Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Measurement Technique for the Absolute Acoustic Nonlinearity Parameter Employing Only a Narrowband Pulser

View through CrossRef
In the nonlinear ultrasonic technique, the measurement of the absolute acoustic nonlinearity parameter is employed to obtain quantitative material nonlinearity. In the piezoelectric method, this measurement involves two processes: calibration and harmonic measurements. In the calibration process, a transfer function is obtained, and distortion of the propagating wave is measured in the harmonic measurement. In the conventional method for this measurement, a narrowband pulser is typically used for the harmonic measurement, while a broadband pulser is used for the calibration measurement. In this study, we propose a technique that utilizes a narrowband pulser for both harmonic and calibration measurements. First, we introduced the proposed method to measure the transfer function in the calibration measurement employing the narrowband pulser. Then, we compared the results of the transfer functions and the absolute acoustic nonlinearity parameters obtained using both a narrowband and broadband pulser in the calibration. Based on the experimental results, we found that the results obtained using both the proposed and conventional methods are highly similar, confirming the validity of the proposed measurement technique. In conclusion, even though we exclusively employ the narrowband pulser, we can accurately measure the absolute nonlinearity parameter, leading to a reduction in the required measurement equipment.
Title: Measurement Technique for the Absolute Acoustic Nonlinearity Parameter Employing Only a Narrowband Pulser
Description:
In the nonlinear ultrasonic technique, the measurement of the absolute acoustic nonlinearity parameter is employed to obtain quantitative material nonlinearity.
In the piezoelectric method, this measurement involves two processes: calibration and harmonic measurements.
In the calibration process, a transfer function is obtained, and distortion of the propagating wave is measured in the harmonic measurement.
In the conventional method for this measurement, a narrowband pulser is typically used for the harmonic measurement, while a broadband pulser is used for the calibration measurement.
In this study, we propose a technique that utilizes a narrowband pulser for both harmonic and calibration measurements.
First, we introduced the proposed method to measure the transfer function in the calibration measurement employing the narrowband pulser.
Then, we compared the results of the transfer functions and the absolute acoustic nonlinearity parameters obtained using both a narrowband and broadband pulser in the calibration.
Based on the experimental results, we found that the results obtained using both the proposed and conventional methods are highly similar, confirming the validity of the proposed measurement technique.
In conclusion, even though we exclusively employ the narrowband pulser, we can accurately measure the absolute nonlinearity parameter, leading to a reduction in the required measurement equipment.

Related Results

Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Intense sound exposure that exceeds the pain threshold of human auditory sensitivity, known as acoustic trauma, causes significant and extensive changes in the auditory system. Thr...
Applications Of Acoustic Image Logs
Applications Of Acoustic Image Logs
Abstract Acoustic image logs have been acquired in the Barua/Motatan and Mara fields as a part of the information acquisition program implemented by Maraven, S.A....
On the Flow-Excited Acoustic Resonance of Isolated Cylinder(s) in Cross-Flow
On the Flow-Excited Acoustic Resonance of Isolated Cylinder(s) in Cross-Flow
The flow-excited acoustic resonance of single and multiple cylinders in cross-flow is investigated experimentally. The effect of the cylinder(s) proximity to the acoustic particle ...
Pengembangan Parameter Penilaian Keamanan Pelayanan Kesehatan Tradisional Empiris
Pengembangan Parameter Penilaian Keamanan Pelayanan Kesehatan Tradisional Empiris
Abstract        In the context of protecting the community against the security of traditional empirical health services, more detailed safety assessment parameters have been dev...
Optical-Acoustic Mode Coupling in a Hierarchical Nonlinear Acoustic Metamaterial
Optical-Acoustic Mode Coupling in a Hierarchical Nonlinear Acoustic Metamaterial
Locally resonant nonlinear acoustic metamaterials can provide low-frequency control and bandwidth extension, but many designs are narrow-band, have limited tunability and robustnes...
Acoustic cloaking design based on penetration manipulation with combination acoustic metamaterials
Acoustic cloaking design based on penetration manipulation with combination acoustic metamaterials
The acoustic wave transmission manipulation ability is the most important performance for the acoustic metamaterials. To manipulate the acoustic transmission, the combination acous...
Recognition of fish acoustic patterns at monitoring of freshwater ecosystems
Recognition of fish acoustic patterns at monitoring of freshwater ecosystems
The basic sources of contamination and obstruction of reservoirs are cleared not enough sewer water of industrial and communal enterprises, large stock-raising complexes, wastes of...

Back to Top