Javascript must be enabled to continue!
Particle removal performance of a novel ESP type air cleaning system for indoor air quality in a subway station
View through CrossRef
Abstract
A novel electrostatic precipitation type air cleaning technology with near zero ozone emission for indoor air quality of a subway station was developed. To minimize ozone emission and achieve high particle removal performance against ultrafine particulate matters (PMs), a multi-channel charging method using soft ionization by micrometre carbon fibers and a narrow gap collection method using high electric field by thin conductive plastic sheets as a high voltage electrode were used. In this study, the novel electrostatic charging and collection technologies were applied to a real scale air cleaning system in an Air Handling Unit (AHU) with air flow rate of 950 m3/min in Yuseong Oncheon subway station with an area of 3000 m2 in Daejeon, South Korea. The particle removal performance of the demonstration system was evaluated with real suspended particles in the subway station during test period with high PM concentrations in Korea over 40 μg/m3. Particle collection efficiency, pressure drop and ozone emission were evaluated, and compared to those of the a minimum efficiency reporting value (MERV) 10 and 14 filters used in the typical subway stations in Korea. In the field researches, the developed ESP achieved over 80% of the PM collection efficiency higher than those of the filters with MERV-10 and -14, and even 10% higher efficiency against PM1.0, while generating only 10% of pressure drop and also emitting nearly zero ozone. It is concluded that a novel ESP type air cleaning system with near zero ozone emission could be a promising air cleaning method for a large indoor environment such as a subway station where polluted air with ultrafine particles flowed in with a very high flow rate.
Title: Particle removal performance of a novel ESP type air cleaning system for indoor air quality in a subway station
Description:
Abstract
A novel electrostatic precipitation type air cleaning technology with near zero ozone emission for indoor air quality of a subway station was developed.
To minimize ozone emission and achieve high particle removal performance against ultrafine particulate matters (PMs), a multi-channel charging method using soft ionization by micrometre carbon fibers and a narrow gap collection method using high electric field by thin conductive plastic sheets as a high voltage electrode were used.
In this study, the novel electrostatic charging and collection technologies were applied to a real scale air cleaning system in an Air Handling Unit (AHU) with air flow rate of 950 m3/min in Yuseong Oncheon subway station with an area of 3000 m2 in Daejeon, South Korea.
The particle removal performance of the demonstration system was evaluated with real suspended particles in the subway station during test period with high PM concentrations in Korea over 40 μg/m3.
Particle collection efficiency, pressure drop and ozone emission were evaluated, and compared to those of the a minimum efficiency reporting value (MERV) 10 and 14 filters used in the typical subway stations in Korea.
In the field researches, the developed ESP achieved over 80% of the PM collection efficiency higher than those of the filters with MERV-10 and -14, and even 10% higher efficiency against PM1.
0, while generating only 10% of pressure drop and also emitting nearly zero ozone.
It is concluded that a novel ESP type air cleaning system with near zero ozone emission could be a promising air cleaning method for a large indoor environment such as a subway station where polluted air with ultrafine particles flowed in with a very high flow rate.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Harsh Environment ESP System
Harsh Environment ESP System
Objective/Scope
When operating an Electric Submersible Pump (ESP) in a location with high installation or worker costs, the installation can cost much more than t...
Characterizing particle number size distributions and source contribution for public elementary school classrooms in bangkok
Characterizing particle number size distributions and source contribution for public elementary school classrooms in bangkok
This study characterizes particle number size distributions (PNSD) and source contributions for public elementary school classrooms in Bangkok. Using Scanning Mobility Particle Siz...
Track vibration sequence anomaly detection algorithm based on LSTM
Track vibration sequence anomaly detection algorithm based on LSTM
Subway structure monitoring obtains structure monitoring data in real time, and the obtained subway track vibration sequence exhibits obvious time series characteristics. Therefore...
Analysis of the Response Law of Station Buried Depth Change to Subway Station Under Vibration Load
Analysis of the Response Law of Station Buried Depth Change to Subway Station Under Vibration Load
In the period of rapid development of urban rail transit, the traditional transportation hub has become increasingly unable to meet the needs of people 's travel due to the lack of...
Indoor and outdoor air quality relationships modelling
Indoor and outdoor air quality relationships modelling
Particulate matter (PM) related ambient pollution has emerged as one of the most significant environmental and human health issues during the last decades. Thus, ambient PM concent...
Navigating dust storms and urban living: an analysis of particulate matter infiltration in Dubai’s residences
Navigating dust storms and urban living: an analysis of particulate matter infiltration in Dubai’s residences
In response to the growing concern of air pollution in Dubai, this study was undertaken to measure and analyze indoor and outdoor particulate matter (PM) concentrations in resident...
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
Exposure of Elderly People to Indoor Air Pollutants in Wanxia Nursing Home
The elderly residing in nursing homes are typically more advanced in age, have more health issues, and spend more time indoors than other elderly people. This study explored the in...