Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

DESIGN CHARACTERISTICS OF THE HORIZONTAL STEAM GENERATOR PGV-1000

View through CrossRef
The materials of the article consider the design characteristics of horizontal steam generators PGV-1000 for WWER NPPs. The NPP steam generator, in particular the PGV-1000 steam generator, is a specific heat exchange unit. This unit, together with a nuclear reactor and a steam turbine, is one of the main equipment of multi-circuit (double-circuit) steam turbine NPPs. The steam generator produces working steam using heat dissipated from the reactor core by the cooling medium and sent to the heat exchange surface of the steam generator. NPP steam generators, connecting the contours of the coolant and the working substance, equally belong to each of them. The heat-absorbing medium in the steam generator is the working substance (water, steam). PGV-1000 type NPP steam generators with pressurized water reactors produce dry saturated steam. The requirement to maintain high purity of the coolant is due to the heat transfer surfaces of such steam generators made of austenitic stainless steel with electropolished surfaces. WWER reactors do not allow the coolant to boil in the core, so the temperature of the coolant at the outlet of the reactor (at the inlet to the steam generator) is always lower than the saturation temperature corresponding to the water pressure in the coolant circuit. Underheating of the coolant to the saturation temperature (approximately 25 ÷ 30 °С) guarantees the exclusion of vaporization even in the most loaded reactor channels. The design characteristics of modern horizontal steam generators such as PGV-1000 of various modifications provide high technical and economic performance of NPP units with WWER-1000 and high maintainability, which allows to extend the service life of domestic NPPs.
Title: DESIGN CHARACTERISTICS OF THE HORIZONTAL STEAM GENERATOR PGV-1000
Description:
The materials of the article consider the design characteristics of horizontal steam generators PGV-1000 for WWER NPPs.
The NPP steam generator, in particular the PGV-1000 steam generator, is a specific heat exchange unit.
This unit, together with a nuclear reactor and a steam turbine, is one of the main equipment of multi-circuit (double-circuit) steam turbine NPPs.
The steam generator produces working steam using heat dissipated from the reactor core by the cooling medium and sent to the heat exchange surface of the steam generator.
NPP steam generators, connecting the contours of the coolant and the working substance, equally belong to each of them.
The heat-absorbing medium in the steam generator is the working substance (water, steam).
PGV-1000 type NPP steam generators with pressurized water reactors produce dry saturated steam.
The requirement to maintain high purity of the coolant is due to the heat transfer surfaces of such steam generators made of austenitic stainless steel with electropolished surfaces.
WWER reactors do not allow the coolant to boil in the core, so the temperature of the coolant at the outlet of the reactor (at the inlet to the steam generator) is always lower than the saturation temperature corresponding to the water pressure in the coolant circuit.
Underheating of the coolant to the saturation temperature (approximately 25 ÷ 30 °С) guarantees the exclusion of vaporization even in the most loaded reactor channels.
The design characteristics of modern horizontal steam generators such as PGV-1000 of various modifications provide high technical and economic performance of NPP units with WWER-1000 and high maintainability, which allows to extend the service life of domestic NPPs.

Related Results

The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
The Hot Test of Primary Separation Equipment of Steam Generator for CAP1400 Nuclear Power Plant
A new type of Steam separator for CAP1400 Steam Generator is introduced. The result of characteristic experiment, the variables of which contain steam load, saturated water flow an...
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
TINBOP Cyclic Steam Injection Enhances Oil Recovery in Mature Steamfloods
Abstract In a previous paper (SPE/PS-CIM/CHOA 97850), we presented our findings on a novel cyclic steam injection method that we developed. The Top-Injection Bott...
STUDI ANALISIS EFISIENSI STEAM TURBINE GENERATOR PADA BAGIAN ASAM SULFAT DAN UTILITAS DEPARTEMEN PRODUKSI IIIB PT PETROKIMIA GRESIK
STUDI ANALISIS EFISIENSI STEAM TURBINE GENERATOR PADA BAGIAN ASAM SULFAT DAN UTILITAS DEPARTEMEN PRODUKSI IIIB PT PETROKIMIA GRESIK
Sejumlah energi penggerak peralatan proses sangat diperlukan dalam proses produksi di seluruh pabrik yang ada pada PT Petrokimia Gresik. Departemen Produksi IIIB memiliki unit util...
Steam-CO Recovery Processes For Bottom Water Oil Reservoirs
Steam-CO Recovery Processes For Bottom Water Oil Reservoirs
Abstract Based on Pujol and Boberg's scaling criteria, a series of experiments on steam-CO2 injection strategies was conducted in a high temperature, high pressur...
Pressure Transient Analysis in SAGD
Pressure Transient Analysis in SAGD
Abstract Steam-Assisted Gravity Drainage (SAGD) is an in-situ thermal recovery technique used at Petro-Canada's MacKay River Project. SAGD utilizes pairs of horiz...
Single Horizontal Well in Thermal Recovery Processes
Single Horizontal Well in Thermal Recovery Processes
Abstract Horizontal wells have been used in conjunction with thermal enhanced recovery for several years now, and various well configurations have been applied. I...
Steam-Powered Offshore Oil Producing Platforms
Steam-Powered Offshore Oil Producing Platforms
1. ABSTRACT This paper will briefly describe the parallel development of an oil production platform topsides with a conventional gas turbine driver system. This w...
A Reservoir Assessment of The Geysers Geothermal Field
A Reservoir Assessment of The Geysers Geothermal Field
Summary Big Sulphur Creek fault zone may be part of a deep-seated, wrench-style fault system through which hydrothermal fluids from deeper horizons rise to relati...

Back to Top