Computational Analysis of a Lecture Room Ventilation System
View through CrossRef
The level of Indoor Air Quality (IAQ) has become a big topic of research, and improving it using passive ventilation methods is imperative due to the cost saving potentials. Designing lecture buildings to use less energy or Zero Energy (ZE) has become more important, and analysing buildings before construction can save money in design changes. This research analyses the performance (thermal comfort [TC]) of a lecture room, investigate the use of passive ventilation methods and determine the energy-saving potential of the proposed passive ventilation method using Computational Fluid Dynamics (CFD). Results obtained showed that air change per hour at a wind velocity of 0.05 m/s was 3.10, which was below standards. Therefore, the lecture hall needs external passive ventilation systems (Solar Chimney [SC]) for improved indoor air quality at minimum cost. Also, it was observed that the proposed passive ventilation (SC) system with the size between 1 and 100 m3, made an improvement upon the natural ventilation in the room. There was a 66.69% increase after 10 years in the saving of energy and cost using Solar Chimney as compared to Fans, which depicts that truly energy and cost were saved using passive ventilation systems rather than mechanical ventilation systems.
IntechOpen
Title: Computational Analysis of a Lecture Room Ventilation System
Description:
The level of Indoor Air Quality (IAQ) has become a big topic of research, and improving it using passive ventilation methods is imperative due to the cost saving potentials.
Designing lecture buildings to use less energy or Zero Energy (ZE) has become more important, and analysing buildings before construction can save money in design changes.
This research analyses the performance (thermal comfort [TC]) of a lecture room, investigate the use of passive ventilation methods and determine the energy-saving potential of the proposed passive ventilation method using Computational Fluid Dynamics (CFD).
Results obtained showed that air change per hour at a wind velocity of 0.
05 m/s was 3.
10, which was below standards.
Therefore, the lecture hall needs external passive ventilation systems (Solar Chimney [SC]) for improved indoor air quality at minimum cost.
Also, it was observed that the proposed passive ventilation (SC) system with the size between 1 and 100 m3, made an improvement upon the natural ventilation in the room.
There was a 66.
69% increase after 10 years in the saving of energy and cost using Solar Chimney as compared to Fans, which depicts that truly energy and cost were saved using passive ventilation systems rather than mechanical ventilation systems.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Ventilation in university classrooms during the COVID-19 pandemic
Ventilation in university classrooms during the COVID-19 pandemic
The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus has caused a pandemic, forcing schools and universities to stop in-person classes. For universities to allow ...
Episodic ventilation lowers the efficiency of pulmonary CO2excretion
Episodic ventilation lowers the efficiency of pulmonary CO2excretion
The ventilation pattern of many ectothermic vertebrates, as well as hibernating and diving endotherms, is episodic where breaths are clustered in bouts interspersed among apneas of...
CT-based ventilation imaging in radiation oncology
CT-based ventilation imaging in radiation oncology
A form of lung function imaging is emerging that uses phase-resolved four-dimensional CT (4DCT or breath-hold CT) images along with image processing techniques to generate lung fun...
Study of ventilated low-slope and large span wooden element roofs in the current and future climate
Study of ventilated low-slope and large span wooden element roofs in the current and future climate
Finland's building regulations and guidelines rely on ventilation to ensure the hygrothermal performance of structures. For wooden roofs, height of ventilation cavity and area of v...
High frequency percussive ventilation: An asset to existing ventilation modi in intraoperative care?
High frequency percussive ventilation: An asset to existing ventilation modi in intraoperative care?
High frequency percussive ventilation (HFPV) is a ventilation mode that combines positive pressure ventilation with some advantages of high frequency ventilation. During HFPV, a pu...
Immersive simulation approach in designing the first prone position ventilation course for trauma critical care and emergency medicine cases
Immersive simulation approach in designing the first prone position ventilation course for trauma critical care and emergency medicine cases
Background: The prone ventilation technique has been newly adopted by HMC (Hamad Medical Corporation). The literature has revealed the effectiveness of the prone position technique...
Comparison of cardiopulmonary resuscitation that applied synchronous 30 compressions–2 ventilations with that applied asynchronous 110/min compression–10/min ventilation: A mannequin study
Comparison of cardiopulmonary resuscitation that applied synchronous 30 compressions–2 ventilations with that applied asynchronous 110/min compression–10/min ventilation: A mannequin study
Background:CPR model of a resuscitation to be ventilated with a bag valve mask constitutes a discussion when evaluated with the current guidance.Objective:This study aims to compar...