Javascript must be enabled to continue!
An In Vitro Evaluation of Alumina, Zirconia, and Lithium Disilicate Surface Roughness Caused by Two Scaling Instruments
View through CrossRef
AbstractPurposePlaque control is crucial for the prevention of inflammatory periodontal disease. Hand scaling instruments have been shown to be efficient for the removal of plaque; however, routine periodontal prophylactic procedures may modify the surface profile of restorative materials. The purpose of this study was to assess in vitro the changes in roughness of alumina, zirconia, and lithium disilicate surfaces treated by two hand scaling instruments.Materials and MethodsForty‐eight alumina specimens, 48 zirconia specimens, and 48 lithium disilicate specimens, were selected. All specimens were divided into three groups of 16 each; one group for each material was considered the control group and no scaling procedures were performed; the second group of each material was exposed to scaling with steel curettes simulating standard clinical conditions; the third group of each material was exposed to scaling with titanium curettes. After scaling, the surface roughness of the specimens was evaluated with a profilometer. First, a statistical test was carried out to evaluate the difference in surface roughness before the scaling procedure of the three materials was effected (Kruskal‐Wallis test). Subsequently, the effect of curette material (steel and titanium) on roughness difference and roughness ratio was analyzed throughout the entire sample and within each material group, and a nonparametric test for dependent values was conducted (Wilcoxon signed‐rank test). Finally, the roughness ratios of the three material groups were compared by means of a Kruskal‐Wallis test and a Wilcoxon signed‐rank test. Upon completion of profilometric evaluation, representative specimens from each group were prepared for SEM evaluation to evaluate the effects of the two scaling systems on the different surfaces qualitatively.ResultsAfter scaling procedure, the roughness profile value increased in all disks. Classifying the full sample according to curette used, the roughness of the disks treated with a steel curette reached a higher median value than that of the titanium group. Zirconia demonstrated the least significant increase in surface roughness. The result was 3.9 times of the initial value as compared to 4.3 times for alumina and 4.6 times for lithium disilicate.ConclusionsComparison of profilometer readings before and after instrumentation, carried out with different hand scaling instruments, highlighted both a statistically and clinically relevant increase in material roughness.
Title: An In Vitro Evaluation of Alumina, Zirconia, and Lithium Disilicate Surface Roughness Caused by Two Scaling Instruments
Description:
AbstractPurposePlaque control is crucial for the prevention of inflammatory periodontal disease.
Hand scaling instruments have been shown to be efficient for the removal of plaque; however, routine periodontal prophylactic procedures may modify the surface profile of restorative materials.
The purpose of this study was to assess in vitro the changes in roughness of alumina, zirconia, and lithium disilicate surfaces treated by two hand scaling instruments.
Materials and MethodsForty‐eight alumina specimens, 48 zirconia specimens, and 48 lithium disilicate specimens, were selected.
All specimens were divided into three groups of 16 each; one group for each material was considered the control group and no scaling procedures were performed; the second group of each material was exposed to scaling with steel curettes simulating standard clinical conditions; the third group of each material was exposed to scaling with titanium curettes.
After scaling, the surface roughness of the specimens was evaluated with a profilometer.
First, a statistical test was carried out to evaluate the difference in surface roughness before the scaling procedure of the three materials was effected (Kruskal‐Wallis test).
Subsequently, the effect of curette material (steel and titanium) on roughness difference and roughness ratio was analyzed throughout the entire sample and within each material group, and a nonparametric test for dependent values was conducted (Wilcoxon signed‐rank test).
Finally, the roughness ratios of the three material groups were compared by means of a Kruskal‐Wallis test and a Wilcoxon signed‐rank test.
Upon completion of profilometric evaluation, representative specimens from each group were prepared for SEM evaluation to evaluate the effects of the two scaling systems on the different surfaces qualitatively.
ResultsAfter scaling procedure, the roughness profile value increased in all disks.
Classifying the full sample according to curette used, the roughness of the disks treated with a steel curette reached a higher median value than that of the titanium group.
Zirconia demonstrated the least significant increase in surface roughness.
The result was 3.
9 times of the initial value as compared to 4.
3 times for alumina and 4.
6 times for lithium disilicate.
ConclusionsComparison of profilometer readings before and after instrumentation, carried out with different hand scaling instruments, highlighted both a statistically and clinically relevant increase in material roughness.
Related Results
Surface modification of zirconia-based bioceramics for orthopedic and dental applications
Surface modification of zirconia-based bioceramics for orthopedic and dental applications
Debido a sus excelentes propiedades mecánicas y una excelente biocompatibilidad, el uso de las cerámicas de base de circona en aplicaciones dentales y ortopédicas ha crecido rápida...
Lithium Prospectivity in the Northeast German and Thuringian Ba-sins
Lithium Prospectivity in the Northeast German and Thuringian Ba-sins
Over the years many boreholes have been drilled into the Northeast German Basin (NEGB) in pursuit of the exploration of hydrocarbons. As well as gaining important information regar...
Comportamiento de la Resistencia al desgaste erosivo de recubrimientos de alúmina
Comportamiento de la Resistencia al desgaste erosivo de recubrimientos de alúmina
En este artículo se presentan los resultados de la investigación relacionada con el comportamiento experimental de recubrimientos de alúmina, obtenidos a partir de partículas de t...
Synthetization and Characterization of Yttria Stabilized Zirconia Powder from Amang Zircon Sand
Synthetization and Characterization of Yttria Stabilized Zirconia Powder from Amang Zircon Sand
Zirconia is widely used in industry as it exhibits high strength and amazing properties. However, pure zirconia powder is often unstable to be used in high temperature applications...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Effects of Veneering Ceramic and Methods on Failure Load of Veneered Zirconia
Effects of Veneering Ceramic and Methods on Failure Load of Veneered Zirconia
Background: A variety of veneering options to zirconia frameworks are now available. The purpose of this study is to evaluate the effect of veneer materials, veneering methods, cem...
Non-thermal plasma increase bond strength of zirconia to a resin cement
Non-thermal plasma increase bond strength of zirconia to a resin cement
Objective: This study investigated the influence of different surface treatments on zirconia surface energy, roughness and microshear bond strength. Material and Methods: Forty eig...
PROSPECTS OF LITHIUM EXTRACTION IN UKRAINE
PROSPECTS OF LITHIUM EXTRACTION IN UKRAINE
Background. The paper examines the prospects for the development of lithium deposits, which are determined by the demand of modern industry for lithium and lithium raw materials. T...

