Patch test results in 542 patients with suspected contact dermatitis in Turkey

View through CrossRef
In this retrospective study, patch test results of 542 patients (303 female and 239 male), referred to our clinic between June 1996 and July 1999, were evaluated. All patients were patch tested with 32 allergens of an extended European standard series, 140 patients were tested with supplemental series, and 246 patients with their own substances. 280 (51.7%) patients had 1 or more positive results but allergic contact dermatitis, according to clinical relevance, was diagnosed in only 190 (67.9%) of these. Nickel sulfate was the most frequent sensitizer (19.1%), followed by potassium dichromate (11.8%), palladium chloride (9.4%), cobalt chloride (8.5%), and thiuram mix (7.7%). Frequencies of contact allergy to fragrance mix (5.5%), balsam of Peru (Myroxylon Pereirae resin) (2%), quaternium‐15 (0.6%), and Kathon CG (methylchloroisothiazolinone+methylisothiazolinone) (0.2%) were relatively low, while no positive reactions were obtained to paraben mix in any case. Current clinical relevance to the present dermatitis was most frequently seen with carba mix (96.2%), thiuram mix (95.2%) and potassium dichromate (78.1%), whereas this rate was low for nickel (37.5%). In 85.8% of patients with allergic contact dermatitis, the responsible allergen was detected by testing with the extended standard series alone (18.4% identified by testing with the additional 10 allergens), in 11.6% by testing with the patients' own substances, and in 2.6% by testing with the supplemental series. Occupational contact dermatitis was diagnosed in 77 of the patients with positive reactions (27.5%), most of these being construction workers and house painters who showed relevant sensitizations to potassium dichromate, cobalt chloride, thiuram mix and carba mix. There was no statistically significant difference in the total contact sensitization rate between atopics and non‐atopics, but contact sensitivity to nickel sulfate and palladium chloride was significantly higher among atopics. MOAHL index in % was: 44.1/14.2/24.9/ 54.4/2.4. In conclusion, we believe that similar large series of patients would be helpful to delineate the exact profile of contact dermatitis in Turkey.
Title: Patch test results in 542 patients with suspected contact dermatitis in Turkey
Description:
In this retrospective study, patch test results of 542 patients (303 female and 239 male), referred to our clinic between June 1996 and July 1999, were evaluated.
All patients were patch tested with 32 allergens of an extended European standard series, 140 patients were tested with supplemental series, and 246 patients with their own substances.
280 (51.
7%) patients had 1 or more positive results but allergic contact dermatitis, according to clinical relevance, was diagnosed in only 190 (67.
9%) of these.
Nickel sulfate was the most frequent sensitizer (19.
1%), followed by potassium dichromate (11.
8%), palladium chloride (9.
4%), cobalt chloride (8.
5%), and thiuram mix (7.
7%).
Frequencies of contact allergy to fragrance mix (5.
5%), balsam of Peru (Myroxylon Pereirae resin) (2%), quaternium‐15 (0.
6%), and Kathon CG (methylchloroisothiazolinone+methylisothiazolinone) (0.
2%) were relatively low, while no positive reactions were obtained to paraben mix in any case.
Current clinical relevance to the present dermatitis was most frequently seen with carba mix (96.
2%), thiuram mix (95.
2%) and potassium dichromate (78.
1%), whereas this rate was low for nickel (37.
5%).
In 85.
8% of patients with allergic contact dermatitis, the responsible allergen was detected by testing with the extended standard series alone (18.
4% identified by testing with the additional 10 allergens), in 11.
6% by testing with the patients' own substances, and in 2.
6% by testing with the supplemental series.
Occupational contact dermatitis was diagnosed in 77 of the patients with positive reactions (27.
5%), most of these being construction workers and house painters who showed relevant sensitizations to potassium dichromate, cobalt chloride, thiuram mix and carba mix.
There was no statistically significant difference in the total contact sensitization rate between atopics and non‐atopics, but contact sensitivity to nickel sulfate and palladium chloride was significantly higher among atopics.
MOAHL index in % was: 44.
1/14.
2/24.
9/ 54.
4/2.
4.
In conclusion, we believe that similar large series of patients would be helpful to delineate the exact profile of contact dermatitis in Turkey.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Chest Wall Hydatid Cysts: A Systematic Review
Chest Wall Hydatid Cysts: A Systematic Review
Abstract Introduction Given the rarity of chest wall hydatid disease, information on this condition is primarily drawn from case reports. Hence, this study systematically reviews t...
Using Patch Testing to Improve Therapeutic Outcome in the Treatment of Hand Eczema in Vietnamese Patients
Using Patch Testing to Improve Therapeutic Outcome in the Treatment of Hand Eczema in Vietnamese Patients
BACKGROUND: Hand eczema is a common chronic and relapsing skin disease with various clinical features. Hand eczema aetiology can be allergic contact dermatitis (ACD), irritant cont...
Studi Literatur: Faktor Risiko Dermatitis Kontak pada Pekerja
Studi Literatur: Faktor Risiko Dermatitis Kontak pada Pekerja
Abstract. Contact dermatitis is inflammation of the skin caused by contact with exogenous substances characterized by itching, redness, scaling, vesicles and papules. Trigger facto...
Principais sensibilizantes em pacientes idosos e não idosos com dermatite de contato
Principais sensibilizantes em pacientes idosos e não idosos com dermatite de contato
Aims: To evaluate the prevalence of the main allergens found in allergic contact dermatitis among elderly and non-elderly patients.Methods: Retrospective study of the medical recor...
Refining intra-patch connectivity measures in landscape fragmentation and connectivity indices
Refining intra-patch connectivity measures in landscape fragmentation and connectivity indices
Abstract Context. Measuring intra-patch connectivity, i.e. the connectivity within a habitat patch, is important to evaluate landscape fragmentation and connectivity. Howev...
Reducing Computational Complexity in Vision Transformers Using Patch Slimming
Reducing Computational Complexity in Vision Transformers Using Patch Slimming
Vision Transformers (ViTs) have emerged as a dominant class of deep learning models for image recognition tasks, demonstrating superior performance compared to traditional Convolut...
Characteristics of Contact Dermatitis Patients (Irritant and Allergic) in RSUD Batara Siang Pangkep District
Characteristics of Contact Dermatitis Patients (Irritant and Allergic) in RSUD Batara Siang Pangkep District
Introduction: Contact dermatitis is the occurrence of an inflammation of the skin caused by exposure to a toxin (primary irritant) or by an allergenic material (sensitizer) or by b...

Back to Top