Clinical outcomes of subcutaneous vs. transvenous implantable defibrillator therapy in a polymorbid patient cohort
View through CrossRef
BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis. Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017. By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).ResultsThe median age of the study population was 66.0 years, 22.7% of the patients were female. The underlying heart disease was ischemic cardiomyopathy (61.4%) with a median LVEF of 30%. Only 52.9% had received an ICD for primary prevention, most of the patients (67.3%) had advanced heart failure (NYHA class II–III) and 16.8% were in atrial fibrillation. CCI was 5 points in TV-ICD patients vs. 4 points for patients with S-ICD (p = 0.209) indicating increased morbidity. The composite endpoint occurred in 38 patients (31.9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.50, 95 % confidence interval (CI) 0.78–2.90; p = 0.229, weighted HR 0.94, 95% CI, 0.61–1.50, p = 0.777). Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders. Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Title: Clinical outcomes of subcutaneous vs. transvenous implantable defibrillator therapy in a polymorbid patient cohort
Description:
BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis.
Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).
ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.
MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017.
By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).
ResultsThe median age of the study population was 66.
0 years, 22.
7% of the patients were female.
The underlying heart disease was ischemic cardiomyopathy (61.
4%) with a median LVEF of 30%.
Only 52.
9% had received an ICD for primary prevention, most of the patients (67.
3%) had advanced heart failure (NYHA class II–III) and 16.
8% were in atrial fibrillation.
CCI was 5 points in TV-ICD patients vs.
4 points for patients with S-ICD (p = 0.
209) indicating increased morbidity.
The composite endpoint occurred in 38 patients (31.
9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.
50, 95 % confidence interval (CI) 0.
78–2.
90; p = 0.
229, weighted HR 0.
94, 95% CI, 0.
61–1.
50, p = 0.
777).
Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.
ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders.
Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Related Results
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Introduction:
There is limited evidence guiding the selection between subcutaneous and transvenous ICD in patients with arrhythmogenic right ventricular cardiomyopathy ...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Trends in Use and In-Hospital Outcomes of Subcutaneous Implantable Cardioverter Defibrillators in Patients Undergoing Long-Term Dialysis
Trends in Use and In-Hospital Outcomes of Subcutaneous Implantable Cardioverter Defibrillators in Patients Undergoing Long-Term Dialysis
Background and objectives
Patients on dialysis are at high risk of complications related to implantable cardioverter defibrillator (ICD) implantation; use of subcutaneo...
Pembrolizumab and Sarcoma: A meta-analysis
Pembrolizumab and Sarcoma: A meta-analysis
Abstract
Introduction: Pembrolizumab is a monoclonal antibody that promotes antitumor immunity. This study presents a systematic review and meta-analysis of the efficacy and safety...
IMPLANTABLE DEFIBRILLATOR LEAD EXTRACTION WITH OPTIMISED STANDARD EXTRACTION TECHNIQUES
IMPLANTABLE DEFIBRILLATOR LEAD EXTRACTION WITH OPTIMISED STANDARD EXTRACTION TECHNIQUES
Objectives
Implantable cardioverter-defibrillator (ICD) leads might not be extracted in especially developing countries because of the high cost and lack of speci...
Implantable antennas for biomedical applications: a systematic review
Implantable antennas for biomedical applications: a systematic review
AbstractThis review presents an in-depth examination of implantable antennas for various biomedical purposes. The development of implantable antennas, including their designs, mate...
Stable Factor IX Expression and Sustained Reductions in Factor IX Use 8 Years after Gene Therapy with CSL220 (Formerly AMT-060) in Adults with Hemophilia B
Stable Factor IX Expression and Sustained Reductions in Factor IX Use 8 Years after Gene Therapy with CSL220 (Formerly AMT-060) in Adults with Hemophilia B
Introduction: CSL220 (formerly AMT-060) is an adeno-associated virus serotype 5 (AAV5) vector encoding a codon-optimized wild-type human factor IX (FIX) gene, driven by a liver-spe...
P1508A single center analysis of a 10-year period of lead removal
P1508A single center analysis of a 10-year period of lead removal
Abstract
BACKGROUND
The number of lead removal of cardiac implantable electronic devices (CIED) has increased in recent years. T...