Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution

View through CrossRef
ABSTRACTA popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT) which enables multiplexed proteome analyses. Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer. However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements. This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments. It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth. Here we defined the lower boundaries for resolving TMT reporter ions with 0.0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer. We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold. Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified, but with a slight loss in quantification precision and accuracy. These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments relying on TMT reporter ion quantification with identical integer masses.
Title: Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
Description:
ABSTRACTA popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT) which enables multiplexed proteome analyses.
Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer.
However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements.
This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments.
It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth.
Here we defined the lower boundaries for resolving TMT reporter ions with 0.
0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer.
We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold.
Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified, but with a slight loss in quantification precision and accuracy.
These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments relying on TMT reporter ion quantification with identical integer masses.

Related Results

Sparsity‐enhanced wavelet deconvolution
Sparsity‐enhanced wavelet deconvolution
ABSTRACTWe propose a three‐step bandwidth enhancing wavelet deconvolution process, combining linear inverse filtering and non‐linear reflectivity construction based on a sparseness...
Mass spectrometry of oligosaccharides
Mass spectrometry of oligosaccharides
Abstract I. Introduction 162  II. CHARACTERISTICS OF TANDEM MASS SPECTRA OF CARBOHYDRATES 163 A.  Ionization of Carbohydrates 163     1.  Electrospray Ionization (E...
Wave Scattering Deconvolution
Wave Scattering Deconvolution
ABSTRACT The least-squares approach is commonly used for spiking and predictive deconvolution. An alternative approach is wave scattering deconvolution (WSD) prop...
Template E-commerce Dinda Wulandari 16011106
Template E-commerce Dinda Wulandari 16011106
1.Tag untuk menentukan tipe dokumen2.Tag ini digunakan untuk membuat Background belakang dari website3.Tag untuk membuat sebuah dokumen HTML4.Tag untuk membuat judul dari sebuah ha...
Encoder Hurwitz Integers: The Hurwitz integers that have the ”division with small division” property
Encoder Hurwitz Integers: The Hurwitz integers that have the ”division with small division” property
Abstract The residue class set of a Hurwitz integer is constructed by modulo function with primitive Hurwitz integer whose norm is a prime integer, i.e. prime Hurwitz integ...
TRANSTORNO DE ANSIEDADE GENERALIZADA (TAG): AVALIÇÃO DAS ABORDAGENS TERAPÊUTICAS ATUAIS E PERSPECTIVAS DE INTERVENÇÃO
TRANSTORNO DE ANSIEDADE GENERALIZADA (TAG): AVALIÇÃO DAS ABORDAGENS TERAPÊUTICAS ATUAIS E PERSPECTIVAS DE INTERVENÇÃO
Introdução O Transtorno de Ansiedade Generalizada (TAG) é uma condição psicológica caracterizada por uma preocupação excessiva e persistente com diversas áreas da vida, mesmo na au...
NLTD 2.0: A Nonlinear Framework for Robust and Customizable Color Deconvolution in Histopathology
NLTD 2.0: A Nonlinear Framework for Robust and Customizable Color Deconvolution in Histopathology
Abstract Advancements in computational approaches have enabled robust utilization of histological tissue data. A crucial step in the development of computational tools ...
Abstract 1554: Development of a deconvolution algorithm for tissue-based gene expression data
Abstract 1554: Development of a deconvolution algorithm for tissue-based gene expression data
Abstract Tissue data provide substantially more information than cell-line data, and offer new opportunities to study cancer biology and evolution in its actual micr...

Back to Top