Javascript must be enabled to continue!
Passive islanding detection scheme based on autocorrelation function of modal current envelope for photovoltaic units
View through CrossRef
Islanding detection in power systems poses a challenge that can result in technical problems and safety hazards. This study examines a new passive islanding detection method for photovoltaic‐based distributed generation (DG) units. The modal signal of the three‐phase current and its envelope are calculated for a targeted DG unit. Variance in the autocorrelation of the modal current envelope (VAMCE) is used as an islanding detection criterion in the proposed method. The proposed method employs autocorrelation function (ACF) of modal current envelope (derived by Hilbert‐transform‐based approach) to extract the transient content. Then, the variance of the ACF is calculated, called criterion VAMCE to distinguish between islanded and normal operating conditions. The main advantage of the proposed technique is more relevant to its more accuracy and smaller non‐detection zone in comparison with the other similar passive techniques. Since the VAMCE has significant variation during islanding conditions and negligible change in normal conditions, it can be used for detection of islanding condition effectively. The method was evaluated through several simulations under different islanded and normal operating conditions. The results confirm that the proposed method has better accuracy and speed compared to other similar methods.
Institution of Engineering and Technology (IET)
Title: Passive islanding detection scheme based on autocorrelation function of modal current envelope for photovoltaic units
Description:
Islanding detection in power systems poses a challenge that can result in technical problems and safety hazards.
This study examines a new passive islanding detection method for photovoltaic‐based distributed generation (DG) units.
The modal signal of the three‐phase current and its envelope are calculated for a targeted DG unit.
Variance in the autocorrelation of the modal current envelope (VAMCE) is used as an islanding detection criterion in the proposed method.
The proposed method employs autocorrelation function (ACF) of modal current envelope (derived by Hilbert‐transform‐based approach) to extract the transient content.
Then, the variance of the ACF is calculated, called criterion VAMCE to distinguish between islanded and normal operating conditions.
The main advantage of the proposed technique is more relevant to its more accuracy and smaller non‐detection zone in comparison with the other similar passive techniques.
Since the VAMCE has significant variation during islanding conditions and negligible change in normal conditions, it can be used for detection of islanding condition effectively.
The method was evaluated through several simulations under different islanded and normal operating conditions.
The results confirm that the proposed method has better accuracy and speed compared to other similar methods.
Related Results
A Comprehensive overview of Classification-enabled Machine Learning Algorithms for Islanding Detection Techniques
A Comprehensive overview of Classification-enabled Machine Learning Algorithms for Islanding Detection Techniques
Abstract
In modern distribution networks, addressing the issue of unintentional islanding – characterized as the inadvertent disconnection of distributed generati...
An Anti-Islanding Protection Method Based on Voltage-Synchronous Impedance Angle Measurements
An Anti-Islanding Protection Method Based on Voltage-Synchronous Impedance Angle Measurements
Grid-tied distributed generators (DGs) need to be equipped with anti-islanding protection to avoid the impact of unplanned islanding, which would affect system stability, auto-recl...
RES Based Islanded DC Microgrid with Enhanced Electrical Network Islanding Detection
RES Based Islanded DC Microgrid with Enhanced Electrical Network Islanding Detection
An electrical islanding detection method for DC microgrid (MG) is proposed in this paper. Unlikely conventional AC MG system protection has been challenging for the DC MG system. T...
Islanding detection method for multi‐terminal renewable power DC distribution system
Islanding detection method for multi‐terminal renewable power DC distribution system
Abstract
Most of the traditional islanding detection methods are designed for renewable sources in AC systems and cannot be directly applied in multi‐terminal DC ...
Islanding Detection Methods for Microgrids: A Comprehensive Review
Islanding Detection Methods for Microgrids: A Comprehensive Review
Microgrids that are integrated with distributed energy resources (DERs) provide many benefits, including high power quality, energy efficiency and low carbon emissions, to the powe...
An Efficient Hybrid Islanding Detection Method for Microgrids Using Kalman Filter
An Efficient Hybrid Islanding Detection Method for Microgrids Using Kalman Filter
ABSTRACT
Islanding condition gives rise to several problems in distributed generation networks, including power quality disturbances, equipment damage, interferen...
Sequence Component-Based Improved Passive Islanding Detection Method for Distribution System with Distributed Generations
Sequence Component-Based Improved Passive Islanding Detection Method for Distribution System with Distributed Generations
Abstract
In distributed generation (DG) systems, the rate of change of voltage and the rate of change of frequency are the two most common and widely used simple and low-cost passi...
An Extensive Overview of Islanding Detection Strategies of Active Distributed Generations in Sustainable Microgrids
An Extensive Overview of Islanding Detection Strategies of Active Distributed Generations in Sustainable Microgrids
Active distributed generations (ADGs) are more prevalent near consumer premises. However, the ADG penetration contribute a lot of dynamic changes in power distribution networks whi...