Javascript must be enabled to continue!
GW24-e1771 Clinical studies of predicting response to cardiac resynchronisation therapy
View through CrossRef
Objectives
To establish a score system derived from clinical, echocardiographic and electrocardiographic factors and evaluate its clinical value for cardiac resynchronisation therapy (CRT) patient selection.
Methods
A total of 90 patients receiving CRT (60.8 ± 12.9 years) were enrolled. All patients underwent standard EKG and echocardiography evaluation before implantation and during follow-up. The parameters measured by EKG were: duration of QRS, morphology of QRS. Left ventricular end-systolic and end-diastolic dimensions (LVESD, LVEDD), end-systolic and end-diastolic volumes (LVESV, LVEDV), left ventricular ejection fraction (LVEF), interventricular mechanical delay (IVMD), tricuspid annular plane systolic excursion (TAPSE), degree of mitral and tricuspid regurgitation and pulmonary artery pressure (PAH) were calculated by echocardiography. Global longitudinal (LS), circumferential (CS) and radial strain (RS) values were analysed based on speckle tracking imaging. We measured standard deviation of time to reach minimum regional volume of 16 segments (systolic dyssynchrony index, SDI) related to the heart cycle from real-time three-dimensional echocardiography. A patient selection score system was generated by the clinical, echocardiographic and electrocardiographic parameters achieving a significance level by univariate and multivariate regression model. The Wald test was used to evaluate te weight of the variables to predict CRT response. A positive response to CRT was a LVESV decrease of ≥15% and not reaching primary clinical endpoint (death or rehospitalisation for heart failure) at the end of follow-up.
Results
Thirty-seven patients were CRT non-responders (41.11%) and 53 were responder (58.89%). A 4-point score system was generated based on TAPSE ≥ 14.8mm, SDI ≥ 12.62%, LS ≤ -7.22% and QRSd ≥ 171 ms. The sensitivity and specificity for prediction a positive response to CRT at a score ≥3 were 0.792 and 0.946, respectively (AUC: 0.945, 95% CI: 0.902-0.988, p < 0.001)
Conclusions
A patient selection score system based on the integration of TAPSE, SDI, LS and QRSd can help to predict positive response to CRT effectively and reliably.
Title: GW24-e1771 Clinical studies of predicting response to cardiac resynchronisation therapy
Description:
Objectives
To establish a score system derived from clinical, echocardiographic and electrocardiographic factors and evaluate its clinical value for cardiac resynchronisation therapy (CRT) patient selection.
Methods
A total of 90 patients receiving CRT (60.
8 ± 12.
9 years) were enrolled.
All patients underwent standard EKG and echocardiography evaluation before implantation and during follow-up.
The parameters measured by EKG were: duration of QRS, morphology of QRS.
Left ventricular end-systolic and end-diastolic dimensions (LVESD, LVEDD), end-systolic and end-diastolic volumes (LVESV, LVEDV), left ventricular ejection fraction (LVEF), interventricular mechanical delay (IVMD), tricuspid annular plane systolic excursion (TAPSE), degree of mitral and tricuspid regurgitation and pulmonary artery pressure (PAH) were calculated by echocardiography.
Global longitudinal (LS), circumferential (CS) and radial strain (RS) values were analysed based on speckle tracking imaging.
We measured standard deviation of time to reach minimum regional volume of 16 segments (systolic dyssynchrony index, SDI) related to the heart cycle from real-time three-dimensional echocardiography.
A patient selection score system was generated by the clinical, echocardiographic and electrocardiographic parameters achieving a significance level by univariate and multivariate regression model.
The Wald test was used to evaluate te weight of the variables to predict CRT response.
A positive response to CRT was a LVESV decrease of ≥15% and not reaching primary clinical endpoint (death or rehospitalisation for heart failure) at the end of follow-up.
Results
Thirty-seven patients were CRT non-responders (41.
11%) and 53 were responder (58.
89%).
A 4-point score system was generated based on TAPSE ≥ 14.
8mm, SDI ≥ 12.
62%, LS ≤ -7.
22% and QRSd ≥ 171 ms.
The sensitivity and specificity for prediction a positive response to CRT at a score ≥3 were 0.
792 and 0.
946, respectively (AUC: 0.
945, 95% CI: 0.
902-0.
988, p < 0.
001)
Conclusions
A patient selection score system based on the integration of TAPSE, SDI, LS and QRSd can help to predict positive response to CRT effectively and reliably.
Related Results
RESYNCHRONISATION THERAPY IN PATIENTS WITH CHRONIC HEART FAILURE (10 CASES REPORTED PLUS)
RESYNCHRONISATION THERAPY IN PATIENTS WITH CHRONIC HEART FAILURE (10 CASES REPORTED PLUS)
Objectives
To evaluate the clinical effect of cardiac resynchronisation therapy on systolic function in patients with New York Heart Association class III or IV c...
Mediator kinase submodule-dependent regulation of cardiac transcription
Mediator kinase submodule-dependent regulation of cardiac transcription
<p>Pathological cardiac remodeling results from myocardial stresses including pressure and volume overload, neurohumoral activation, myocardial infarction, and hypothyroidism...
The Impact of IL28B Gene Polymorphisms on Drug Responses
The Impact of IL28B Gene Polymorphisms on Drug Responses
To achieve high therapeutic efficacy in the patient, information on pharmacokinetics, pharmacodynamics, and pharmacogenetics is required. With the development of science and techno...
Predictive value of left atrial remodeling for response to cardiac
resynchronization therapy
Predictive value of left atrial remodeling for response to cardiac
resynchronization therapy
Aim: Response to cardiac resynchronization therapy varies significantly among
patients, with one third of them failing to demonstrate left ventricular reverse
...
CARDIAC RESYNCHRONISATION THERAPY EFFECTS COMPARE OF THE SURGERY EPICARDIAL LEAD VERSUS CORONARY SINUS LEAD PLACEMENT
CARDIAC RESYNCHRONISATION THERAPY EFFECTS COMPARE OF THE SURGERY EPICARDIAL LEAD VERSUS CORONARY SINUS LEAD PLACEMENT
Objectives
Cardiac resynchronisation therapy (CRT) with biventricular pacing has demonstrated cardiac function improvement. Two strategies (coronary sinus vs epic...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
GW24-e1129 The analysis of cardiac resynchronisation therapy in right ventricular pacing patients
GW24-e1129 The analysis of cardiac resynchronisation therapy in right ventricular pacing patients
Objectives
Acording an investigaion of 417 Grade A hospitals in China of recent 10 years, pacemaker implantation has been raising at an average of 11% per year. O...