Javascript must be enabled to continue!
Multidetector Pulsed-Neutron Tool Application in Low-Porosity Reservoir–A Case Study in Mutiara Field, Indonesia
View through CrossRef
In mature fields, pulsed-neutron logging is commonly used to solve for the remaining saturation behind the casing. For years, sigma-based saturation has been used to calculate gas saturation behind casing; however, the high dependency of sigma-to-water salinity of the formation, especially the low-dynamic range at porosity near 12 p.u., has proven to be challenging in low-porosity gas rock. A new measurement from the third detector from a multidetector pulsed-neutron tool (MDPNT) is proposed to provide a better estimation of the gas saturation in a low-porosity reservoir. Two sets of independently measured sigma and the third detector were taken in a casedhole well, with a dual-tubing system of a long string and short string. For the third-detector measurement, the measurement was based on the ratio of the slow capture gate and inelastic gate component from the decay curve created by the long detector. This ratio can be used to detect gas in a tight reservoir with a minimum salinity and lithology effect. This data will then be used to calculate the gas saturation from the third detector, and the result is compared to sigma-based gas saturation. At an interval where the porosity is above 12 p.u., the sigma-based gas saturation and MDPNT-based gas saturation are very much in agreement. However, in a low-porosity reservoir near 12 p.u. or below, the sigma-based measurement starts to show its limitation. Meanwhile, the MDPNT-based gas saturation clearly shows the remaining gas saturation where sigma-based measurements failed to detect it. The subsequent decision was made based on the log analysis result, and perforation was done at a potential interval based on the MDPNT result. The results from the production test confirm the MDPNT-based gas saturation with 700-Mscf/d gas production added. This study showcases a new technology to solve a low-porosity gas reservoir issue where a sigma-based measurement underestimates the remaining gas saturation. Using two different measurements in the same well, the results from the MDPNT measurement demonstrated a better result compared to the sigma-based measurement in low-porosity rock
Society of Petrophysicists and Well Log Analysts (SPWLA)
Title: Multidetector Pulsed-Neutron Tool Application in Low-Porosity Reservoir–A Case Study in Mutiara Field, Indonesia
Description:
In mature fields, pulsed-neutron logging is commonly used to solve for the remaining saturation behind the casing.
For years, sigma-based saturation has been used to calculate gas saturation behind casing; however, the high dependency of sigma-to-water salinity of the formation, especially the low-dynamic range at porosity near 12 p.
u.
, has proven to be challenging in low-porosity gas rock.
A new measurement from the third detector from a multidetector pulsed-neutron tool (MDPNT) is proposed to provide a better estimation of the gas saturation in a low-porosity reservoir.
Two sets of independently measured sigma and the third detector were taken in a casedhole well, with a dual-tubing system of a long string and short string.
For the third-detector measurement, the measurement was based on the ratio of the slow capture gate and inelastic gate component from the decay curve created by the long detector.
This ratio can be used to detect gas in a tight reservoir with a minimum salinity and lithology effect.
This data will then be used to calculate the gas saturation from the third detector, and the result is compared to sigma-based gas saturation.
At an interval where the porosity is above 12 p.
u.
, the sigma-based gas saturation and MDPNT-based gas saturation are very much in agreement.
However, in a low-porosity reservoir near 12 p.
u.
or below, the sigma-based measurement starts to show its limitation.
Meanwhile, the MDPNT-based gas saturation clearly shows the remaining gas saturation where sigma-based measurements failed to detect it.
The subsequent decision was made based on the log analysis result, and perforation was done at a potential interval based on the MDPNT result.
The results from the production test confirm the MDPNT-based gas saturation with 700-Mscf/d gas production added.
This study showcases a new technology to solve a low-porosity gas reservoir issue where a sigma-based measurement underestimates the remaining gas saturation.
Using two different measurements in the same well, the results from the MDPNT measurement demonstrated a better result compared to the sigma-based measurement in low-porosity rock.
Related Results
Comparative study of the effect of neutrons emitted from neutron source 241Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source 241Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
AbstractIntroductionCancer is one of the major medical problems threatening human health. Breast cancer is the most prevalent type of cancer in women. Reports indicate that treatme...
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
Unconventional reservoirs have low porosity and complex mineral composition containing quartz, feldspar, calcite, dolomite, pyrite and kerogen, which may seriously reduce the accur...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
CAN A NEW DOUBLE PARTICLE DETECTOR-CLYC (CS2LIYCL6:CE) BE USED IN PN LOGGING FOR TIGHT GAS EVALUATION?
CAN A NEW DOUBLE PARTICLE DETECTOR-CLYC (CS2LIYCL6:CE) BE USED IN PN LOGGING FOR TIGHT GAS EVALUATION?
Unconventional oil and gas resources, such as tight oil and gas, have become indispensably succeeding energy sources in nowadays. At the stage of exploration, gas saturation is ess...
Development and Baseline Comparison of a New Pulsed-Neutron Spectroscopy Tool for Carbon- Oxygen Analysis and Three-Phase Saturation Monitoring
Development and Baseline Comparison of a New Pulsed-Neutron Spectroscopy Tool for Carbon- Oxygen Analysis and Three-Phase Saturation Monitoring
A new multidetector pulsed-neutron logging tool is introduced. Pulsed-neutron capture (PNC) and carbon/oxygen (C/O) measurements from pulsed-neutron logging tools are used as part ...
The Methods Taken in SZ36-1 Oilfield in the Early Stage of Production
The Methods Taken in SZ36-1 Oilfield in the Early Stage of Production
Abstract
SZ 36-1 Oil Field is located in Liaodong Bay of Bohai Sea and is an unconsolidated sand and structure-lithology reservoir. The reservoir is distributed i...
The Effect of Formation Absorption on the Thermal Neutron Porosity Measurement
The Effect of Formation Absorption on the Thermal Neutron Porosity Measurement
Abstract
Compensated thermal neutron porosity devices provide reliable estimates of formation porosity in standard borehole conditions. Departure from these conditio...

