Javascript must be enabled to continue!
Seismic Evaluation of RC Asymmetric Building Consisting of Floating Column and Passive Device
View through CrossRef
The abrupt slip on a fault that causes earthquakes causes the ground to tremble. Earthquakes have been happening frequently all around the planet over the past several decades. Nearly all earthquakes cause direct damage to the buildings, which results in the destruction of life and property. Due to lack of following structural guidelines which lead to collapse, so carried out modern seismic reduction techniques base isolation, shear wall, dampers, which helps in earthquake resistant structures for better performance during seismic events. The energy dissipation devices are easy to installed in existing or new building with low construction cost.So past studied has been done on fluid viscous damper, Tune mass damper, viscous damper with multi storied regular building. In present study comparing with fluid viscous damper in RC Asymmetric layout C & H shape having G+12storey building with consisting Floating column at alternative floor. Time-History analysis has been done by using two different earthquakes taken from PEER ground motion having high and low Pga value. To learn the analytical effects like change in Axial force, Bending moment of Floating column with fluid viscous damper at different location. Also, Optimization of Damper position has been carried out using parameters like storey displacement, storey drift, storey stiffness
Title: Seismic Evaluation of RC Asymmetric Building Consisting of Floating Column and Passive Device
Description:
The abrupt slip on a fault that causes earthquakes causes the ground to tremble.
Earthquakes have been happening frequently all around the planet over the past several decades.
Nearly all earthquakes cause direct damage to the buildings, which results in the destruction of life and property.
Due to lack of following structural guidelines which lead to collapse, so carried out modern seismic reduction techniques base isolation, shear wall, dampers, which helps in earthquake resistant structures for better performance during seismic events.
The energy dissipation devices are easy to installed in existing or new building with low construction cost.
So past studied has been done on fluid viscous damper, Tune mass damper, viscous damper with multi storied regular building.
In present study comparing with fluid viscous damper in RC Asymmetric layout C & H shape having G+12storey building with consisting Floating column at alternative floor.
Time-History analysis has been done by using two different earthquakes taken from PEER ground motion having high and low Pga value.
To learn the analytical effects like change in Axial force, Bending moment of Floating column with fluid viscous damper at different location.
Also, Optimization of Damper position has been carried out using parameters like storey displacement, storey drift, storey stiffness.
Related Results
4D Seismic on Gullfaks
4D Seismic on Gullfaks
SUMMARY
New technologies are rapidly emerging helping to obtain optimal drainage of large reservoirs. 4D seismic is such a reservoir monitoring technique. The phy...
Seismic Frequency Enhancement for Mapping and Reservoir Characterization of Arab Formation: Case Study Onshore UAE
Seismic Frequency Enhancement for Mapping and Reservoir Characterization of Arab Formation: Case Study Onshore UAE
Abstract
Mapping and discrimination of Upper Jurassic Arab reservoirs (Arab A/B/C and D) in this 3D seismic onshore field of Abu Dhabi, is very sensitive to the seis...
Integrated Hydrocarbon Detection Based on Full Frequency Pre-Stack Seismic Inversion
Integrated Hydrocarbon Detection Based on Full Frequency Pre-Stack Seismic Inversion
Abstract
To improve the accuracy of hydrocarbon detection, seismic amplitude variation with offset (AVO), seismic amplitude variation with frequency (AVF), and direc...
General classification of seismic protection systems of buildings and structures
General classification of seismic protection systems of buildings and structures
The issues of ensuring the seismic resistance of buildings and structures hold a leading position despite significant achievements in this area. This is confirmed by the significan...
A Comprehensive Evaluation Method for Assessing the Seismic Resilience of Building Sites Based on the TOPSIS Model and the Entropy Method
A Comprehensive Evaluation Method for Assessing the Seismic Resilience of Building Sites Based on the TOPSIS Model and the Entropy Method
The seismic design philosophy based on resilience represents the latest development in structural seismic design theory and is currently the most advanced concept in the field of s...
Kajian Pengembangan Sediaan Floating Sustained Release Tablet
Kajian Pengembangan Sediaan Floating Sustained Release Tablet
Abstract. Floating sustained release tablets were developed to increase the elimination half-life and bioavailability of the drug because it is able to release the active substance...
Future Directions of Multicomponent Seismic Methods in the Marine Environment
Future Directions of Multicomponent Seismic Methods in the Marine Environment
Abstract
Multicomponent seismic recording (4C) is becoming more common in several offshore seismic applications. Faithfully recording all Cartesian components of ...
Reservoir-oriented migrated seismic image improvement and poststack seismic inversion using well-seismic mistie
Reservoir-oriented migrated seismic image improvement and poststack seismic inversion using well-seismic mistie
Abstract
In seismic exploration of subsurface hydrocarbon reservoirs, migrated seismic images are the foundation of structural interpretation and subsequent seism...

