Ultraviolet Imaging Techniques for Off-Line Condition Monitoring of Power System Equipment

View through CrossRef
By using appropriate method to detect the functioning state of electrical equipment is always significantly more concerned with operational and economic point of view. With invention of the instruments which can capture images at Ultraviolet and infrared wavelength gives the required information for perceiving condition of the particular power system equipment with contactless measurement of parameters which leads the system to abnormal condition. Thermal, Corona images are those of such kind will be useful for the offline monitoring of the complex power system equipment where human cannot go and observe the actual status while system is under energized state. The equipment’s mainly Power transformer, insulators, Circuit breakers, transmission line connection of power system are to be examined correctly. Thermal Imaging mainly gives the temperature raise of the component of the equipment and from that data is useful in analyzing the reasons and process for scheduled preservation before the disorder of the system. The corona discharge will cause the waste of power energy, radio interference, audible noise, insulation aging, and these defects are great threats to the safety and stability of electrical equipment. The different corona discharge defect part of high voltage electrical equipment is Listed such as the grading ring, drop wire, jumper and over line, spacing rods, tube bus end and connecting joint. While the photon numbers of corona discharge under different defects are measured by the ultraviolet imager called as corona image. The analysis is conducted for a 33KV/11KV primary substation of a Distribution system along with secondary transmission line for thermal and Corona imaging. Infra-red Thermal camera and Ultraviolet Corona camera are used for the taking images at the substation. Thus, obtained data is compared with respective international standards for taking appropriate schedule for maintenance or clearance of the effected equipment at the earliest time possible to get the consumer with uninterruptable power supply.
Title: Ultraviolet Imaging Techniques for Off-Line Condition Monitoring of Power System Equipment
Description:
By using appropriate method to detect the functioning state of electrical equipment is always significantly more concerned with operational and economic point of view.
With invention of the instruments which can capture images at Ultraviolet and infrared wavelength gives the required information for perceiving condition of the particular power system equipment with contactless measurement of parameters which leads the system to abnormal condition.
Thermal, Corona images are those of such kind will be useful for the offline monitoring of the complex power system equipment where human cannot go and observe the actual status while system is under energized state.
The equipment’s mainly Power transformer, insulators, Circuit breakers, transmission line connection of power system are to be examined correctly.
Thermal Imaging mainly gives the temperature raise of the component of the equipment and from that data is useful in analyzing the reasons and process for scheduled preservation before the disorder of the system.
The corona discharge will cause the waste of power energy, radio interference, audible noise, insulation aging, and these defects are great threats to the safety and stability of electrical equipment.
The different corona discharge defect part of high voltage electrical equipment is Listed such as the grading ring, drop wire, jumper and over line, spacing rods, tube bus end and connecting joint.
While the photon numbers of corona discharge under different defects are measured by the ultraviolet imager called as corona image.
The analysis is conducted for a 33KV/11KV primary substation of a Distribution system along with secondary transmission line for thermal and Corona imaging.
Infra-red Thermal camera and Ultraviolet Corona camera are used for the taking images at the substation.
Thus, obtained data is compared with respective international standards for taking appropriate schedule for maintenance or clearance of the effected equipment at the earliest time possible to get the consumer with uninterruptable power supply.

Related Results

Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Kajian Efek Radiasi Ultraviolet terhadap Kulit
Kajian Efek Radiasi Ultraviolet terhadap Kulit
Abstract. Ultraviolet (UV) radiation consists of UV A, UV B, and UV C rays which are distinguished by their wavelength. Exposure to high-intensity ultraviolet light can cause side ...
Exploration of intelligent monitoring technology for the operation status of large port loading and unloading machinery equipment
Exploration of intelligent monitoring technology for the operation status of large port loading and unloading machinery equipment
This article takes the large-scale loading and unloading machinery equipment and intelligent monitoring technology in ports as the research This article takes the large-scale loadi...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
DESAIN SISTEM MONITORING KUALITAS DAYA LISTRIK SECARA ONLINE
DESAIN SISTEM MONITORING KUALITAS DAYA LISTRIK SECARA ONLINE
Abstract Electrical power delivered by the utility to the consumer have a good quality when the value of the voltage and frequency in accordance with applicable regula...
[RETRACTED] Keto Max Power - BURN FATINSTEAD OF CARBS with Keto Max Power! v1
[RETRACTED] Keto Max Power - BURN FATINSTEAD OF CARBS with Keto Max Power! v1
[RETRACTED]Keto Max Power Reviews: Warning! Don’t Buy Dragons Den Pills Fast Until You Read This UK Latest Report Weight gain’s principle of “energy intake exceeding energy spent”...

Back to Top