A randomized controlled trial
Efficacy and safety of surfactant administration by MIST and INSURE techniques in Neonates with Respiratory Distress Syndrome: A randomized controlled trial
Objective: To measure the efficacy and safety of surfactant administered by MIST and INSURE to neonates with respiratory distress syndrome.
Methods: A randomized controlled t...
An Estimation Method of Fire Extinguishing Time in Closed Ship Cabin
An Estimation Method of Fire Extinguishing Time in Closed Ship Cabin
There are many potential fire hazards in ship engine cabin, especially in the closed environment of submarine underwater. Fires in cramped cabin are usually harder to put out, ther...
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Abstract Purpose: The invention relates to the oil industry, inorganic chemistry, in particular, to the methods of complex processing of formation water, using flare gas of oil and...
Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist
Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist
The objective of this work is to investigate the diesel analog pool fire with water mist .For this purpose, a series of water mist fire suppression experiment are carried out by ch...
Experimental Study on Cooling a Hot Solid Surface with Water Mist
Experimental Study on Cooling a Hot Solid Surface with Water Mist
In this paper, a series of experiments are performed to investigate the hot solid surface cooling with water mist under different conditions, such as different initial surface temp...