Javascript must be enabled to continue!
Double-Needle Yamane Repositioning of a Previous Yamane Fixation
View through CrossRef
We describe a case of anteriorly dislocated, Yamane-fixated secondary intraocular lens (IOLs) with pigmentary dispersion syndrome. The patient presented with significant visual impairment and elevated intraocular pressure despite being maximally treated with all topical antihypertensive medications. The iris-IOL touch was confirmed by ultrasound biomicroscopy, and fundus examination revealed evidence of pigment granules on the optic disc. The previous Yamane-fixated secondary IOL was repositioned using a double-needle adaptation of Yamane technique and Kim’s modification of scleral-fixated IOLs. To our knowledge, this is the first ever documented case of double-needle Yamane technique of a previous Yamane-fixated eye. In cases of inadequate capsular support, the development of new surgical techniques for the fixation of IOL continues to improve the safety and efficacy of these complicated surgeries.
Title: Double-Needle Yamane Repositioning of a Previous Yamane Fixation
Description:
We describe a case of anteriorly dislocated, Yamane-fixated secondary intraocular lens (IOLs) with pigmentary dispersion syndrome.
The patient presented with significant visual impairment and elevated intraocular pressure despite being maximally treated with all topical antihypertensive medications.
The iris-IOL touch was confirmed by ultrasound biomicroscopy, and fundus examination revealed evidence of pigment granules on the optic disc.
The previous Yamane-fixated secondary IOL was repositioned using a double-needle adaptation of Yamane technique and Kim’s modification of scleral-fixated IOLs.
To our knowledge, this is the first ever documented case of double-needle Yamane technique of a previous Yamane-fixated eye.
In cases of inadequate capsular support, the development of new surgical techniques for the fixation of IOL continues to improve the safety and efficacy of these complicated surgeries.
Related Results
Needle consideration in umbilical two-port laparoscopic percutaneous extraperitoneal closure for patent processus vaginalis of children: hook-needle or forcep-needle
Needle consideration in umbilical two-port laparoscopic percutaneous extraperitoneal closure for patent processus vaginalis of children: hook-needle or forcep-needle
Abstract
Background
Although umbilical two-port laparoscopic percutaneous extraperitoneal closure for the treatment of processus vaginalis patency o...
Design and Experimental Evaluation of Mosquito-Inspired Needle Structure in Soft Materials
Design and Experimental Evaluation of Mosquito-Inspired Needle Structure in Soft Materials
Abstract
Insects steer their stingers effortlessly to a specific target and release their venom in a certain path through the skin with minimal pain. These unique tr...
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Background:
Primarily ligamentous Lisfranc injuries occur in athletic populations. Unstable Lisfranc injuries are treated with internal fixation or arthrodesis. Interna...
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
ABSTRACT
Introduction
Syndesmotic injuries present a challenge to orthopedic surgeons. Malreduction of the syndesmosis has been reported to cause instability and secondary osteoar...
Genome-wide fixation under viability selection
Genome-wide fixation under viability selection
AbstractWe investigate through simulations the effect of random sweepstakes, recurrent bottlenecks, dominance, and epistasis on selection a diploid population when the phenotype is...
Needle with a Novel Attachment versus Conventional Screw-Thread Needles: A Preference and Ease-of-Use Test among Children and Adolescents with Diabetes
Needle with a Novel Attachment versus Conventional Screw-Thread Needles: A Preference and Ease-of-Use Test among Children and Adolescents with Diabetes
Background: This usability test investigated the overall preference and usability of the novel NovoTwist® insulin pen needle versus conventional screw-thread needles, when used wit...
A Clinical Comparison between Single-Space Technique and Double-Space Technique for Combined Spinal and Epidural Anesthesia
A Clinical Comparison between Single-Space Technique and Double-Space Technique for Combined Spinal and Epidural Anesthesia
Background:
Combined spinal and epidural anesthesia (CSEA) is commonly performed by double space technique (DST) and single space segment technique (SST) or needle-thro...
Comparison of Two Modified Sutureless Techniques of Scleral Fixation of Intraocular Lens
Comparison of Two Modified Sutureless Techniques of Scleral Fixation of Intraocular Lens
BACKGROUND AND OBJECTIVE:
To compare the visual outcome and complications of two different sutureless scleral-fixated intraocular lens (IOL) implantation techniques, th...

