Javascript must be enabled to continue!
Clinical outcomes of subcutaneous vs. transvenous implantable defibrillator therapy in a polymorbid patient cohort
View through CrossRef
BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis. Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017. By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).ResultsThe median age of the study population was 66.0 years, 22.7% of the patients were female. The underlying heart disease was ischemic cardiomyopathy (61.4%) with a median LVEF of 30%. Only 52.9% had received an ICD for primary prevention, most of the patients (67.3%) had advanced heart failure (NYHA class II–III) and 16.8% were in atrial fibrillation. CCI was 5 points in TV-ICD patients vs. 4 points for patients with S-ICD (p = 0.209) indicating increased morbidity. The composite endpoint occurred in 38 patients (31.9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.50, 95 % confidence interval (CI) 0.78–2.90; p = 0.229, weighted HR 0.94, 95% CI, 0.61–1.50, p = 0.777). Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders. Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Title: Clinical outcomes of subcutaneous vs. transvenous implantable defibrillator therapy in a polymorbid patient cohort
Description:
BackgroundThe subcutaneous implantable cardioverter-defibrillator (S-ICD) has been designed to overcome lead-related complications and device endocarditis.
Lacking the ability for pacing or resynchronization therapy its usage is limited to selected patients at risk for sudden cardiac death (SCD).
ObjectiveThe aim of this single-center study was to assess clinical outcomes of S-ICD and single-chamber transvenous (TV)-ICD in an all-comers population.
MethodsThe study cohort comprised a total of 119 ICD patients who underwent either S-ICD (n = 35) or TV-ICD (n = 84) implantation at the University Hospital Frankfurt from 2009 to 2017.
By applying an inverse probability-weighting (IPW) analysis based on the propensity score including the Charlson Comorbidity Index (CCI) to adjust for potential extracardiac comorbidities, we aimed for head-to-head comparison on the study composite endpoint: overall survival, hospitalization, and device-associated events (including appropriate and inappropriate shocks or system-related complications).
ResultsThe median age of the study population was 66.
0 years, 22.
7% of the patients were female.
The underlying heart disease was ischemic cardiomyopathy (61.
4%) with a median LVEF of 30%.
Only 52.
9% had received an ICD for primary prevention, most of the patients (67.
3%) had advanced heart failure (NYHA class II–III) and 16.
8% were in atrial fibrillation.
CCI was 5 points in TV-ICD patients vs.
4 points for patients with S-ICD (p = 0.
209) indicating increased morbidity.
The composite endpoint occurred in 38 patients (31.
9 %), revealing no significant difference between patients implanted with an S-ICD or TV-ICD (unweighted HR 1.
50, 95 % confidence interval (CI) 0.
78–2.
90; p = 0.
229, weighted HR 0.
94, 95% CI, 0.
61–1.
50, p = 0.
777).
Furthermore, we observed no difference in any single clinical endpoint or device-associated outcome, neither in the unweighted cohort nor following inverse probability-weighting.
ConclusionClinical outcomes of the S-ICD and TV-ICD revealed no differences in the composite endpoint including survival, freedom of hospitalization and device-associated events, even after careful adjustment for potential confounders.
Moreover, the CCI was evaluated in a S-ICD cohort demonstrating higher survival rates than predicted by the CCI in young, polymorbid (S-)ICD patients.
Related Results
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Introduction:
There is limited evidence guiding the selection between subcutaneous and transvenous ICD in patients with arrhythmogenic right ventricular cardiomyopathy ...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
IMPLANTABLE DEFIBRILLATOR LEAD EXTRACTION WITH OPTIMISED STANDARD EXTRACTION TECHNIQUES
IMPLANTABLE DEFIBRILLATOR LEAD EXTRACTION WITH OPTIMISED STANDARD EXTRACTION TECHNIQUES
Objectives
Implantable cardioverter-defibrillator (ICD) leads might not be extracted in especially developing countries because of the high cost and lack of speci...
Stable Factor IX Expression and Sustained Reductions in Factor IX Use 8 Years after Gene Therapy with CSL220 (Formerly AMT-060) in Adults with Hemophilia B
Stable Factor IX Expression and Sustained Reductions in Factor IX Use 8 Years after Gene Therapy with CSL220 (Formerly AMT-060) in Adults with Hemophilia B
Introduction: CSL220 (formerly AMT-060) is an adeno-associated virus serotype 5 (AAV5) vector encoding a codon-optimized wild-type human factor IX (FIX) gene, driven by a liver-spe...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
P186 LEADLESS PACEMAKER VERSUS TRANSVENOUS PACEMAKER: THE BEST ALTERNATIVE FOR THE POST–EXTRACTION PATIENT
P186 LEADLESS PACEMAKER VERSUS TRANSVENOUS PACEMAKER: THE BEST ALTERNATIVE FOR THE POST–EXTRACTION PATIENT
Abstract
Introduction
As complications associated with pacemakers or defibrillators implant increase, the number of patients und...
The Influence of Subcutaneous and Visceral Adipocyte Geometries on Metabolic Parameters and Metabolic Regulating Hormones in Obese and Non-Obese Subjects
The Influence of Subcutaneous and Visceral Adipocyte Geometries on Metabolic Parameters and Metabolic Regulating Hormones in Obese and Non-Obese Subjects
Adipose tissue plays a pivotal role in endocrine and metabolic homeostasis. This study aimed to compare subcutaneous and visceral adipocyte measurements, including area, shortest d...
OPTIMIZED TREATMENT OF MEN’S HYPOHONADISM
OPTIMIZED TREATMENT OF MEN’S HYPOHONADISM
Aim: to study the effectiveness of different treatment options for male hypogonadism. Material and methods: the paper investigates outcomes in treating male hypogonadism (86 patie...