Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Calculated globulin (CG) as a screening test for antibody deficiency

View through CrossRef
Summary Calculated globulin (total protein – albumin) is usually tested as part of a liver function test profile in both primary and secondary care and determines the serum globulin concentration, of which immunoglobulins are a major component. The main use hitherto of calculated globulin is to detect paraproteins when the level is high. This study investigated the potential to use low levels of calculated globulin to detect antibody deficiency. Serum samples with calculated globulin cut-off < 18 g/l based on results of a pilot study were collected from nine hospitals in Wales over a 12-month period. Anonymized request information was obtained and the samples tested for immunoglobulin levels, serum electrophoresis and, if appropriate, immunofixation. A method comparison for albumin measurement using bromocresol green and bromocresol purple was undertaken. Eighty-nine per cent (737 of 826) samples had an immunoglobulin (Ig)G level of < 6 g/l using the bromocresol green methodology with a cut-off of < 18 g/l, and 56% (459) had an IgG of < 4 g/l. Patients with both secondary and primary antibody deficiency were discovered and serum electrophoresis and immunofixation showed that 1·2% (10) had previously undetected small paraproteins associated with immune-paresis. Using bromocresol purple, 74% of samples had an IgG of < 6 g/l using a cut-off of < 23 g/l. Screening using calculated globulin with defined cut-off values detects both primary and secondary antibody deficiency and new paraproteins associated with immune-paresis. It is cheap, widely available and under-utilized. Antibody-deficient patients have been discovered using information from calculated globulin values, shortening diagnostic delay and time to treatment with immunoglobulin replacement therapy.
Title: Calculated globulin (CG) as a screening test for antibody deficiency
Description:
Summary Calculated globulin (total protein – albumin) is usually tested as part of a liver function test profile in both primary and secondary care and determines the serum globulin concentration, of which immunoglobulins are a major component.
The main use hitherto of calculated globulin is to detect paraproteins when the level is high.
This study investigated the potential to use low levels of calculated globulin to detect antibody deficiency.
Serum samples with calculated globulin cut-off < 18 g/l based on results of a pilot study were collected from nine hospitals in Wales over a 12-month period.
Anonymized request information was obtained and the samples tested for immunoglobulin levels, serum electrophoresis and, if appropriate, immunofixation.
A method comparison for albumin measurement using bromocresol green and bromocresol purple was undertaken.
Eighty-nine per cent (737 of 826) samples had an immunoglobulin (Ig)G level of < 6 g/l using the bromocresol green methodology with a cut-off of < 18 g/l, and 56% (459) had an IgG of < 4 g/l.
Patients with both secondary and primary antibody deficiency were discovered and serum electrophoresis and immunofixation showed that 1·2% (10) had previously undetected small paraproteins associated with immune-paresis.
Using bromocresol purple, 74% of samples had an IgG of < 6 g/l using a cut-off of < 23 g/l.
Screening using calculated globulin with defined cut-off values detects both primary and secondary antibody deficiency and new paraproteins associated with immune-paresis.
It is cheap, widely available and under-utilized.
Antibody-deficient patients have been discovered using information from calculated globulin values, shortening diagnostic delay and time to treatment with immunoglobulin replacement therapy.

Related Results

Clinical Implications of Cytopenias in the U.S. Immunodeficiency Network Registry
Clinical Implications of Cytopenias in the U.S. Immunodeficiency Network Registry
Rationale The correlation between cytopenias and infection, malignancy, and mortality has not been systematically characterized in patients with inborn errors of ...
RETRACTED: Isolation and Characterization of Antibacterial Conglutinins from Lupine Seeds
RETRACTED: Isolation and Characterization of Antibacterial Conglutinins from Lupine Seeds
The main target of this work is to discover new protein fractions from natural resources with high antibacterial action. The 7S and 11S globulin fractions, as well as the basic sub...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
IgM antibody to hepatitis C virus in acute and chronic hepatitis C
IgM antibody to hepatitis C virus in acute and chronic hepatitis C
To assess possible role of testing for IgM-specific antibody in the diagnosis and monitoring of patients with hepatitis C, we tested sera from 14 patients with acute and 97 patient...
Mesoscale Modeling of a Nucleosome-Binding Antibody (PL2-6): Mono- vs. Bivalent Chromatin Complexes
Mesoscale Modeling of a Nucleosome-Binding Antibody (PL2-6): Mono- vs. Bivalent Chromatin Complexes
ABSTRACTVisualizing chromatin adjacent to the nuclear envelope (denoted “epichromatin”) by in vitro immunostaining with a bivalent nucleosome-binding antibody (termed monoclonal an...
Stability of Immune Globulin Intravenous, Human-stwk, 10% Liquid Following Pooling and Storage in Flexible Containers
Stability of Immune Globulin Intravenous, Human-stwk, 10% Liquid Following Pooling and Storage in Flexible Containers
Introduction Immune globulin intravenous, human-stwk, 10% liquid is indicated for the treatment of primary immunodeficiency disorders associated with defects in humoral immunity. U...
False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins
False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins
Background The polyethylene glycol (PEG) precipitation test is widely used to detect hyperprolactinaemia caused by macroprolactin. We report two cases of hyperprolactinaemia in whi...

Back to Top