Shear Bond Strength Comparison Between Heat Cure Acrylic Resin and Other Types of Acrylic Denture Bases
View through CrossRef
Objective: The study purpose was to examine the shear bonding strength of heat cure acrylic resin to thermoplastic resin and three-dimensional printed resin materials.
Methods: A total of 30 acrylic specimens were fabricated in this study. Each specimen had a basal and top parts. The basal part was rectangular in shape. We had three different groups: 10 specimens of a basal part made of heat cured polymethylmethacrylate, 10 specimens of a basal part made of thermoplastic, and 10 specimens of three dimensionally printed resin. The top part of which is attached to the basal one was formed into a cylindrical shape made of heat cure poly methyl methacrylate in all three groups.
Results: Significant differences were found between the heat cured polymethylmethacrylate and the other two groups (P<.001). Heat cured polymethylmethacrylate showed the highest bond strength (75 MPa), and thermoplastic resins showed the lowest (37 MPa). No significant difference in the shear bond strength was noticed between three dimensionally printed and thermoplastic acrylic.
Conclusion: This study revealed that the shear bond strength of heat cured acrylic denture base to the relining/repairing from the same material was significantly higher than three dimensionally printed and thermoplastic resins with HC relining/repairing material.
University Library System, University of Pittsburgh
Title: Shear Bond Strength Comparison Between Heat Cure Acrylic Resin and Other Types of Acrylic Denture Bases
Description:
Objective: The study purpose was to examine the shear bonding strength of heat cure acrylic resin to thermoplastic resin and three-dimensional printed resin materials.
Methods: A total of 30 acrylic specimens were fabricated in this study.
Each specimen had a basal and top parts.
The basal part was rectangular in shape.
We had three different groups: 10 specimens of a basal part made of heat cured polymethylmethacrylate, 10 specimens of a basal part made of thermoplastic, and 10 specimens of three dimensionally printed resin.
The top part of which is attached to the basal one was formed into a cylindrical shape made of heat cure poly methyl methacrylate in all three groups.
Results: Significant differences were found between the heat cured polymethylmethacrylate and the other two groups (P<.
001).
Heat cured polymethylmethacrylate showed the highest bond strength (75 MPa), and thermoplastic resins showed the lowest (37 MPa).
No significant difference in the shear bond strength was noticed between three dimensionally printed and thermoplastic acrylic.
Conclusion: This study revealed that the shear bond strength of heat cured acrylic denture base to the relining/repairing from the same material was significantly higher than three dimensionally printed and thermoplastic resins with HC relining/repairing material.
Related Results
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Contemporary methods and mobile denture cleansers and theirs significance for older population
Contemporary methods and mobile denture cleansers and theirs significance for older population
Introduction. A dramatic increase in the number of people living in their
seventies, eighties and nineties is associated with a loss of teeth and the
use of mobile dentures. ...
The Surface roughness of acrylic denture base immersed with herbal denture cleanser
The Surface roughness of acrylic denture base immersed with herbal denture cleanser
Background: Plaque accumulation on dentures can be prevented through daily denture cleaning. Currently, commercially available denture cleansers, such as the chemical-based product...
Prevention of inflammatory changes in the denture-bearing mucous membrane
Prevention of inflammatory changes in the denture-bearing mucous membrane
Relevance. Advanced clinical and cytological studies have not been conducted yet to examine denture adhesive effect on the prevention of inflammatory changes in the mucous membrane...
Estimation Of Adherance Of Candida Albicans To Different Denture Base Materials And Its Relationship With Denture Stomatitis – An In Vivo Study
Estimation Of Adherance Of Candida Albicans To Different Denture Base Materials And Its Relationship With Denture Stomatitis – An In Vivo Study
Background - Candida albicans is the most common human oral fungi frequently recovered from the denture surface causing denture stomatitis. Modern treatment approaches suppress th...
PENGARUH PERIODE PEMANENAN RESIN DAMAR TERHADAP PENDAPATAN PETANI REPONG DAMAR DI PEKON LABUHAN MANDI PESISIR BARAT
PENGARUH PERIODE PEMANENAN RESIN DAMAR TERHADAP PENDAPATAN PETANI REPONG DAMAR DI PEKON LABUHAN MANDI PESISIR BARAT
Repong Damar is a plot of land planted with various types of productive plants from various types of timber with economic value. The term repong damar is because the plant that is ...
The Effect of Nano Hydroxyapatite on the Bond Strength of Acrylic Teeth Repaired to an Acrylic Resin Denture Base Using Two Types of Auto Polymerized Acrylic Resins
The Effect of Nano Hydroxyapatite on the Bond Strength of Acrylic Teeth Repaired to an Acrylic Resin Denture Base Using Two Types of Auto Polymerized Acrylic Resins
The insufficiently binder between acrylic teeth and dentures is considered to be the primary cause of teeth fractures from the dentures and is one of the disadvantages of acrylic d...
Observations of the soil particle movement during direct shear tests on soil-geosynthetic interfaces
Observations of the soil particle movement during direct shear tests on soil-geosynthetic interfaces
The shear strength between soil-geosynthetic interface has been well studied by conducting large scale direct shear tests. However, the documents of the development of shear band a...