Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Potentiometric Membrane Sensors for Levamisole Determination

View through CrossRef
The ion pair (IP) of levamisole with BiI4 - (SbI4 - ) for the levamisole-selective sensor with a PVC membrane containing - ions were developed. Thermal behavior of obtained IP was investigated by differential thermal analysis that would show the thermal stability and the character of the decomposition of the complex. The thermolysis of Lev+BiI4 - IP undergoes three stages that fit a theoretical interpretation. The linearity ranges of levamisole sensors function are 7.9 ×10-6 – 1×10-1 (7.9 ×10-5 – 1×10-1 ) M. The Nernstian slope of 50.6 – 53.4 mV pC−1 and detection limit of 5.0 × 10−5 – 1.5 × 10−4) M. The working range of pH is 2.8 – 6.0. The efficiency of the use of electrodes for levamisole content control in pharmaceutical preparations was shown by direct potentiometry and potentiometric titration methods.
Title: Potentiometric Membrane Sensors for Levamisole Determination
Description:
The ion pair (IP) of levamisole with BiI4 - (SbI4 - ) for the levamisole-selective sensor with a PVC membrane containing - ions were developed.
Thermal behavior of obtained IP was investigated by differential thermal analysis that would show the thermal stability and the character of the decomposition of the complex.
The thermolysis of Lev+BiI4 - IP undergoes three stages that fit a theoretical interpretation.
The linearity ranges of levamisole sensors function are 7.
9 ×10-6 – 1×10-1 (7.
9 ×10-5 – 1×10-1 ) M.
The Nernstian slope of 50.
6 – 53.
4 mV pC−1 and detection limit of 5.
0 × 10−5 – 1.
5 × 10−4) M.
The working range of pH is 2.
8 – 6.
The efficiency of the use of electrodes for levamisole content control in pharmaceutical preparations was shown by direct potentiometry and potentiometric titration methods.

Related Results

Levamisole Toxicity
Levamisole Toxicity
To the Editor: Levamisole use will no doubt increase following the recent report by Laurie et al and the National Cancer Institute (NCI) Clinical Alert both related to the use of ...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Development of Microcontroller Based Potentiometric Transduction Circuit for a Continuous Fluid Level Sensor
Development of Microcontroller Based Potentiometric Transduction Circuit for a Continuous Fluid Level Sensor
This paper presents the development of microcontroller based potentiometric transduction circuit for a continuous fluid level sensor. The purpose system involved the integration be...
Effects of levamisole on haematological and oxidative stress parameters in packed donkeys
Effects of levamisole on haematological and oxidative stress parameters in packed donkeys
Abstract Stress can be caused by psychological, physiological, environmental and physical factors. Strenuous exercise like packing in donkeys modifies haematologic paramete...
Potentiometric sensors
Potentiometric sensors
This chapter describes the functioning of potentiometric sensors, how they can be usefully employed, and in which experimental situations. Potentiometric sensors work through the m...
Proton Polymer Electrolytes in Fuel Cell
Proton Polymer Electrolytes in Fuel Cell
The electrolyte is one of the main parts of a fuel cell. That is divided into liquid and solid and it is used in both Alkaline and acidulous PH. But with due to kind of electrolyte...

Back to Top