Investigation of radon level in air and tap water of workplaces at Thailand Institute of Nuclear Technology, Thailand

View through CrossRef
Abstract Thailand Institute of Nuclear Technology (TINT) has continuously monitored radiation exposure and radionuclide in workplaces specifically radon gas to estimate effective dose for workers. Radon exposure is the second leading cause of lung cancer in the world. In this study, radon in air and tap water at building no. 3, 7, 8, 9 and 18 on Ongkharak site of TINT have been measured for 5 years from 2012 to 2016. Radon level in air and tap water were investigated on 83 stations (workplaces) and 54 samples, respectively. Radon concentrations in air and tap water were measured by using the pulsed ionization chamber (ATMOS 12 DPX). Indoor radon concentrations in air were in the range of 12-138 Bq.m-3 with an average value of 30.13±17.05 Bq.m-3. Radon concentrations in tap water were in the range of 0.10 to 2.89 Bq.l-1 with an average value of 0.51±0.55 Bq.l-1. The results of radon concentrations at TINT were below the US Environmental Protection Agency (US EPA) safety limit of 148 Bq.m-3 and 150 Bq.l-1, for, air and tap water, respectively. The average effective dose for TINT’s workers due to indoor radon exposure was approximately 0.20±0.11 mSv.y-1. The value is 100 times less than the annual dose limit for limit occupational radiation worker defined by the International Commission on Radiological Protection (ICRP). As a result, the TINT’s workplaces are radiologically safe from radon content in air and tap water.
Title: Investigation of radon level in air and tap water of workplaces at Thailand Institute of Nuclear Technology, Thailand
Description:
Abstract Thailand Institute of Nuclear Technology (TINT) has continuously monitored radiation exposure and radionuclide in workplaces specifically radon gas to estimate effective dose for workers.
Radon exposure is the second leading cause of lung cancer in the world.
In this study, radon in air and tap water at building no.
3, 7, 8, 9 and 18 on Ongkharak site of TINT have been measured for 5 years from 2012 to 2016.
Radon level in air and tap water were investigated on 83 stations (workplaces) and 54 samples, respectively.
Radon concentrations in air and tap water were measured by using the pulsed ionization chamber (ATMOS 12 DPX).
Indoor radon concentrations in air were in the range of 12-138 Bq.
m-3 with an average value of 30.
13±17.
05 Bq.
m-3.
Radon concentrations in tap water were in the range of 0.
10 to 2.
89 Bq.
l-1 with an average value of 0.
51±0.
55 Bq.
l-1.
The results of radon concentrations at TINT were below the US Environmental Protection Agency (US EPA) safety limit of 148 Bq.
m-3 and 150 Bq.
l-1, for, air and tap water, respectively.
The average effective dose for TINT’s workers due to indoor radon exposure was approximately 0.
20±0.
11 mSv.
y-1.
The value is 100 times less than the annual dose limit for limit occupational radiation worker defined by the International Commission on Radiological Protection (ICRP).
As a result, the TINT’s workplaces are radiologically safe from radon content in air and tap water.

Related Results

RADIATION CHARACTERISTICS OF KHMILNYK RADON GROUNDWATER
RADIATION CHARACTERISTICS OF KHMILNYK RADON GROUNDWATER
Ground waters of plutonic acid rock bodies tend to have a high radon content. Using radon-high domestic and medicinal waters could be a factor in contaminating the indoor air and i...
Development of uranium exploration methods using adon
Development of uranium exploration methods using adon
This report gives the results of tests carried out during the 1968 field season to determine the applicability of the radon method for detailed prospecting for uranium. Radon tests...
Strongly Radioactive Springs Discovered in Masutomi
Strongly Radioactive Springs Discovered in Masutomi
Abstract (1) A number of strongly radioactive springs were discovered in Masutomi, Yamanasi Prefecture. (2) The radon content of a number of very smal...
EXPLORING RADON: FROM SOURCES AND MIGRATION FACTORS TO HEALTH EFFECTS AND MITIGATION STRATEGIES
EXPLORING RADON: FROM SOURCES AND MIGRATION FACTORS TO HEALTH EFFECTS AND MITIGATION STRATEGIES
Radon, a naturally occurring radioactive noble gas, is colorless, odorless, and can be found in indoor and outdoor air, water, and soil. It is responsible for approximately 50% of ...
Radon Gas Exposure in Japan: Public Health Risks, Regulations, and Mitigation Strategies
Radon Gas Exposure in Japan: Public Health Risks, Regulations, and Mitigation Strategies
Abstract Radon (222Rn) is a naturally occurring radioactive gas and a significant cause of lung cancer globally, second only to inhaled tobacco smoke. This review examine...
The Research on the Influence of Degassing Temperatures of Water Samples on Radon Observations
The Research on the Influence of Degassing Temperatures of Water Samples on Radon Observations
Radon is a naturally emitted gas that is observed in soils, subsoils, air, and all types of water. Because there is a statistically significant association observed between seismic...
Soil gas radon and soil permeability assessment: Mapping radon risk areas in Perak State, Malaysia
Soil gas radon and soil permeability assessment: Mapping radon risk areas in Perak State, Malaysia
In this study geogenic radon potential (GRP) mapping was carried out on the bases of field radon in soil gas concentration and soil gas permeability measurements by considering the...

Back to Top