A calibration approach to glandular tissue composition estimation in digital mammography
View through CrossRef
The healthy breast is almost entirely composed of a mixture of fatty, epithelial, and stromal tissues which can be grouped into two distinctly attenuating tissue types: fatty and glandular. Further, the amount of glandular tissue is linked to breast cancer risk, so an objective quantitative analysis of glandular tissue can aid in risk estimation. Highnam and Brady have measured glandular tissue composition objectively. However, they argue that their work should only be used for “relative” tissue measurements unless a careful calibration has been performed. In this work, we perform such a “careful calibration” on a digital mammography system and use it to estimate breast tissue composition of patient breasts. We imaged 0%, 50%, and 100% glandular‐equivalent phantoms of varying thicknesses for a number of clinically relevant x‐ray techniques on a digital mammography system. From these images, we extracted mean signal and noise levels and computed calibration curves that can be used for quantitative tissue composition estimation. In this way, we calculate the percent glandular composition of a patient breast on a pixelwise basis. This tissue composition estimation method was applied to 23 digital mammograms. We estimated the quantitative impact of different error sources on the estimates of tissue composition. These error sources include compressed breast height estimation error, residual scattered radiation, quantum noise, and beam hardening. Errors in the compressed breast height estimate contribute the most error in tissue composition—on the order of ±7% for a 4 cm compressed breast height. The spatially varying scattered radiation will contribute quantitatively less error overall, but may be significant in regions near the skinline. It is calculated that for a 4 cm compressed breast height, a residual scatter signal error is mitigated by approximately sixfold in the composition estimate. The error in composition due to the quantum noise, which is the limiting noise source in the system, is shown to be less than 1% glandular for most breasts.
Title: A calibration approach to glandular tissue composition estimation in digital mammography
Description:
The healthy breast is almost entirely composed of a mixture of fatty, epithelial, and stromal tissues which can be grouped into two distinctly attenuating tissue types: fatty and glandular.
Further, the amount of glandular tissue is linked to breast cancer risk, so an objective quantitative analysis of glandular tissue can aid in risk estimation.
Highnam and Brady have measured glandular tissue composition objectively.
However, they argue that their work should only be used for “relative” tissue measurements unless a careful calibration has been performed.
In this work, we perform such a “careful calibration” on a digital mammography system and use it to estimate breast tissue composition of patient breasts.
We imaged 0%, 50%, and 100% glandular‐equivalent phantoms of varying thicknesses for a number of clinically relevant x‐ray techniques on a digital mammography system.
From these images, we extracted mean signal and noise levels and computed calibration curves that can be used for quantitative tissue composition estimation.
In this way, we calculate the percent glandular composition of a patient breast on a pixelwise basis.
This tissue composition estimation method was applied to 23 digital mammograms.
We estimated the quantitative impact of different error sources on the estimates of tissue composition.
These error sources include compressed breast height estimation error, residual scattered radiation, quantum noise, and beam hardening.
Errors in the compressed breast height estimate contribute the most error in tissue composition—on the order of ±7% for a 4 cm compressed breast height.
The spatially varying scattered radiation will contribute quantitatively less error overall, but may be significant in regions near the skinline.
It is calculated that for a 4 cm compressed breast height, a residual scatter signal error is mitigated by approximately sixfold in the composition estimate.
The error in composition due to the quantum noise, which is the limiting noise source in the system, is shown to be less than 1% glandular for most breasts.
Related Results
Abstract P5-01-02: Glandular dose in contrast-enhanced dual-energy mammography
Abstract P5-01-02: Glandular dose in contrast-enhanced dual-energy mammography
Abstract
INTRODUCTION
Estimation of the Average Glandular Dose (AGD) absorbed by the breast during x-ray based examination is an established part of q...
Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract
IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
Intervention to Improve Mammography Screening at a Student-Run Free Clinic
Intervention to Improve Mammography Screening at a Student-Run Free Clinic
Background: Most late-stage breast cancer occurs in those who have never been screened. Uninsured women have lower screening rates than insured women. Student-run free clinics (SRF...
Psychological predictors of intention and avoidance of attending organized mammography screening in Norway: applying the Extended Parallel Process Model
Psychological predictors of intention and avoidance of attending organized mammography screening in Norway: applying the Extended Parallel Process Model
Abstract
Background
Mammography screening is the main method for early detection of breast cancer in Norway. Few studies have focused on psychologic...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Knowledge, attitude and uptake of mammography among female health workers in two tertiary health facilities of Sokoto state, Nigeria
Knowledge, attitude and uptake of mammography among female health workers in two tertiary health facilities of Sokoto state, Nigeria
Background: Globally, breast cancer is the most common cancer in women and early detection remains the cornerstone of breast cancer control in terms of outcome and survival. Female...
EVOLUTION IN BREAST IMAGING
EVOLUTION IN BREAST IMAGING
Evolution in breast imaging has dramatically changed and upgraded by wide variety of technologic advances from the early days of direct-exposure film mammography to xeromammograp...