Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Biomechanical comparison of proximal, distal, and anatomic tibial tunnel for transtibial posterior cruciate ligament reconstruction

View through CrossRef
No consensus has been reached on the optimal position of PCL tibial tunnel. The purpose of this study was to compare the biomechanical properties of proximal, distal and anatomic tibial tunnel in transtibial posterior cruciate ligament reconstruction. An in-vitro model of transtibial posterior cruciate ligament reconstruction was simulated using porcine tibias and bovine extensor tendons. Two models of biomechanical testing, load-to-failure loading, and cyclic loading, were performed in this study. The load-to-failure loading found that distal tibial tunnel resulted in greater ultimate load and yield load than the anatomic and proximal tunnel group ( p < 0.05), whereas there were no significant differences in mean tensile stiffness among three groups ( p > 0.05). The cyclic loading found no differences in the graft displacement at 250, 500, and 1000 cycles among three groups ( p > 0.05). It was found that distal tibial tunnel showed superior ultimate load and yield load in load-to-failure loading testing compared with proximal and anatomic tibial tunnels, whereas no significant difference was found in terms of the mean displacement of the survived grafts in cyclic loading testing among three groups.
Title: Biomechanical comparison of proximal, distal, and anatomic tibial tunnel for transtibial posterior cruciate ligament reconstruction
Description:
No consensus has been reached on the optimal position of PCL tibial tunnel.
The purpose of this study was to compare the biomechanical properties of proximal, distal and anatomic tibial tunnel in transtibial posterior cruciate ligament reconstruction.
An in-vitro model of transtibial posterior cruciate ligament reconstruction was simulated using porcine tibias and bovine extensor tendons.
Two models of biomechanical testing, load-to-failure loading, and cyclic loading, were performed in this study.
The load-to-failure loading found that distal tibial tunnel resulted in greater ultimate load and yield load than the anatomic and proximal tunnel group ( p < 0.
05), whereas there were no significant differences in mean tensile stiffness among three groups ( p > 0.
05).
The cyclic loading found no differences in the graft displacement at 250, 500, and 1000 cycles among three groups ( p > 0.
05).
It was found that distal tibial tunnel showed superior ultimate load and yield load in load-to-failure loading testing compared with proximal and anatomic tibial tunnels, whereas no significant difference was found in terms of the mean displacement of the survived grafts in cyclic loading testing among three groups.

Related Results

Proximal Tibial Epiphysiodesis in a Growing Dog
Proximal Tibial Epiphysiodesis in a Growing Dog
 Background: It is believed that the inclined tibial plateau angle to be a major cause of cranial cruciate ligament (CCL) rupture, and the treatment of this disease is the tibial p...
Mucoid Degeneration of Posterior Cruciate Ligament – A Case Study
Mucoid Degeneration of Posterior Cruciate Ligament – A Case Study
Introduction: Mucoid degeneration of the cruciate ligament is a well-known entity, but symptomatic lesions are rare. It is even rarer to find symptomatic posterior cruciate ligamen...
The Anatomic Characteristics of the Tibial Insertion of the Posterior Cruciate Ligament
The Anatomic Characteristics of the Tibial Insertion of the Posterior Cruciate Ligament
Purpose The purpose of the study was to better define the tibial insertion of the posterior cruciate ligament (PCL) and to identify landmarks that could be used...
Radiographic analysis of Re-Ruptures of reconstructed ACLs - Evaluation of tunnel position as a possible cause of Failure
Radiographic analysis of Re-Ruptures of reconstructed ACLs - Evaluation of tunnel position as a possible cause of Failure
Objectives: Previous studies detected femoral and / or tibial tunnel malpositioning as possible causes for the failure of an anterior cruciate ligament reconstr...
Perbedaan Pengaruh Penggunaan Prostesis Transtibial Terhadap Kepercayaan Diri Pada Pasien Post Amputasi
Perbedaan Pengaruh Penggunaan Prostesis Transtibial Terhadap Kepercayaan Diri Pada Pasien Post Amputasi
Abstract: The use of prosthesis, Social Status, Confidence. This study aimed to analyze the effect of using transtibial prosthesis (artificial leg) and social status of the self-es...

Back to Top