User Oriented Calibration Method for Stonex X300 Terrestrial Laser Scanner
View through CrossRef
Terrestrial laser scanners (TLSs) are 3D imaging systems that provide the most powerful 3D representation and practical solutions for various applications. Hence this is due to effective range measurements, 3D point cloud reliability, and rapid acquisition performance. Stonex X300 TOF scanner delivered better certainty in far-range than in close-range measurements due to the high noise level inherent within the data delivered from Time of Flight (TOF) scanning sensors. However, if these errors are manipulated properly using a valid calibration model, more accurate products can be obtained even from very close-range measurements. Therefore, to fill this gap, this research presents a user-oriented target-based calibration routine to compute the calibration parameters of Stonex X300 TLS. The proposed routine investigates range and angular measurements to mitigate mechanical misalignment error sources of this device.
Distance and angular index errors were computed, and environmental error sources were considered for optimal modeling estimation. The approach is based to reference measurements in a close-range environment within a 10-meter distance to user-defined ground truth targets. Experiment results show that the errors in the distance are generally increased following the increase in range distance between the laser device and the targets. However, error variations between laser and reference measurements nearly constant relational to the range value. The index error of the Stonex X300 was computed based on mean measurements and found to be equal to 4.6717 mm.
On the other hand, the horizontal angular measurements delivered from the TLS device were found to be more consistent with the reference measurements than with thee vertical angular measurements. However, the vertical angular measurements show more significant variations in particular measures compared to horizontal angular measurements. Following this, the angular error index was computed and found to be equal to 0.07 seconds and 0.13 seconds in horizontal and vertical angular measurements, respectively.
University of Baghdad College of Science
Title: User Oriented Calibration Method for Stonex X300 Terrestrial Laser Scanner
Description:
Terrestrial laser scanners (TLSs) are 3D imaging systems that provide the most powerful 3D representation and practical solutions for various applications.
Hence this is due to effective range measurements, 3D point cloud reliability, and rapid acquisition performance.
Stonex X300 TOF scanner delivered better certainty in far-range than in close-range measurements due to the high noise level inherent within the data delivered from Time of Flight (TOF) scanning sensors.
However, if these errors are manipulated properly using a valid calibration model, more accurate products can be obtained even from very close-range measurements.
Therefore, to fill this gap, this research presents a user-oriented target-based calibration routine to compute the calibration parameters of Stonex X300 TLS.
The proposed routine investigates range and angular measurements to mitigate mechanical misalignment error sources of this device.
Distance and angular index errors were computed, and environmental error sources were considered for optimal modeling estimation.
The approach is based to reference measurements in a close-range environment within a 10-meter distance to user-defined ground truth targets.
Experiment results show that the errors in the distance are generally increased following the increase in range distance between the laser device and the targets.
However, error variations between laser and reference measurements nearly constant relational to the range value.
The index error of the Stonex X300 was computed based on mean measurements and found to be equal to 4.
6717 mm.
On the other hand, the horizontal angular measurements delivered from the TLS device were found to be more consistent with the reference measurements than with thee vertical angular measurements.
However, the vertical angular measurements show more significant variations in particular measures compared to horizontal angular measurements.
Following this, the angular error index was computed and found to be equal to 0.
07 seconds and 0.
13 seconds in horizontal and vertical angular measurements, respectively.
Related Results
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...
Excimer Laser Micromachining of MEMS Materials
Excimer Laser Micromachining of MEMS Materials
Conventional photolithography-based microfabrication techniques are limited to two-dimensional fabrication and only particular materials can be used. Excimer laser micromachining e...
Laser show safety for smaller shows: The ILDA category a laser show standard
Laser show safety for smaller shows: The ILDA category a laser show standard
The International Laser Display Association has developed a “Category A Standard” for laser shows that ILDA considers to be generally recognized as safe under the conditions of the...
Development of a high intensity Mid-Ir OPCPA pumped by a HO:YLF amplifier
Development of a high intensity Mid-Ir OPCPA pumped by a HO:YLF amplifier
The continuous development of laser sources delivering ultra-short light pulses underpins much of the current progress in experimental science, particularly in the domain of physic...
Laser Cladded Surface Hardening Coating With Gradient of Mechanical Properties
Laser Cladded Surface Hardening Coating With Gradient of Mechanical Properties
The present dissertation “Laser Cladded Surface Hardening Coating with Gradient of Mechanical Properties” is devoted to the research of laser cladding process for obtaining high qu...
A calibration method combining hand-eye calibration and TCP calibration
A calibration method combining hand-eye calibration and TCP calibration
Abstract
Robots' traditional Tool Center Point (TCP) calibration and hand-eye calibration are implemented independently, which is likely to generate large cumulative errors...
Evaluation of laser scanning technology for bridge inspection
Evaluation of laser scanning technology for bridge inspection
In United States, there are almost 600,000 highway bridges. The average life time of these bridges is about 70 years. When bridges reach their mid-life, some damages on structures ...